Impact of shock energy and ventricular rhythm on the success of first shock therapy: The ALTITUDE first shock study

被引:14
作者
Cha, Yong-Mei [1 ]
Hayes, David L. [1 ]
Asirvatham, Samuel J. [1 ]
Powell, Brian D. [2 ]
Cesario, David A. [3 ]
Cao, Michael [4 ]
Gilliam, F. Roosevelt, III [5 ]
Jones, Paul W. [6 ]
Jiang, Songtao [6 ]
Saxon, Leslie A. [2 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Rochester, MN 55905 USA
[2] Carolina Hlth Syst Charlotte, Charlotte, NC USA
[3] Kaiser Permanente Orange Cty, Anaheim, CA USA
[4] Univ So Calif, Los Angeles, CA USA
[5] Cardiol Associates NE Arkansas, Jonesboro, AR USA
[6] Boston Sci Corp, Natick, MA USA
关键词
ICD; Shock; Antitachycardia pacing; Ventricular fibrillation; Ventricular tachycardia; SUDDEN CARDIAC DEATH; IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS; THRESHOLD; SAFETY; ICD;
D O I
10.1016/j.hrthm.2013.01.019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The efficacy of shock in converting different ventricular tachyarrhythmias has not been well characterized in a large natural-practice setting. OBJECTIVE To determine shock success rate by energy and ventricular rhythm in a large cohort of patients with implantable cardioverter-defibrillators. METHODS Two thousand patients with 5279 shock episodes were randomly sampled for analysis from the LATITUDE remote monitoring system. Within an episode, the rhythm preceding therapy (shock or antitachycardia pacing [ATP]) was adjudicated. Patients who died after unsuccessful implantable cardioverter-defibrillator shocks did not transmit final remote monitoring data and were not included in the study. RESULTS Of 3677 shock episodes for ventricular tachyarrhythmia, 2679 were treated with shock initially and were classified as monomorphic ventricular tachycardia (n=1544), polymorphic/monomorphic ventricular tachycardia (n=371), or ventricular fibrillation (n=764). The success rate after the first, second, and final shock averaged 90.3%, 96.4%, and 99.8%, respectively. After unsuccessful initial ATP (n=998), the first, second, and final shock was successful in 84.8%, 92.9%, and 100% of the episodes. The success rate after the first or second shock was significantly lower after failed ATP compared to shock as first therapy (both P<.001). Among episodes treated initially with shock, the success rate for monomorphic ventricular tachycardia (89.2%) when treated with energy level <= 20J was significantly higher than that for ventricular fibrillation (80.8%) (P=.04). The Level of shock energy was a significant predictor of the success of the first shock (odds ratio 1.16; 95% confidence interval 1.03-1.30; P=.013). CONCLUSIONS The success rate of first shock as first therapy is approximately 90%, but was lower after failed ATP. Programming a higher level of energy after ATP is suggested.
引用
收藏
页码:702 / 708
页数:7
相关论文
共 19 条
[1]   No benefit from defibrillation threshold testing in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial) [J].
Blatt, Joseph A. ;
Poole, Jeanne E. ;
Johnson, George W. ;
Callans, David J. ;
Raitt, Merritt H. ;
Reddy, Ramakota K. ;
Marchlinski, Francis E. ;
Yee, Raymond ;
Guarnieri, Thomas ;
Talajic, Mario ;
Wilber, David J. ;
Anderson, Jill ;
Chung, Kiyon ;
Wong, Wai Shun ;
Mark, Daniel B. ;
Lee, Kerry L. ;
Bardy, Gust H. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (07) :551-556
[2]   Changing incidence,of out-of-hospital ventricular fibrillation. 1980-2000 [J].
Cobb, LA ;
Fahrenbruch, CE ;
Olsufka, M ;
Copass, MK .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2002, 288 (23) :3008-3013
[3]   Comparison of sudden and nonsudden coronary deaths in the United States [J].
Escobedo, LG ;
Zack, MM .
CIRCULATION, 1996, 93 (11) :2033-2036
[4]  
European Heart Rhythm Association, 2006, J Am Coll Cardiol, V48, pe247, DOI 10.1016/j.jacc.2006.07.010
[5]   SAFETY OF ANTITACHYCARDIA PACING IN PATIENTS WITH IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS AND SEVERELY DEPRESSED LEFT-VENTRICULAR FUNCTION [J].
HEISEL, A ;
NEUZNER, J ;
HIMMRICH, E ;
PITSCHNER, HF ;
LIEBRICH, A ;
JUNG, J ;
SEN, S .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (01) :137-141
[6]   Systematic Review of the Incidence of Sudden Cardiac Death in the United States [J].
Kong, Melissa H. ;
Fonarow, Gregg C. ;
Peterson, Eric D. ;
Curtis, Anne B. ;
Hernandez, Adrian F. ;
Sanders, Gillian D. ;
Thomas, Kevin L. ;
Hayes, David L. ;
Al-Khatib, Sana M. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (07) :794-801
[7]   Global public health problem of sudden cardiac death [J].
Mehra, Rahul .
JOURNAL OF ELECTROCARDIOLOGY, 2007, 40 (06) :S118-S122
[8]   Scientific gaps in the prediction and prevention of sudden cardiac death [J].
Myerburg, RJ .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (07) :709-723
[9]   Evaluation of a Programming Algorithm for the Third Tachycardia Zone in a Fourth-Generation Implantable Cardioverter-Defibrillator [J].
Neglia J.J. ;
Krol R.B. ;
Giorgberidze I. ;
Mathew P. ;
Lewis C. ;
Munsif A.N. ;
Saksena S. .
Journal of Interventional Cardiac Electrophysiology, 1997, 1 (1) :49-56
[10]  
Neuzner J, 1999, AM J CARDIOL, V83, p34D