On the importance of electrode parameters for shaping electric field patterns generated by tDCS

被引:171
作者
Saturnino, Guilherme B. [1 ,2 ]
Antunes, Andre [2 ]
Thielscher, Axel [1 ,2 ,3 ]
机构
[1] Univ Copenhagen, Hvidovre Hosp, Danish Res Ctr Magnet Resonance, DK-2650 Hvidovre, Denmark
[2] Max Planck Inst Biol Cybernet, D-72076 Tubingen, Germany
[3] Tech Univ Denmark, Biomed Engn Sect, DK-2800 Lyngby, Denmark
关键词
Transcranial direct current stimulation; Field calculations; Finite element method; Electrode modeling; Spatial targeting; DIRECT-CURRENT STIMULATION; MOTOR CORTEX; EXCITABILITY; IMPACT; SKULL; FEM;
D O I
10.1016/j.neuroimage.2015.06.067
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Transcranial direct current stimulation (tDCS) uses electrode pads placed on the head to deliver weak direct current to the brain and modulate neuronal excitability. The effects depend on the intensity and spatial distribution of the electric field. This in turn depends on the geometry and electric properties of the head tissues and electrode pads. Previous numerical studies focused on providing a reasonable level of detail of the head anatomy, often using simplified electrode models. Here, we explore via finite element method (FEM) simulations based on a high-resolution head model how detailed electrode modeling influences the calculated electric field in the brain. We take into account electrode shape, size, connector position and conductivities of different electrode materials (including saline solutions and electrode gels). These factors are systematically characterized to demonstrate their impact on the field distribution in the brain. The goals are to assess the effect of simplified electrode models; and to develop practical rules-of-thumb to achieve a stronger stimulation of the targeted brain regions underneath the electrode pads. We show that for standard rectangular electrode pads, lower saline and gel conductivities result in more homogeneous fields in the region of interest (ROI). Placing the connector at the center of the electrode pad or farthest from the second electrode substantially increases the field strength in the ROI. Our results highlight the importance of detailed electrode modeling and of having an adequate selection of electrode pads/gels in experiments. We also advise for a more detailed reporting of the electrode montages when conducting tDCS experiments, as different configurations significantly affect the results. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:25 / 35
页数:11
相关论文
共 41 条
[11]   A finite element analysis of the effect of electrode area and inter-electrode distance on the spatial distribution of the current density in tDCS [J].
Faria, Paula ;
Hallett, Mark ;
Miranda, Pedro Cavaleiro .
JOURNAL OF NEURAL ENGINEERING, 2011, 8 (06)
[12]   The dielectric properties of biological tissues .2. Measurements in the frequency range 10 Hz to 20 GHz [J].
Gabriel, S ;
Lau, RW ;
Gabriel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2251-2269
[13]   High perimeter impedance defibrillation electrodes reduce skin burns in transthoracic cardioversion [J].
Garcia, LA ;
Pagan-Carlo, LA ;
Stone, MS ;
Kerber, RE .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (09) :1125-+
[14]   Design of electrodes and current limits for low frequency electrical impedance tomography of the brain [J].
Gilad, O. ;
Horesh, L. ;
Holder, D. S. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2007, 45 (07) :621-633
[15]   FSL [J].
Jenkinson, Mark ;
Beckmann, Christian F. ;
Behrens, Timothy Ej. ;
Woolrich, Mark W. ;
Smith, Stephen M. .
NEUROIMAGE, 2012, 62 (02) :782-790
[16]   Contribution of axonal orientation to pathway-dependent modulation of excitatory transmission by direct current stimulation in isolated rat hippocampus [J].
Kabakov, Anatoli Y. ;
Muller, Paul A. ;
Pascual-Leone, Alvaro ;
Jensen, Frances E. ;
Rotenberg, Alexander .
JOURNAL OF NEUROPHYSIOLOGY, 2012, 107 (07) :1881-1889
[17]  
Keller T., 2008, Journal of Automatic Control, V18, P35, DOI [10.2298/JAC0802035K, DOI 10.2298/JAC0802035K]
[18]  
Kronberg G, 2012, IEEE ENG MED BIO, P891, DOI 10.1109/EMBC.2012.6346075
[19]   Comparing Cortical Plasticity Induced by Conventional and High-Definition 4 x 1 Ring tDCS: A Neurophysiological Study [J].
Kuo, Hsiao-I. ;
Bikson, Marom ;
Datta, Abhishek ;
Minhas, Preet ;
Paulus, Walter ;
Kuo, Mm-Fang ;
Nitsche, Michael A. .
BRAIN STIMULATION, 2013, 6 (04) :644-648
[20]   Electrodes for high-definition transcutaneous DC stimulation for applications in drug delivery and electrotherapy, including tDCS [J].
Minhas, Preet ;
Bansal, Varun ;
Patel, Jinal ;
Ho, Johnson S. ;
Diaz, Julian ;
Datta, Abhishek ;
Bikson, Marom .
JOURNAL OF NEUROSCIENCE METHODS, 2010, 190 (02) :188-197