Variable Lung Density Consideration in Attenuation Correction of Whole-Body PET/MRI

被引:38
作者
Marshall, Harry R. [1 ,2 ]
Prato, Frank S. [3 ]
Deans, Lela
Theberge, Jean [3 ]
Thompson, R. Terry [3 ]
Stodilka, Robert Z. [4 ]
机构
[1] Lawson Hlth Res Inst, Dept Imaging, Imaging Program, London, ON N6A 4V2, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] St Josephs Hlth Ctr, Dept Diagnost Imaging, London, ON, Canada
[4] London Hlth Sci Ctr, London, ON, Canada
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
PET/MRI; attenuation correction; lung density; segmentation; whole-body imaging; PET; SEGMENTATION; QUANTITATION; PERFUSION; SYSTEMS; TISSUE;
D O I
10.2967/jnumed.111.098350
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Present attenuation-correction algorithms in whole-body PET/MRI do not consider variations in lung density, either within or between patients; this may adversely affect accurate quantification. In this work, a technique to incorporate patient-specific lung density information into MRI-based attenuation maps is developed and compared with an approach that assumes uniform lung density. Methods: Five beagles were scanned with F-18-FDG PET/CT and MRI. The relationship between MRI and CT signal in the lungs was established, allowing the prediction of attenuation coefficients from MRI. MR images were segmented into air, lung, and soft tissue and converted into attenuation maps, some with constant lung density and some with patient-specific lung densities. The resulting PET images were compared by both global metrics of quantitative fidelity (accuracy, precision, and root mean squared error) and locally with relative error in volumes of interest. Results: A linear relationship was established between MRI and CT signal in the lungs. Constant lung density attenuation maps did not perform as well as patient-specific lung density attenuation maps, regardless of what constant density was chosen. In particular, when attenuation maps with patient-specific lung density were used, precision, accuracy, and root mean square error improved in lung tissue. In volumes of interest placed in the lungs, relative error was significantly reduced from a minimum of 12% to less than 5%. The benefit extended to tissues adjacent to the lungs but became less important as distance from the lungs increased. Conclusion: A means of using MRI to infer patient-specific attenuation coefficients in the lungs was developed and applied to augment whole-body MRI-based attenuation maps. This technique has been shown to improve the quantitative fidelity of PET images in the lungs and nearby tissues, compared with an approach that assumes uniform lung density.
引用
收藏
页码:977 / 984
页数:8
相关论文
共 50 条
  • [41] Attenuation Correction Approaches for Serotonin Transporter Quantification With PET/MRI
    Rischka, Lucas
    Gryglewski, Gregor
    Berroteran-Infante, Neydher
    Rausch, Ivo
    James, Gregory Miles
    Kloebl, Manfred
    Sigurdardottir, Helen
    Hartenbach, Markus
    Hahn, Andreas
    Wadsak, Wolfgang
    Mitterhauser, Markus
    Beyer, Thomas
    Kasper, Siegfried
    Prayer, Daniela
    Hacker, Marcus
    Lanzenberger, Rupert
    FRONTIERS IN PHYSIOLOGY, 2019, 10
  • [42] Optimized Whole-Body PET MRI Sequence Workflow in Pediatric Hodgkin Lymphoma Patients
    Georgi, Thomas W.
    Stoevesandt, Dietrich
    Kurch, Lars
    Bartelt, Joerg M.
    Hasenclever, Dirk
    Dittmann, Helmut
    Ferda, Jiri
    Francis, Peter
    Franzius, Christiane
    Furth, Christian
    Graefe, Daniel
    Gussew, Alexander
    Huellner, Martin
    Menezes, Leon J.
    Mustafa, Mona
    Stegger, Lars
    Umutlu, Lale
    Zoephel, Klaus
    Zucchetta, Pietro
    Koerholz, Dieter
    Sabri, Osama
    Mauz-Koerholz, Christine
    Kluge, Regine
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64 (01) : 96 - 101
  • [43] Cardiovascular whole-body MRI
    Kramer, Harald
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 70 (03) : 418 - 423
  • [44] A Beyond Whole-Body Imaging Advanced Imaging Techniques of PET/MRI
    Barnwell, James
    Raptis, Constantine A.
    McConathy, Jonathan E.
    Laforest, Richard
    Siegel, Barry A.
    Woodard, Pamela K.
    Fowler, Kathryn
    CLINICAL NUCLEAR MEDICINE, 2015, 40 (02) : E88 - E95
  • [45] Quantitative analysis of MRI-guided attenuation correction techniques in time-of-flight brain PET/MRI
    Mehranian, Abolfazl
    Arabi, Hossein
    Zaidi, Habib
    NEUROIMAGE, 2016, 130 : 123 - 133
  • [46] Improved clinical workflow for simultaneous whole-body PET/MRI using high-resolution CAIPIRINHA-accelerated MR-based attenuation correction
    Freitag, Martin T.
    Fenchel, Matthias
    Baumer, Philipp
    Heusser, Thorsten
    Rank, Christopher M.
    Kachelriess, Marc
    Paech, Daniel
    Kopka, Klaus
    Bickelhaupt, Sebastian
    Dimitrakopoulou-Strauss, Antonia
    Maier-Hein, Klaus
    Floca, Ralf
    Ladd, Mark E.
    Schlemmer, Heinz -Peter
    Maier, Florian
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 96 : 12 - 20
  • [47] Whole-Body [18F]-FDG-PET/MRI for Oncology: A Consensus Recommendation
    Umutlu, Lale
    Beyer, Thomas
    Grueneisen, Johannes Stefan
    Rischpler, Christoph
    Quick, Harald H.
    Veit-Haibach, Patrick
    Eiber, Matthias
    Purz, Sandra
    Antoch, Gerald
    Gatidis, Sergios
    Nikolaou, Konstantin
    Schaefer, Juergen F.
    Rausch, Ivo
    Herrmann, Ken
    Herrmann, K.
    Krause, B. J.
    Schoenberg, S. O.
    Umutlu, L.
    Anton, F.
    Antoch, G.
    Hacker, M.
    Krause, B. J.
    Luster, M.
    Neumann, S.
    Schoenberg, S. O.
    Vorwerk, D.
    Schoenberg, Stefan
    Vorwerk, Dierk
    Antoch, Gerald
    Anton, Frank
    Neumann, Stefan
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2019, 191 (04): : 289 - 297
  • [48] Whole-Body [18F]-FDG-PET/MRI for Oncology: A Consensus Recommendation
    Umutlu, Lale
    Beyer, Thomas
    Grueneisen, Johannes Stefan
    Rischpler, Christoph
    Quick, Harald H.
    Veit-Halbach, Patrick
    Eiber, Matthias
    Purz, Sandra
    Antoch, Gerald
    Gatidis, Sergios
    Nikolaou, Konstantin
    Schaefer, Jurgen F.
    Rausch, Ivo
    Herrmann, Ken
    Herrmann, K.
    Krause, B. J.
    Schoenberg, S. O.
    Umutlu, L.
    Anton, F.
    Antoch, G.
    Hacker, M.
    Krause, B. J.
    Luster, M.
    Neumann, S.
    Schoenberg, S. O.
    Vorwerk, D.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2019, 58 (02): : 68 - 76
  • [49] Assessment of the extent of metastases of gastrointestinal carcinoid tumors using whole-body PET, CT, MRI, PET/CT and PET/MRI
    Seemann, MD
    Meisetschlaeger, G
    Gaa, J
    Rummeny, EJ
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2006, 11 (02) : 58 - 65
  • [50] The synergistic effect of PET/MRI in whole-body oncologic imaging: an Expert Review
    Felipe S. Furtado
    Mina Hesami
    Shaunagh Mcdermott
    Harshad Kulkarni
    Alexander Herold
    Onofrio A. Catalano
    Clinical and Translational Imaging, 2023, 11 : 351 - 364