MR Tracking of Iron-labeled Glass Radioembolization Microspheres during Transcatheter Delivery to Rabbit VX2 Liver Tumors: Feasibility Study

被引:38
作者
Gupta, Twinkle [1 ]
Virmani, Sumeet [1 ]
Neidt, Tod M. [1 ]
Szolc-Kowalska, Barbara [1 ]
Sato, Kent T. [1 ]
Ryu, Robert K. [1 ]
Lewandowski, Robert J. [1 ]
Gates, Vanessa L. [1 ]
Woloschak, Gayle E. [1 ]
Salem, Riad [1 ]
Omary, Reed A. [1 ]
Larson, Andrew C. [1 ]
机构
[1] Northwestern Univ, Dept Pathol, Chicago, IL 60611 USA
关键词
D O I
10.1148/radiol.2491072027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively test the hypothesis that iron labeling of radioembolization microspheres permits their visualization by using magnetic resonance (MR) imaging for in vivo tracking during transcatheter delivery to liver tumors. Materials and Methods: All experiments were approved by the Institutional Animal Care and Use Committee. Phantom studies were performed to quantify microsphere relaxivity and volume susceptibility properties and compare image contrast patterns resulting from aggregate deposition of unlabeled and iron-labeled microspheres. In seven rabbits in which nine VX2 liver tumors were implanted, T2*-weighted gradient-echo (GRE) MR images with negative image contrast (NC), white-marker (WM) GRE images with positive image contrast (PC), and on-resonance water-suppression turbo spin-echo (SE) images with PC were obtained before and after catheter-directed administration of microspheres into the hepatic artery. During each injection, serial GRE acquisitions were performed for real-time visualization of microsphere delivery. Contrast-to-noise ratios (CNRs) were measured between regions of microsphere accumulation and regions of normal liver parenchyma that demonstrated no apparent microsphere accumulation. Pre- and postinjection CNR measurements at identical spatial positions were compared by using paired t test (alpha = .05). Results: Conventional microspheres did not produce detectable image contrast in phantoms. Iron-labeled microspheres produced susceptibility-induced dipole patterns with spatial extent of image contrast increasing with increasing microsphere dose. Real-time image series depicted both preferential delivery to tumor tissues and nontargeted delivery to adjacent organs. T2*-weighted GRE, WM GRE, and on-resonance water-suppression turbo SE each permitted in vivo visualization of the microsphere deposition, with postinjection CNR values (mean, 14.29 +/- 3.98 [standard deviation], 1.87 +/- 0.93, and 19.30 +/- 8.72, respectively) significantly greater than corresponding preinjection CNR values (mean, 2.02 +/- 4.65, 0.02 +/- 0.27, 0.85 +/- 2.65, respectively) (P < .05). Conclusion: Microsphere tracking during radioembolization may permit real-time verification of delivery and detection of extrahepatic shunting. (C) RSNA, 2008
引用
收藏
页码:845 / 854
页数:10
相关论文
共 21 条
[11]  
Salem R, 2005, J VASC INTERV RADIOL, V16, P1627
[12]   Yttrium-90 microspheres: Radiation therapy for unresectable liver cancer [J].
Salem, R ;
Thurston, KG ;
Carr, BI ;
Goin, JE ;
Geschwind, JFH .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (09) :S223-S229
[13]   Radioembolization with yttrium-90 microspheres: A state-of-the-art brachytherapy treatment for primary and secondary liver malignancies - Part 3: Comprehensive literature review and future direction [J].
Salem, Riad ;
Thurston, Kenneth G. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (10) :1571-1593
[14]   Radioembolization with 90Yttrium microspheres:: A state-of-the-art brachytherapy treatment for primary and secondary liver malignancies -: Part 2:: Special topics [J].
Salem, Riad ;
Thurston, Kenneth G. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (09) :1425-1439
[15]   Radioembolization with 90Yttrium microspheres:: A state-of-the-art brachytherapy treatment for primary and secondary liver malignancies part 1:: Technical and methodologic considerations [J].
Salem, Riad ;
Thurston, Kenneth G. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (08) :1251-1278
[16]   The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds [J].
Schenck, JF .
MEDICAL PHYSICS, 1996, 23 (06) :815-850
[17]   Internal radiation therapy of liver tumors: Qualitative and quantitative magnetic resonance imaging of the biodistribution of holmium-loaded microspheres in animal models [J].
Seppenwoolde, JH ;
Nijsen, JFW ;
Bartels, LW ;
Zielhuis, SW ;
Schip, ADV ;
Bakker, CJG .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (01) :76-84
[18]   Passive tracking exploiting local signal conservation: The white marker phenomenon [J].
Seppenwoolde, JH ;
Viergever, MA ;
Bakker, CJG .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (04) :784-790
[19]   In vivo cellular imaging of lymphocyte tracking by MRI:: A tumor model approach to cell-based anticancer therapy [J].
Smirnov, Pierre ;
Lavergne, Elise ;
Gazeau, Florence ;
Lewin, Maite ;
Boissonnas, Alexandre ;
Doan, Bich-Thuy ;
Gillet, Brigitte ;
Combadiere, Christophe ;
Combadiere, Behazine ;
Clement, Olivier .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (03) :498-508
[20]   Positive contrast visualization of iron oxide-labeled stem cells using inversion-recovery with ON-Resonant water suppression (IRON) [J].
Stuber, Matthias ;
Gilson, Wesley D. ;
Schaer, Michael ;
Kedziorek, Dorota A. ;
Hofmann, Lawrence V. ;
Shah, Saurabh ;
Vonken, Evert-Jan ;
Bulte, Jeff W. M. ;
Kraitchman, Dara L. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) :1072-1077