Visual outcomes comparison of 2 femtosecond laser platforms for laser in situ keratomileusis

被引:33
作者
Ang, Marcus [1 ,2 ]
Mehta, Jodhbir S. [1 ,2 ,3 ,4 ]
Rosman, Mohamad [1 ,2 ]
Li, Lim [1 ,2 ]
Koh, Jane C. W. [1 ]
Htoon, Hla M. [2 ]
Tan, Donald [1 ,2 ,4 ]
Chan, Cordelia [1 ]
机构
[1] Singapore Natl Eye Ctr, Singapore 168751, Singapore
[2] Singapore Eye Res Inst, Singapore, Singapore
[3] Duke NUS Grad Med Sch, Singapore, Singapore
[4] Natl Univ Hlth Syst, Singapore, Singapore
基金
新加坡国家研究基金会;
关键词
ACADEMY-OF-OPHTHALMOLOGY; FLAP CREATION; MYOPIA; LASIK; MICROKERATOME; METAANALYSIS; ASTIGMATISM;
D O I
10.1016/j.jcrs.2013.04.044
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the efficacy, predictability, and safety outcomes of 2 femtosecond laser platforms for flap creation during laser in situ keratomileusis (LASIK) for myopia and myopic astigmatism. SETTING: Singapore National Eye Centre, Singapore. DESIGN: Retrospective case review. METHODS: In this single-center multisurgeon study, patients had LASIK with flaps created using a Visumax 500 kHz or Intralase 60 kHz femtosecond laser system. Ablation was performed with the Wavelight Allegretto Eye-Q 400 Hz excimer laser in all patients. Preoperative and 3-month postoperative manifest refraction, attempted treatment spherical equivalent (SE), visual acuity, and complications were compared. RESULTS: The 500 kHz femtosecond laser group comprised 381 patients (381 eyes) and the 60 kHz femtosecond laser group, 362 patients (362 eyes). Three months postoperatively, the uncorrected distance visual acuity was 20/40 or better in 99.1% of eyes in the 60 kHz laser group and 99.4% of eyes in the 500 kHz laser group (P=.678). Regarding predictability, 98.6% of eyes and 97.4% of eyes, respectively, were within +/- 1.0 diopter of the attempted SE correction postoperatively (P=.228). The safety index was similar in the 60 kHz laser group and the 500 kHz laser group (mean 1.06 +/- 0.16 [SD] versus 1.05 +/- 0.14) (P=.321). CONCLUSION: The safety, predictability, and efficacy profiles of the 500 kHz femtosecond platform for LASIK were excellent and comparable to those of the 60 kHz platform. (C) 2013 ASCRS and ESCRS
引用
收藏
页码:1647 / 1652
页数:6
相关论文
共 16 条
  • [1] Comparison of laser in situ keratomileusis flaps created by 3 femtosecond lasers and a microkeratome
    Ahn, Hyunseok
    Kim, Jin-Kook
    Kim, Chang Kook
    Han, Gyu Heon
    Seo, Kyoung Yul
    Kim, Eung Kweon
    Kim, Tae-im
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02) : 349 - 357
  • [2] LASIK for Myopia Using the Zeiss VisuMax Femtosecond Laser and MEL 80 Excimer Laser
    Blum, Marcus
    Kunert, Kathleen
    Gille, Annika
    Sekundo, Walter
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (04) : 350 - 356
  • [3] In Vivo Real-Time Intraocular Pressure Variations during LASIK Flap Creation
    Chaurasia, Shyam S.
    Gimeno, Federico Luengo
    Tan, Kim
    Yu, Shangjuan
    Tan, Donald T.
    Beuerman, Roger W.
    Mehta, Jodhbir S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (09) : 4641 - 4645
  • [4] IntraLase Femtosecond Laser vs Mechanical Microkeratomes in LASIK for Myopia: A Systematic Review and Meta-analysis
    Chen, Shihao
    Feng, Yifan
    Stojanovic, Aleksandar
    Jankov, Mirko R., II
    Wang, Qinmei
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (01) : 15 - 24
  • [5] Comparison of eye-tracking success in laser in situ keratomileusis after flap creation with 2 femtosecond laser models
    Gimeno, Federico Luengo
    Chan, Cordelia M. L.
    Li, Lim
    Tan, Donald T. H.
    Mehta, Jodhbir S.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (03) : 538 - 543
  • [6] Femtosecond laser flap parameters and visual outcomes in laser in situ keratomileusis
    Issa, Ammar
    Al Hassany, Usama
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (04) : 665 - 674
  • [7] Overview of commercially available femtosecond lasers in refractive surgery
    Lubatschowski, Holger
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (01) : 102 - 107
  • [8] Single versus double femtosecond laser pass for incomplete laser in situ keratomileusis flap in contralateral eyes: Visual and optical outcomes
    Munoz, Gonzalo
    Albarran-Diego, Cesar
    Ferrer-Blasco, Teresa
    Javaloy, Jaime
    Garcia-Lazaro, Santiago
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (01) : 8 - 15
  • [9] Wavefront-guided LASIK for the correction of primary myopia and astigmatism - A report by the American Academy of Ophthalmology
    Schallhorn, Steven C.
    Farjo, Ayad A.
    Huang, David
    Wachler, Brian S. Boxer
    Trattler, William B.
    Tanzer, David J.
    Majmudar, Parag A.
    Sugar, Alan
    [J]. OPHTHALMOLOGY, 2008, 115 (07) : 1249 - 1261
  • [10] Laser in situ Keratomileusis for myopia and astigmatism: Safety and efficacy - A report by the American Academy of Ophthalmology
    Sugar, A
    Rapuano, CJ
    Culbertson, WW
    Huang, D
    Varley, GA
    Agapitos, PJ
    de Luise, VP
    Koch, DD
    [J]. OPHTHALMOLOGY, 2002, 109 (01) : 175 - 187