Multiscale characterization of the 3D network structure of metal carbides in a Ni superalloy by synchrotron X-ray microtomography and ptychography

被引:23
|
作者
Zhang, Zhiguo [1 ,2 ]
Khong, Jia Chuan [3 ]
Koe, Billy [2 ,4 ]
Luo, Shifeng [2 ]
Huang, Shi [2 ]
Qin, Ling [2 ]
Cipiccia, Silvia [4 ]
Batey, Darren [4 ]
Bodey, Andrew J. [4 ]
Rau, Christoph [4 ]
Chiu, Yu Lung [5 ]
Zhang, Zhu [6 ]
Gebelin, Jean-Christophe [6 ]
Green, Nick [5 ]
Mi, Jiawei [2 ]
机构
[1] Jinan Univ, Inst Adv Wear & Corros Resistant & Funct Mat, Guangzhou 510632, Peoples R China
[2] Univ Hull, Dept Engn, Kingston Upon Hull HU6 7RX, N Humberside, England
[3] UCL, Dept Med Phys Biomed Engn, London WC1E 6BT, England
[4] Diamond Light Source, Sci & Innovat Campus, Harwell OX11 0DE, Berks, England
[5] Univ Birmingham, Sch Met & Mat, High Temp Res Ctr, Birmingham B15 2TT, W Midlands, England
[6] Doncasters Grp Tech Ctr, George Baylis Rd, Droitwich WR9 9RB, England
基金
英国工程与自然科学研究理事会;
关键词
Synchrotron X-ray microtomography; Ptychography; Metal carbides; IN713LC Ni superalloy; BASE SUPERALLOY; INCONEL; 718; SOLIDIFICATION; MICROSTRUCTURE; MORPHOLOGY; EVOLUTION; TOMOGRAPHY; MECHANISM; IN713LC; GAMMA';
D O I
10.1016/j.scriptamat.2020.10.032
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Synchrotron X-ray microtomography and ptychography were used to characterize the 3D network structure, morphology and distribution of metal carbides in an as-cast IN713LC Ni superalloy. MC typed carbides were found to distribute mainly on the grain boundary between the matrix gamma and gamma' phase. The differences in solidification cooling rate had a minor influence on the volume fraction of the MC type carbides, but significantly affected the carbide size, distribution and network morphology. Depending on the local composition of the remaining liquid phase and geometric constraints, the carbides can form either spherical or strip or network morphologies. The research demonstrated clearly the advantage and technical potential of using the two complementary tomography techniques synergistically to characterize non-destructively complex multiple-phase structures in three dimensional space with a spatial resolution of similar to 30 nm. (c) 2020 Acta Materialia Inc. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/)
引用
收藏
页码:71 / 76
页数:6
相关论文
共 50 条
  • [21] Characterization of enamel caries lesions in rat molars using synchrotron X-ray microtomography
    Free, R. D.
    DeRocher, K.
    Stock, S. R.
    Keane, D.
    Scott-Anne, K.
    Bowen, W. H.
    Joester, D.
    JOURNAL OF SYNCHROTRON RADIATION, 2017, 24 : 1056 - 1064
  • [22] Novel 2D and 3D imaging of internal aerated structure of ultrasonically treated foams and cakes using X-ray tomography and X-ray microtomography
    Tan, M. C.
    Chin, N. L.
    Yusof, Y. A.
    Abdullah, J.
    JOURNAL OF FOOD ENGINEERING, 2016, 183 : 9 - 15
  • [23] Analysis of 3D Prints by X-ray Computed Microtomography and Terahertz Pulsed Imaging
    Daniel Markl
    J. Axel Zeitler
    Cecilie Rasch
    Maria Høtoft Michaelsen
    Anette Müllertz
    Jukka Rantanen
    Thomas Rades
    Johan Bøtker
    Pharmaceutical Research, 2017, 34 : 1037 - 1052
  • [24] 3D imaging of transition metals in the zebrafish embryo by X-ray fluorescence microtomography
    Bourassa, Daisy
    Gleber, Sophie-Charlotte
    Vogt, Stefan
    Yi, Hong
    Will, Fabian
    Richter, Heiko
    Shin, Chong Hyun
    Fahrni, Christoph J.
    METALLOMICS, 2014, 6 (09) : 1648 - 1655
  • [25] Strain in a silicon-on-insulator nanostructure revealed by 3D x-ray Bragg ptychography
    Chamard, V.
    Allain, M.
    Godard, P.
    Talneau, A.
    Patriarche, G.
    Burghammer, M.
    SCIENTIFIC REPORTS, 2015, 5
  • [26] 3D analysis of ceramic powder sintering by synchrotron X-ray nano-tomography
    Venkatesh, Aatreya Manjulagiri
    Bouvard, Didier
    Lhuissier, Pierre
    Villanova, Julie
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2023, 43 (06) : 2553 - 2563
  • [27] Characterization of cavitation development while tensile testing PVF2 using 3D X-ray microtomography
    Brusselle-Dupend, N.
    Rosenberg, E.
    Adrien, J.
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2011, 530 : 36 - 50
  • [28] 3D reconstruction and characterization of carbides in Ni-based high carbon alloy in a FIB-SEM system
    Bala, Piotr
    Tsyrulin, Katja
    Jaksch, Heiner
    Stepien, Milena
    INTERNATIONAL JOURNAL OF MATERIALS RESEARCH, 2015, 106 (07) : 764 - 770
  • [29] Quantifying the Influences of Carbides and Porosities on the Fatigue Crack Evolution of a Ni-Based Single-Crystal Superalloy using X-ray Tomography
    Liu, Keli
    Wang, Junsheng
    Wang, Bing
    Mao, Pengcheng
    Yang, Yanhong
    Zhou, Yizhou
    ACTA METALLURGICA SINICA-ENGLISH LETTERS, 2022, 35 (01) : 133 - 145
  • [30] Image analysis of cracks in the weld metal of a wet welded steel joint by three dimensional (3D) X-ray microtomography
    Padilla, E.
    Chawla, N.
    Silva, L. F.
    dos Santos, V. R.
    Paciornik, S.
    MATERIALS CHARACTERIZATION, 2013, 83 : 139 - 144