Precursor ion scan profiles of acylcarnitines by atmospheric pressure thermal desorption chemical ionization tandem mass spectrometry

被引:13
作者
Paglia, Giuseppe [1 ]
D'Apolito, Oceania [1 ]
Corso, Gaetano [1 ]
机构
[1] Univ Foggia, Dept Biomed Sci, I-71100 Foggia, Italy
关键词
D O I
10.1002/rcm.3799
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The fatty acyl esters of L-carnitine (acylcarnitines) are useful biomarkers for the diagnosis of some inborn errors of metabolism analyzed by liquid chromatography/tandem mass spectrometry. In this study the acylcarnitines were analyzed by atmospheric pressure thermal desorption chemical ionization using a commercial tandem mass spectrometer (APTDCI-MS/MS). The method is based on the precursor ion scan mode determination of underivatized acylcarnitines desorbed from samples by a hot desolvation gas flow and ionized by a corona pin discharge. During desorption/ionization step the temperature induces the degradation of acylcarnitines; nevertheless, the common fragment to. all acylcarnitines [MH-59](+) is useful for analyzing their profile. APTDCI parameters, including angle of collection and incidence, gas flows and temperatures, were optimized for acylcarnitines. The experiments were performed drying 2 mu L of an equimolar mixture of acylcarnitine standards on a glass slide. The specificity was evaluated by comparing product ion spectra and the precursor ion spectra of 85 m/z of acylcarnitines obtained by the APTDCI method and by electrospray ionization flow injection analysis (ESI-FIA). The method was also employed to analyze acylcarnitines extracted from a pathological dried blood spot and a control. The method enables analysis of biological samples and recognition of some acylcarnitines that are diagnostic markers of inherited metabolic diseases. The intrinsic high-throughput analysis of the ambient desorption ionization methods offers a new opportunity either for its potential application in clinical chemistry and for the expanded screening of some inborn errors of metabolism. Copyright (C) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:3809 / 3815
页数:7
相关论文
共 22 条
[1]  
ANDRADE FJ, 2007, P 55 ASMS C MASS SPE
[2]   Use of tandem mass spectrometry for multianalyte screening of dried blood specimens from newborns [J].
Chace, DH ;
Kalas, TA ;
Naylor, EW .
CLINICAL CHEMISTRY, 2003, 49 (11) :1797-1817
[3]  
Chace DH, 1997, CLIN CHEM, V43, P2106
[4]   Thermal production and reactions of organic ions at atmospheric pressure [J].
Chen, Hao ;
Zheng Ouyang ;
Cooks, R. Graham .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2006, 45 (22) :3656-3660
[5]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[6]   Ambient mass spectrometry [J].
Cooks, RG ;
Ouyang, Z ;
Takats, Z ;
Wiseman, JM .
SCIENCE, 2006, 311 (5767) :1566-1570
[7]   Neutral loss analysis of amino acids by desorption electrospray ionization using an unmodified tandem quadrupole mass spectrometer [J].
Corso, Gaetano ;
Paglia, Giuseppe ;
Garofalo, Daniela ;
D'Apolito, Oceania .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (23) :3777-3784
[8]  
Ford MJ, 2004, RAPID COMMUN MASS SP, V18, P1303, DOI 10.1002/rcm.1486
[9]   Desorption sonic spray ionization for (high) voltage-free ambient mass spectrometry [J].
Haddad, Renato ;
Sparrapan, Regina ;
Eberlin, Marcos N. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (19) :2901-2905
[10]   Analysis of solids, liquids, and biological tissues using solids probe introduction at atmospheric pressure on commercial LC/MS instruments [J].
McEwen, CN ;
McKay, RG ;
Larsen, BS .
ANALYTICAL CHEMISTRY, 2005, 77 (23) :7826-7831