New flow-through analytical system based on ion-selective field effect transistors with optimised calcium selective photocurable membrane for bovine serum analysis
被引:8
作者:
Abramova, N.
论文数: 0引用数: 0
h-index: 0
机构:
CSIC, Inst Microelect Barcelona IMB CNM, BioMEMS Grp, Barcelona 08193, SpainCSIC, Inst Microelect Barcelona IMB CNM, BioMEMS Grp, Barcelona 08193, Spain
Abramova, N.
[1
]
Bratov, A.
论文数: 0引用数: 0
h-index: 0
机构:
CSIC, Inst Microelect Barcelona IMB CNM, BioMEMS Grp, Barcelona 08193, SpainCSIC, Inst Microelect Barcelona IMB CNM, BioMEMS Grp, Barcelona 08193, Spain
Bratov, A.
[1
]
Ipatov, A.
论文数: 0引用数: 0
h-index: 0
机构:
CSIC, Inst Microelect Barcelona IMB CNM, BioMEMS Grp, Barcelona 08193, SpainCSIC, Inst Microelect Barcelona IMB CNM, BioMEMS Grp, Barcelona 08193, Spain
Ipatov, A.
[1
]
Levichev, S.
论文数: 0引用数: 0
h-index: 0
机构:
St Petersburg State Univ, Fac Chem, Chem Sensor Lab, St Petersburg 199034, RussiaCSIC, Inst Microelect Barcelona IMB CNM, BioMEMS Grp, Barcelona 08193, Spain
Levichev, S.
[2
]
Aris, A.
论文数: 0引用数: 0
h-index: 0
机构:
Inst Res Agr & Technol, Ruminant Dept, IRTA, Barcelona 08140, SpainCSIC, Inst Microelect Barcelona IMB CNM, BioMEMS Grp, Barcelona 08193, Spain
Aris, A.
[3
]
Rodriguez, E. M.
论文数: 0引用数: 0
h-index: 0
机构:
Inst Res Agr & Technol, Ruminant Dept, IRTA, Barcelona 08140, SpainCSIC, Inst Microelect Barcelona IMB CNM, BioMEMS Grp, Barcelona 08193, Spain
Rodriguez, E. M.
[3
]
机构:
[1] CSIC, Inst Microelect Barcelona IMB CNM, BioMEMS Grp, Barcelona 08193, Spain
[2] St Petersburg State Univ, Fac Chem, Chem Sensor Lab, St Petersburg 199034, Russia
[3] Inst Res Agr & Technol, Ruminant Dept, IRTA, Barcelona 08140, Spain
An analytical system based on ion-selective field effect transistors (ISFETs) with Ca2+ ion selective photocurable membranes is developed to offer a semiautomatic analysis of serum calcium concentration of ruminants. Optimisation of ion-sensitive membrane composition containing different copolymerised plasticizers was performed to minimise the effect of a highly lipophilic samples on sensors characteristics. To improve the system reliability the set of calibration solutions and measurement sequence were also optimised. The system was used to determine total calcium concentration in bovine sera. The precision of the ion determination was higher than reported for double charge ions with a standard deviation of about 3-7%. It is shown that the presence of coagulant in blood serum samples does not affect the determined total calcium concentration. (C) 2013 Elsevier B.V. All rights reserved.