Continuous flow fluorescence based immunosensor for the detection of explosives and environmental pollutants

被引:3
|
作者
Charles, PT
Bart, JC
Judd, LL
Gauger, PR
Ligler, FS
Kusterbeck, AW
机构
关键词
immunosensor; fluorescence; antibody; explosives; environmental; pollutants; TNT; RDX; PCBs;
D O I
10.1117/12.276137
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A continuous flow fluorescence based immunosensor has been developed at the Naval Research Laboratory as an inexpensive, field portable device to detect environmental pollutants. Detection of environmental pollutants such as explosives [e.g. trinitrotoluene (TNT) and hexahydro-1,3,5 trinitro-1,3,5-triazine (RDX)] and polychlorinated biphenyls (PCBs) have been achieved at low level concentrations. The continuous now immunosensor (CFI) employs antibodies as recognition elements for specific antigens. Antibodies specific for the environmental pollutants of interest are covalently immobilized on a solid support matrix. Subsequent saturation of the antibody-support complex with a fluorescence analog (ie. cyanine dye) of the pollutant completes the sensor matrix. The derivatized matrix is prepacked into a micro column with a continuous flow stream of buffer that removes nonspecifically bound fluorescent analog. After a stable baseline is obtained sample injections of the desired pollutant (PCBs, TNT, RDX, etc.) into the now stream displaces the fluorescence analog from the immobilized antibody on the solid support. A signal response over background from the displaced fluorescence analog is measured and integrated by an in-line fluorometer. Dose response curves reveal the lowest limit of detection for TNT and RDX is 20 ppb (parts-per-billion). Detection limits for PCBs is slightly higher at 1.0 ppm (part-per-million). Results from field trials conducted at two military bases, Umatilla Army Depot (Hermiston, OR) and Site F and A at Naval SUBASE Banger (Bangor, WA) demonstrated the capabilities of the Immunosensor in performing on-site field analysis in groundwater and soil leachate matrices.
引用
收藏
页码:80 / 87
页数:8
相关论文
共 50 条
  • [1] CONTINUOUS-FLOW IMMUNOSENSOR FOR DETECTION OF EXPLOSIVES
    WHELAN, JP
    KUSTERBECK, AW
    WEMHOFF, GA
    BREDEHORST, R
    LIGLER, FS
    ANALYTICAL CHEMISTRY, 1993, 65 (24) : 3561 - 3565
  • [2] Detection of explosives in groundwater samples using a continuous flow immunosensor
    Bart, JC
    Hoffman, KE
    Judd, LL
    Wilkens, AM
    Kusterbeck, AW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 211 : 15 - ENVR
  • [3] Non-aerosol detection of explosives with a continuous flow immunosensor
    Shriver-Lake, LC
    Charles, PT
    Kusterbeck, AW
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (03) : 550 - 555
  • [4] Non-aerosol detection of explosives with a continuous flow immunosensor
    Lisa C. Shriver-Lake
    Paul T. Charles
    Anne W. Kusterbeck
    Analytical and Bioanalytical Chemistry, 2003, 377 : 550 - 555
  • [5] Explosives detection in soil using a field-portable continuous flow immunosensor
    Gauger, PR
    Holt, DB
    Patterson, CH
    Charles, PT
    Shriver-Lake, L
    Kusterbeck, AW
    JOURNAL OF HAZARDOUS MATERIALS, 2001, 83 (1-2) : 51 - 63
  • [6] Continuous flow immunosensor for atrazine detection
    Vianello, F
    Signor, L
    Pizzariello, A
    Di Paolo, ML
    Scarpa, M
    Hock, B
    Giersch, T
    Rigo, A
    BIOSENSORS & BIOELECTRONICS, 1998, 13 (01): : 45 - 53
  • [7] Portable flow immunosensor for detecting drugs and explosives
    Kusterbeck, AW
    Gauger, PR
    Charles, PT
    CHEMISTRY- AND BIOLOGY-BASED TECHNOLOGIES FOR CONTRABAND DETECTION, 1997, 2937 : 191 - 196
  • [8] Preparation of Carbon Quantum Dots for Fluorescence Detection of Environmental Pollutants
    Zhang, Jingwei
    Yin, Han
    Shen, You
    Bai, Maojuan
    Wan, Jun
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2019, 19 (09) : 5522 - 5528
  • [9] FIBER-FLUORESCENCE IMMUNOSENSOR BASED ON EVANESCENT WAVE DETECTION
    EENINK, RG
    DEBRUIJN, HE
    KOOYMAN, RPH
    GREVE, J
    ANALYTICA CHIMICA ACTA, 1990, 238 (02) : 317 - 321
  • [10] Carbon nanotubes-based chemiresistive immunosensor for small molecules: Detection of nitroaromatic explosives
    Park, Miso
    Cella, Lakshmi N.
    Chen, Wilfred
    Myung, Nosang V.
    Mulchandani, Ashok
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (04): : 1297 - 1301