Evaluation of Acute Cardiac and Chest Wall Damage after Shocks with a Subcutaneous Implantable Cardioverter Defibrillator in Swine

被引:29
作者
Killingsworth, Cheryl R. [1 ]
Melnick, Sharon B. [1 ]
Litovsky, Silvio H. [2 ]
Ideker, Raymond E. [1 ,3 ,4 ]
Walcott, Gregory P. [1 ,3 ]
机构
[1] Univ Alabama Birmingham, Dept Med, Div Cardiovasc Dis, Cardiac Rhythm Management Lab, Birmingham, AL 35294 USA
[2] Univ Alabama Birmingham, Dept Pathol, Birmingham, AL 35294 USA
[3] Univ Alabama Birmingham, Dept Biomed Engn, Birmingham, AL 35294 USA
[4] Univ Alabama Birmingham, Dept Physiol & Biophys, Birmingham, AL 35294 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2013年 / 36卷 / 10期
关键词
implantable cardioverter defibrillator; troponin I; creatine kinase; inflammation; swine; AUTOMATIC DEFIBRILLATOR; EXTERNAL DEFIBRILLATION; MYOCARDIAL INJURY; TROPONIN-I; ARRHYTHMIAS; PREVENTION;
D O I
10.1111/pace.12173
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundA subcutaneous implantable cardioverter defibrillator (S-ICD) could ease placement and reduce complications of transvenous ICDs, but requires more energy than transvenous ICDs. Therefore we assessed cardiac and chest wall damage caused by the maximum energy shocks delivered by both types of clinical devices. MethodsDuring sinus rhythm, anesthetized pigs (38 6 kg) received an S-ICD (n = 4) and five 80-Joule (J) shocks, or a transvenous ICD (control, n = 4) and five 35-J shocks. An inactive S-ICD electrode was implanted into the same control pigs to study implant trauma. All animals survived 24hours. Troponin I and creatine kinase muscle isoenzyme (CK-MM) were measured as indicators of myocardial and skeletal muscle injury. Histopathological injury of heart, lungs, and chest wall was assessed using semiquantitative scoring. ResultsTroponin I was significantly elevated at 4hours and 24hours (22.6 +/- 16.3 ng/mL and 3.1 +/- 1.3 ng/mL; baseline 0.07 +/- 0.09 ng/mL) in control pigs but not in S-ICD pigs (0.12 +/- 0.11 ng/mL and 0.13 +/- 0.13 ng/mL; baseline 0.06 +/- 0.03 ng/mL). CK-MM was significantly elevated in S-ICD pigs after shocks (6,544 +/- 1,496 U/L and 9,705 +/- 6,240 U/L; baseline 704 +/- 398 U/L) but not in controls. Electrocardiogram changes occurred postshock in controls but not in S-ICD pigs. The myocardium and lungs were histologically normal in both groups. Subcutaneous injury was greater in S-ICD compared to controls. ConclusionAlthough CK-MM suggested more skeletal muscle injury in S-ICD pigs, significant cardiac, lung, and chest wall histopathological changes were not detected in either group. Troponin I data indicate significantly less cardiac injury from 80-J S-ICD shocks than 35-J transvenous shocks.
引用
收藏
页码:1265 / 1272
页数:8
相关论文
共 50 条
[21]   Acute superior vena cava syndrome after insertion of implantable cardioverter defibrillator [J].
Andrea Rossi ;
Massimo Baravelli ;
Paolo Cattaneo ;
Melania Romano ;
Giovanni Mariscalco ;
Daniela Imperiale ;
Maria Cristina Rossi ;
Anna Picozzi ;
Paola Dario ;
Claudio Anza ;
Annibale Sandro Montenero .
Journal of Interventional Cardiac Electrophysiology, 2008, 23 :247-249
[22]   Acute superior vena cava syndrome after insertion of implantable cardioverter defibrillator [J].
Rossi, Andrea ;
Baravelli, Massimo ;
Cattaneo, Paolo ;
Romano, Melania ;
Mariscalco, Giovanni ;
Imperiale, Daniela ;
Rossi, Maria Cristina ;
Picozzi, Anna ;
Dario, Paola ;
Anza, Claudio ;
Montenero, Annibale Sandro .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2008, 23 (03) :247-249
[23]   Shocks after implantable cardioverter-defibrillator implantation in idiopathic cardiomyopathy patients: a myocardial biopsy study [J].
Safak, Erdal ;
D'Ancona, Giuseppe ;
Schultheiss, Heinz-Peter ;
Kuehl, Uwe ;
Kische, Stephan ;
Kaplan, Hilmi ;
Ince, Hueseyin ;
Ortak, Jasmin .
HEART AND VESSELS, 2018, 33 (02) :205-211
[24]   Shocks after implantable cardioverter-defibrillator implantation in idiopathic cardiomyopathy patients: a myocardial biopsy study [J].
Erdal Safak ;
Giuseppe D´Ancona ;
Heinz-Peter Schultheiss ;
Uwe Kühl ;
Stephan Kische ;
Hilmi Kaplan ;
Hüseyin Ince ;
Jasmin Ortak .
Heart and Vessels, 2018, 33 :205-211
[25]   Inappropriate subcutaneous implantable cardioverter-defibrillator shocks due to T-wave oversensing can be prevented: Implications for management [J].
Kooiman, Kirsten M. ;
Knops, Reinoud E. ;
Nordkamp, Louise Olde ;
Wilde, Arthur A. M. ;
de Groot, Joris R. .
HEART RHYTHM, 2014, 11 (03) :426-434
[26]   Shock Efficacy of Subcutaneous Implantable Cardioverter-Defibrillator for Prevention of Sudden Cardiac Death Initial Multicenter Experience [J].
Aydin, Ali ;
Hartel, Friederike ;
Schlueter, Michael ;
Butter, Christian ;
Koebe, Julia ;
Seifert, Martin ;
Gosau, Nils ;
Hoffmann, Boris ;
Hoffmann, Matthias ;
Vettorazzi, Eik ;
Wilke, Iris ;
Wegscheider, Karl ;
Reichenspurner, Hermann ;
Eckardt, Lars ;
Steven, Daniel ;
Willems, Stephan .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (05) :913-919
[27]   Acute and Long-term Results After Contemporary Subcutaneous Implantable Cardioverter-defibrillator Implantation: A Single-center Experience [J].
Arias, Miguel A. ;
Pachon, Marta ;
Akerstrom, Finn ;
Puchol, Alberto ;
Martin-Sierra, Cristina ;
Rodriguez-Padial, Luis .
REVISTA ESPANOLA DE CARDIOLOGIA, 2018, 71 (11) :895-901
[28]   The association between defibrillation shock energy and acute cardiac damage in patients with implantable cardioverter defibrillators [J].
Ishigaki, Daisuke ;
Kutsuzawa, Daisuke ;
Arimoto, Takanori ;
Iwayama, Tadateru ;
Hashimoto, Naoaki ;
Kumagai, Yu ;
Nishiyama, Satoshi ;
Takahashi, Hiroki ;
Shishido, Tetsuro ;
Miyamoto, Takuya ;
Nitobe, Joji ;
Fukui, Akio ;
Watanabe, Tetsu ;
Kubota, Isao .
JOURNAL OF ARRHYTHMIA, 2016, 32 (06) :481-485
[29]   Optimal Medications and Appropriate Implantable Cardioverter-defibrillator Shocks in Aborted Sudden Cardiac Death Due to Coronary Spasm [J].
Sueda, Shozo ;
Kohno, Hiroaki .
INTERNAL MEDICINE, 2018, 57 (10) :1361-1369
[30]   Acute Effects of Implantable Cardioverter-Defibrillator Shocks on Biomarkers of Myocardial Injury, Apoptosis, Heart Failure, and Systemic Inflammation [J].
Brewster, Jordan ;
Sexton, Travis ;
Dhaliwal, Gary ;
Charnigo, Richard ;
Morales, Gustavo ;
Parrott, Kevin ;
Darrat, Yousef ;
Gurley, John ;
Smyth, Susan ;
Elayi, Claude S. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2017, 40 (04) :344-352