Wireless sensor networks for temperature and humidity monitoring within concrete structures

被引:109
作者
Barroca, Norberto [1 ]
Borges, Luis M. [1 ]
Velez, Fernando J. [1 ]
Monteiro, Filipe [2 ]
Gorski, Marcin [2 ,3 ]
Castro-Gomes, Joao [2 ]
机构
[1] Univ Beira Interior, Inst Telecomunicacoes, Dept Electromech Engn, P-6201001 Covilha, Portugal
[2] Univ Beira Interior, C MADE, Ctr Mat & Bldg Technol, Dept Civil Engn & Architecture, P-6201001 Covilha, Portugal
[3] Silesian Tech Univ, Dept Struct Engn, Gliwice, Poland
关键词
Wireless sensor networks; Structural health monitoring; Concrete; Sensor; Temperature; Humidity; SYSTEMS;
D O I
10.1016/j.conbuildmat.2012.11.087
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the development of an automatic wireless sensor monitoring system for civil engineering structures. The objective is to provide a solution to measure both temperature and humidity inside a concrete structure. The research has been focused in the early age and curing phase period. Four solutions have been addressed. The first one involves the use of a negative temperature coefficient (NTC) thermistor and an IRIS mote allowing for the creation of an IEEE 802.15.4 network. However, the results have shown that the sensor measurements present a 5 C standard deviation between the actual and the experimental values. The second one considers the use of the SHT15 (humidity/temperature) sensor, together with the PIC18F4680 microcontroller or the Arduino platform. The third solution involves the use of the SHT21S (humidity/temperature) sensor and the eZ430-RF2500 wireless development tool platform for the MSP430 microcontroller. In this case, the temperature readings were successfully performed for the first 16 h, while the humidity values were successfully obtained for the first 24 h of the experiment. Although the set of measured values is very promising for the SHT15 and SHT21S sensors, both sensors have stopped working after some time, showing that direct contact between the sensor and the concrete alkaline environment causes its breakdown. Finally, the fourth solution considers both the SHT15 and SHT21S sensors completely shielded allowing for the creation of a long-term solution. As, the SHT15 and SHT12S sensors have not been affected by the alkaline environment for more than two months of operation, enabling real-time and continuous monitoring with almost non-intrusive tiny devices, the potential of applying the proposed inexpensive wireless sensor network approach is verified. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1156 / 1166
页数:11
相关论文
共 14 条
[1]  
Buenfeld N., 2008, INTELLIGENT MONITORI, P150
[2]   Editorial: Automated monitoring of concrete structures - research opportunities [J].
Buenfeld, N. R. .
MAGAZINE OF CONCRETE RESEARCH, 2011, 63 (02) :79-80
[3]   Implementing RFIC and sensor technology to measure temperature and humidity inside concrete structures [J].
Chang, Chih-Yuan ;
Hung, San-Shan .
CONSTRUCTION AND BUILDING MATERIALS, 2012, 26 (01) :628-637
[4]  
Cruz PJS, 2006, SENSOR MATER, V18, P283
[5]   Development of an embeddable sensor to monitor the corrosion process of new and existing reinforced concrete structures [J].
Duffo, Gustavo S. ;
Farina, Silvia B. .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (08) :2746-2751
[6]   Miniature Mobile Sensor Platforms for Condition Monitoring of Structures [J].
Friedrich, Markus ;
Dobie, Gordon ;
Chan, Chung Chee ;
Pierce, S. Gareth ;
Galbraith, Walter ;
Marshall, Stephen ;
Hayward, Gordon .
IEEE SENSORS JOURNAL, 2009, 9 (11) :1439-1448
[7]  
Inaudi D., 2009, 4 INT C STRUCT HLTH
[8]  
Jurdak R, 2007, SIGNALS COMMUN TECHN, P1, DOI 10.1007/978-0-387-39023-9
[9]   Examples of reinforcement corrosion monitoring by embedded sensors in concrete structures [J].
Martinez, I. ;
Andrade, C. .
CEMENT & CONCRETE COMPOSITES, 2009, 31 (08) :545-554
[10]  
McCarter W.J., 2010, 2 INT C DUR CONCR ST