摘要
Background: Video-assisted thoracoscopic surgery (VATS) is an alternative approach to small intrapulmonary nodules, if transbronchial or percutaneous biopsy have failed. We investigated the feasibility and effectiveness of the percutaneous CT-guided placement of hook-wires to localize such nodules before video-assisted thoracoscopy. Subjects and Methods: 19 patients with new by diagnosed intrapulmonary nodules underwent CT-guided hook-wire localization by application of a X-Reidy -Set (Cook, Inc., Bjaeverskov, Denmark). The average age of the patient was 63 years (range: 19-80 years), the mean distance between the nodule and the pleura visceral was 7.58 mm (range: 0 - 25 mm) and the mean diameter was 11.58 mm (range: 5 - 25 mm). After localization, the patients underwent a VATS resection of the lesion within a mean time of 30 min (range 10 - 48 min). Results: In all cases, resection of the nodules was successful. In 4 older patients the marking was complicated by poor cooperability. At the end of manipulation the end of the hook was distanced from the nodule. But also in these cases, resection was successfully performed. 8 patients developed an asymptomatic pneumothorax: 5 of them in a minor (max. 1.5 cm rim), three of them in a moderate (max. 3 cm rim) dimension. In 4 patients, in whom the tumor was hit directly by the needle, local bleeding occurred. In one case, haemoptoe was present. In no patient did a dislocation of the hookwire-system occur. Conclusion: CT-guided placement of a hook-wire system is a simple and reasonable procedure which facilitates safe VATS resection of small pulmonary nodules.
引用
收藏
页码:202 / 207
页数:6
相关论文
共 23 条
  • [1] MIGRATION OF BREAST BIOPSY LOCALIZATION WIRE
    DAVIS, PS
    WECHSLER, RJ
    FEIG, SA
    MARCH, DE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (04) : 787 - 788
  • [2] GROSSENBACHER M, 1988, SCHWEIZ MED WSCHR, V118, P1077
  • [3] COMPLICATIONS OF THORACOSCOPY
    KAISER, LR
    BAVARIA, JE
    [J]. ANNALS OF THORACIC SURGERY, 1993, 56 (03) : 796 - 798
  • [4] CT-guided intervention by on-target laser guidance.
    Kloppel, R
    Wilke, W
    Weisse, T
    Steinecke, R
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 167 (02): : 194 - 197
  • [5] KRANSA MJ, 1996, ANN THORAC SURG, V61, P1066
  • [6] KRASNA MJ, 1994, COMPLICATIONS LAPARO, P321
  • [7] First experience with a new optical target device for CT-guided punctures.
    Krombach, GA
    Schmitz-Rode, T
    Brabrand, K
    Meyer, J
    Wildberger, JE
    Wein, BB
    Günther, RW
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (06): : 557 - 560
  • [8] LOCALIZATION OF PULMONARY NODULES BEFORE THORACOSCOPIC SURGERY - VALUE OF PERCUTANEOUS STAINING WITH METHYLENE-BLUE
    LENGLINGER, FX
    SCHWARZ, CD
    ARTMANN, W
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) : 297 - 300
  • [9] LI H, 1996, AM J ROENTGENOL, V1671, P105
  • [10] Identification of benign pulmonary nodules by needle biopsy
    Lillington, GA
    Gould, MK
    [J]. CHEST, 1998, 113 (01) : 3 - 5