Comparison of Atmospheric Pressure Ionization for the Analysis of Heavy Petroleum Fractions with Ion Mobility-Mass Spectrometry

被引:57
作者
Farenc, Mathilde [1 ,2 ,7 ]
Corilo, Yuri E. [3 ,4 ]
Lalli, Priscila M. [3 ]
Riches, Eleanor [6 ]
Rodgers, Ryan P. [3 ,4 ,5 ]
Afonso, Carlos [1 ,2 ]
Giusti, Pierre [2 ,7 ]
机构
[1] Normandie Univ, CNRS, COBRA, INSA Rouen,UNIROUEN, F-76000 Rouen, France
[2] Joint Lab C2MC Complex Matrices Mol Characterizat, BP 27, F-76700 Gonfreville, Harfleur, France
[3] Future Fuels Inst, 1800 East Paul Dirac Dr, Tallahassee, FL 32310 USA
[4] Natl High Magnet Field Lab, 1800 East Paul Dirac Dr, Tallahassee, FL 32310 USA
[5] Florida State Univ, Dept Chem & Biochem, 95 Chieftain Way, Tallahassee, FL 32306 USA
[6] Waters Corp, Stamford Ave,Altrincham Rd, Wilmslow SK9 4AX, Cheshire, England
[7] Total Res & Technol, TOTAL Refining & Chem, BP 27, F-76700 Harfleur, France
关键词
SOLIDS ANALYSIS PROBE; CRUDE-OIL; DIESEL FUEL; MOLECULAR-WEIGHT; RESOLUTION; HYDRODESULFURIZATION; TIME; REACTIVITIES; HYDROCARBONS; COMPONENTS;
D O I
10.1021/acs.energyfuels.6b01191
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Because of its high molecular complexity, ultra high-resolution Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is used to characterize heavy petroleum distillates. However, high peak capacity can also be obtained with ion mobility-mass spectrometry (IM-MS). In this case, the additional separation dimension allows for the compensation of the lower resolving power of the time-of-flight mass analyzer. The processing and elemental composition assignments from such bidimensional IM-MS data cannot be achieved with conventional software packages. PetroOrg, a new software package, was used to compare IM-MS data sets recorded with atmospheric solid analysis probe (ASAP) and three other atmospheric pressure ionization sources. The choice of the ionization source is indeed very critical as it defines the type of compounds that can be detected from mixtures. Electrospray ionization (ESI) is very specific to polar compounds and yields relatively simple data sets that can be readily attributed to nitrogen containing compounds allowing their speciation. On the other hand, gas phase ionization methods such as APCI, APPI, and ASAP yielded valuable information concerning thiophenic species. However, in this case the IM-MS peak capacity is not sufficient to separate all isobaric species. It is worth noting that ASAP and APPI yielded similar mass spectra although the ASAP ionization mechanism is believed to be closer to that of APCI. Most likely this is due to the absence of solvent with ASAP that reinforces charge exchange processes and therefore affords low ionization discrimination such as with APPI.
引用
收藏
页码:8896 / 8903
页数:8
相关论文
共 51 条
[1]   Elucidating Molecular Structures of Nonalkylated and Short-Chain Alkyl (n < 5, (CH2)n) Aromatic Compounds in Crude Oils by a Combination of Ion Mobility and Ultrahigh-Resolution Mass Spectrometries and Theoretical Collisional Cross-Section Calculations [J].
Ahmed, Arif ;
Cho, Yunju ;
Giles, Kevin ;
Riches, Eleanor ;
Lee, Jong Wha ;
Kim, Hugh I. ;
Choi, Cheol Ho ;
Kim, Sunghwan .
ANALYTICAL CHEMISTRY, 2014, 86 (07) :3300-3307
[2]   Application of the Mason-Schamp Equation and Ion Mobility Mass Spectrometry To Identify Structurally Related Compounds in Crude Oil [J].
Ahmed, Arif ;
Cho, Yun Ju ;
No, Myoung-han ;
Koh, Jaesuk ;
Tomczyk, Nicholas ;
Giles, Kevin ;
Yoo, Jong Shin ;
Kim, Sunghwan .
ANALYTICAL CHEMISTRY, 2011, 83 (01) :77-83
[3]  
Amster IJ, 1996, J MASS SPECTROM, V31, P1325
[4]   Direct probe atmospheric pressure photoionization/atmospheric pressure chemical ionization high-resolution mass spectrometry for fast screening of flame retardants and plasticizers in products and waste [J].
Ballesteros-Gomez, A. ;
Brandsma, S. H. ;
de Boer, J. ;
Leonards, P. E. G. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (11) :2503-2512
[5]   Atmospheric Solid Analysis Probe-Ion Mobility Mass Spectrometry of Polypropylene [J].
Barrere, Caroline ;
Maire, Florian ;
Afonso, Carlos ;
Giusti, Pierre .
ANALYTICAL CHEMISTRY, 2012, 84 (21) :9349-9354
[6]   Petroleum crude oil analysis using low-temperature plasma mass spectrometry [J].
Benassi, Mario ;
Berisha, Arton ;
Romao, Wanderson ;
Babayev, Elbay ;
Roempp, Andreas ;
Spengler, Bernhard .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (07) :825-834
[8]   Ion Mobility Mass Spectrometry of Peptide Ions: Effects of Drift Gas and Calibration Strategies [J].
Bush, Matthew F. ;
Campuzano, Iain D. G. ;
Robinson, Carol V. .
ANALYTICAL CHEMISTRY, 2012, 84 (16) :7124-7130
[9]   Atmospheric pressure solid analysis probe coupled to quadrupole-time of flight mass spectrometry as a tool for screening and semi-quantitative approach of polycyclic aromatic hydrocarbons, nitro-polycyclic aromatic hydrocarbons and oxo-polycyclic aromatic hydrocarbons in complex matrices [J].
Carrizo, Daniel ;
Domeno, Celia ;
Nerin, Isabel ;
Alfaro, Pilar ;
Nerin, Cristina .
TALANTA, 2015, 131 :175-184
[10]   Soft Ionization of Saturated Hydrocarbons, Alcohols and Nonpolar Compounds by Negative-Ion Direct Analysis in Real-Time Mass Spectrometry [J].
Cody, Robert B. ;
Dane, A. John .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (03) :329-334