Towards comprehensive characterization of Cs-137 Seeds using PRESAGE® dosimetry with optical tomography

被引:6
作者
Adamson, J. [1 ]
Yang, Y. [1 ]
Rankine, L. [1 ]
Newton, J. [1 ]
Adamovics, J. [2 ]
Craciunescu, O. [1 ]
Oldham, M. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Box 3295, Durham, NC 27710 USA
[2] Rider Univ, Dept Chem, Lawrenceville, NJ 08648 USA
来源
7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE) | 2013年 / 444卷
关键词
BRACHYTHERAPY; SYSTEM;
D O I
10.1088/1742-6596/444/1/012100
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We describe a method to directly measure the radial dose and anisotropy functions of brachytherapy sources using polyurethane based dosimeters read out with optical CT. We measured the radial dose and anisotropy functions for a Cs-137 source using a PRESAGE (R) dosimeter (9.5cm diameter, 9.2cm height) with a 0.35cm channel drilled for source placement. The dosimeter was immersed in water and irradiated to 5.3Gy at 1cm. Pre- and post-irradiation optical CT scans were acquired with the Duke Large field of view Optical CT Scanner (DLOS) and dose was reconstructed with 0.5mm isotropic voxel size. The measured radial dose factor matched the published fit to within 3% for radii between 0.5-3.0cm, and the anisotropy function matched to within 4% except for theta near 0 degrees and 180 degrees and radii >3cm. Further improvements in measurement accuracy may be achieved by optimizing dose, using the high dynamic range scanning capability of DLOS, and irradiating multiple dosimeters. Initial simulations indicate an 8 fold increase in dose is possible while still allowing sufficient light transmission during optical CT. A more comprehensive measurement may be achieved by increasing dosimeter size and flipping the source orientation between irradiations.
引用
收藏
页数:4
相关论文
共 11 条
  • [1] The dose distribution of low dose rate Cs-137 in intracavitary brachytherapy: comparison of Monte Carlo simulation, treatment planning calculation and polymer gel measurement
    Fragoso, M
    Love, PA
    Verhaegen, F
    Nalder, C
    Bidmead, AM
    Leach, M
    Webb, S
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (24) : 5459 - 5474
  • [2] Investigation of radiological properties and water equivalency of PRESAGE® dosimeters
    Gorjiara, Tina
    Hill, Robin
    Kuncic, Zdenka
    Adamovics, John
    Bosi, Stephen
    Kim, Jung-Ha
    Baldock, Clive
    [J]. MEDICAL PHYSICS, 2011, 38 (04) : 2265 - 2274
  • [3] A practical three-dimensional dosimetry system for radiation therapy
    Guo, Pengyi
    Adamovics, John
    Oldham, Mark
    [J]. MEDICAL PHYSICS, 2006, 33 (10) : 3962 - 3972
  • [4] IMAGE-ANALYSIS USING MATHEMATICAL MORPHOLOGY
    HARALICK, RM
    STERNBERG, SR
    ZHUANG, XH
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (04) : 532 - 550
  • [5] Ibbott G. S., 2010, Journal of Physics: Conference Series, V250, DOI 10.1088/1742-6596/250/1/012088
  • [6] TG-43 U1 based dosimetric characterization of model 67-6520 Cs-137 brachytherapy source
    Meigooni, Ali S.
    Wright, Clarissa
    Koona, Rafiq A.
    Awan, Shahid B.
    Granero, Domingo
    Perez-Calatayud, Jose
    Ballester, Facundo
    [J]. MEDICAL PHYSICS, 2009, 36 (10) : 4711 - 4719
  • [7] Niebanck M, 2012, MED PHYS, P39
  • [8] Oldham Mark, 2010, Journal of Physics: Conference Series, V250, DOI 10.1088/1742-6596/250/1/012064
  • [9] Pierquet M., 2010, Journal of Physics: Conference Series, V250, DOI 10.1088/1742-6596/250/1/012091
  • [10] Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
    Rivard, MJ
    Coursey, BM
    DeWerd, LA
    Hanson, WF
    Huq, MS
    Ibbott, GS
    Mitch, MG
    Nath, R
    Williamson, JF
    [J]. MEDICAL PHYSICS, 2004, 31 (03) : 633 - 674