Heat transfer effects of chimney height, diameter, and Prandtl number

被引:8
作者
Chae, Myeong-Seon [1 ]
Chung, Bum-Jin [1 ]
机构
[1] Kyung Hee Univ, Dept Nucl Engn, Yongin 446701, Gyeonggi Do, South Korea
关键词
Heat transfer; Mass transfer; Analogy; Natural convection; Chimney effect; Prandtl number; VERTICAL PARALLEL PLATES; NATURAL-CONVECTION; CHANNEL; ENHANCEMENT;
D O I
10.1016/j.icheatmasstransfer.2015.06.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study investigates the heat transfer enhancement of a chimney system, both experimentally and numerically, by varying the height and diameter of the chimney, and the Prandtl number of the working fluid. Mass transfer experiments are carried out using a sulfuric acid and copper sulfate electroplating system based on analogy concepts. Numerical simulations are executed using FLUENT 6.3. Natural convection experiments and numerical calculations performed without a chimney showed good agreement with the Le Fevre correlation for natural convection on a vertical plate. As the chimney height is increased, the heat transfer rates are enhanced for all Prandtl numbers, but the enhancement rates decrease as the Prandtl number increases. An optimal chimney diameter is found that maximizes the heat transfer. An increase in heat input or heated length results in an additional enhancement of the heat transfer, increasing the buoyancy force. Numerical results provide visualizations of the temperature and velocity fields in the chimneys, showing their interactions and flow regimes. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:196 / 202
页数:7
相关论文
共 27 条
[1]   DIFFUSION AND CONVECTION AT ELECTRODES [J].
AGAR, JN .
DISCUSSIONS OF THE FARADAY SOCIETY, 1947, 1 :26-37
[2]   Numerical study of natural convection in vertical channels with adiabatic extensions downstream [J].
Andreozzi, A ;
Buonomo, B ;
Manca, O .
NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2005, 47 (08) :741-762
[3]  
Andreozzi A., 2001, INT J NUMER METHODS, V20, P811
[4]   Compounded natural convection enhancement in a vertical parallel-plate channel [J].
Andreozzi, Assunta ;
Campo, Antonio ;
Mancac, Oronzio .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2008, 47 (06) :742-748
[5]   Thermal management of a symmetrically heated channel-chimney system [J].
Andreozzi, Assunta ;
Buonomo, Bemardo ;
Manca, Oronzio .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2009, 48 (03) :475-487
[6]  
[Anonymous], 2006, FLUENT US GUID REL 6
[7]   NATURAL-CONVECTION IN A VERTICAL HEATED TUBE ATTACHED TO A THERMALLY INSULATED CHIMNEY OF A DIFFERENT DIAMETER [J].
ASAKO, Y ;
NAKAMURA, H ;
FAGHRI, M .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1990, 112 (03) :790-793
[8]   Thermal design of symmetrically and asymmetrically heated channel-chimney systems in natural convection [J].
Auletta, A ;
Manca, O ;
Musto, M ;
Nardini, S .
APPLIED THERMAL ENGINEERING, 2003, 23 (05) :605-621
[9]   Heat and fluid flow resulting from the chimney effect in a symmetrically heated vertical channel with adiabatic extensions [J].
Auletta, A ;
Manca, O .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2002, 41 (12) :1101-1111
[10]   Heat transfer enhancement by the chimney effect in a vertical isoflux channel [J].
Auletta, A ;
Manca, O ;
Morrone, B ;
Naso, V .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (22) :4345-4357