On the importance of electrode parameters for shaping electric field patterns generated by tDCS

被引:170
作者
Saturnino, Guilherme B. [1 ,2 ]
Antunes, Andre [2 ]
Thielscher, Axel [1 ,2 ,3 ]
机构
[1] Univ Copenhagen, Hvidovre Hosp, Danish Res Ctr Magnet Resonance, DK-2650 Hvidovre, Denmark
[2] Max Planck Inst Biol Cybernet, D-72076 Tubingen, Germany
[3] Tech Univ Denmark, Biomed Engn Sect, DK-2800 Lyngby, Denmark
关键词
Transcranial direct current stimulation; Field calculations; Finite element method; Electrode modeling; Spatial targeting; DIRECT-CURRENT STIMULATION; MOTOR CORTEX; EXCITABILITY; IMPACT; SKULL; FEM;
D O I
10.1016/j.neuroimage.2015.06.067
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Transcranial direct current stimulation (tDCS) uses electrode pads placed on the head to deliver weak direct current to the brain and modulate neuronal excitability. The effects depend on the intensity and spatial distribution of the electric field. This in turn depends on the geometry and electric properties of the head tissues and electrode pads. Previous numerical studies focused on providing a reasonable level of detail of the head anatomy, often using simplified electrode models. Here, we explore via finite element method (FEM) simulations based on a high-resolution head model how detailed electrode modeling influences the calculated electric field in the brain. We take into account electrode shape, size, connector position and conductivities of different electrode materials (including saline solutions and electrode gels). These factors are systematically characterized to demonstrate their impact on the field distribution in the brain. The goals are to assess the effect of simplified electrode models; and to develop practical rules-of-thumb to achieve a stronger stimulation of the targeted brain regions underneath the electrode pads. We show that for standard rectangular electrode pads, lower saline and gel conductivities result in more homogeneous fields in the region of interest (ROI). Placing the connector at the center of the electrode pad or farthest from the second electrode substantially increases the field strength in the ROI. Our results highlight the importance of detailed electrode modeling and of having an adequate selection of electrode pads/gels in experiments. We also advise for a more detailed reporting of the electrode montages when conducting tDCS experiments, as different configurations significantly affect the results. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:25 / 35
页数:11
相关论文
共 41 条
[1]   Effects of uniform extracellular DC electric fields on excitability in rat hippocampal slices in vitro [J].
Bikson, M ;
Inoue, M ;
Akiyama, H ;
Deans, JK ;
Fox, JE ;
Miyakawa, H ;
Jefferys, JGR .
JOURNAL OF PHYSIOLOGY-LONDON, 2004, 557 (01) :175-190
[2]   LONG-LASTING CHANGES IN LEVEL OF ELECTRICAL ACTIVITY OF CEREBRAL CORTEX PRODUCED BY POLARIZING CURRENTS [J].
BINDMAN, LJ ;
LIPPOLD, OCJ ;
REDFEARN, JW .
NATURE, 1962, 196 (4854) :584-&
[3]   The electric field in the cortex during transcranial current stimulation [J].
Cavaleiro Miranda, Pedro ;
Mekonnen, Abeye ;
Salvador, Ricardo ;
Ruffmi, Giulio .
NEUROIMAGE, 2013, 70 :48-58
[4]   Cortical surface-based analysis - I. Segmentation and surface reconstruction [J].
Dale, AM ;
Fischl, B ;
Sereno, MI .
NEUROIMAGE, 1999, 9 (02) :179-194
[5]   Modeling of the Human Skull in EEG Source Analysis [J].
Dannhauer, Moritz ;
Lanfer, Benjamin ;
Wolters, Carsten H. ;
Knoesche, Thomas R. .
HUMAN BRAIN MAPPING, 2011, 32 (09) :1383-1399
[6]   Transcranial current stimulation focality using disc and ring electrode configurations: FEM analysis [J].
Datta, Abhishek ;
Elwassif, Maged ;
Battaglia, Fortunato ;
Bikson, Marom .
JOURNAL OF NEURAL ENGINEERING, 2008, 5 (02) :163-174
[7]   Transcranial direct current stimulation in patients with skull defects and skull plates: High-resolution computational FEM study of factors altering cortical current flow [J].
Datta, Abhishek ;
Bikson, Marom ;
Fregni, Felipe .
NEUROIMAGE, 2010, 52 (04) :1268-1278
[8]   Gyri-precise head model of transcranial direct current stimulation: Improved spatial focality using a ring electrode versus conventional rectangular pad [J].
Datta, Abhishek ;
Bansal, Varun ;
Diaz, Julian ;
Patel, Jinal ;
Reato, Davide ;
Bikson, Marom .
BRAIN STIMULATION, 2009, 2 (04) :201-207
[9]   Optimized multi-electrode stimulation increases focality and intensity at target [J].
Dmochowski, Jacek P. ;
Datta, Abhishek ;
Bikson, Marom ;
Su, Yuzhuo ;
Parra, Lucas C. .
JOURNAL OF NEURAL ENGINEERING, 2011, 8 (04)
[10]   A general environment for the treatment of discrete problems and its application to the finite element method [J].
Dular, P ;
Geuzaine, C ;
Henrotte, F ;
Legros, N .
IEEE TRANSACTIONS ON MAGNETICS, 1998, 34 (05) :3395-3398