Automatic Ballistocardiogram (BCG) Beat Detection Using a Template Matching Approach

被引:52
作者
Shin, J. H. [1 ]
Choi, B. H. [1 ]
Lim, Y. G. [2 ]
Jeong, D. U. [3 ]
Park, K. S. [3 ]
机构
[1] Seoul Natl Univ, Dept Biomed Engn, Seoul, South Korea
[2] Sangji Univ, Dept Biomed Engn, Wonju, South Korea
[3] Seoul Natl Univ, Coll Med, Seoul, South Korea
来源
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8 | 2008年
关键词
Ballistocardiogram; beat detection; template matching; unconstrained monitoring system; ubiquitous healthcare;
D O I
10.1109/IEMBS.2008.4649363
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper suggests a beat detection method for ballistocardiogram (BCG) from an unconstrained cardiac signal monitoring devices. A fiducial peak point of BCG is an I-J-K complex which corresponds with ventricle contraction and Electrocardiogram (ECG) QRS complex. The goal of the method is extraction of J peak without ECG synchronization. The detection method is based on a "template matching" rule evaluated using a correlation function in a local moving-window procedure. The total beat detection algorithm operates in two stages, template definition stage and beat detection stage with defined template in previous stage. In the first stage, the BCG template is constructed by the expert with an empirical analysis of BCG signal and measurement device. In the second stage, the correlation function calculates an accuracy of template with BCG signal using a local moving-window. The data analysis has been performed on the subjects tested at Seoul National University Hospital Sleep Medicine Center and presents 95.16% of sensitivity and 94.76% of positive predictivity value for the J peak detection.
引用
收藏
页码:1144 / +
页数:2
相关论文
共 8 条
[1]   Air mattress sensor system with balancing tube for unconstrained measurement of respiration and heart beat movements [J].
Chee, Y ;
Han, J ;
Youn, J ;
Park, K .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (04) :413-422
[2]   Respiratory monitoring using an air-mattress system [J].
Chow, P ;
Nagendra, G ;
Abisheganaden, J ;
Wang, YT .
PHYSIOLOGICAL MEASUREMENT, 2000, 21 (03) :345-354
[3]   Critical review of non-invasive respiratory monitoring in medical care [J].
Folke, M ;
Cernerud, L ;
Ekström, M ;
Hök, B .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2003, 41 (04) :377-383
[4]  
HERNANDEZ L, PHYSL MEAS, V16, P161
[5]  
Jacobs JL, 2004, P ANN INT IEEE EMBS, V26, P2223
[6]   A 'smart' bed for non-intrusive monitoring of patient physiological factors [J].
Spillman, WB ;
Mayer, M ;
Bennett, J ;
Gong, J ;
Meissner, KE ;
Davis, B ;
Claus, RO ;
Muelenaer, AA ;
Xu, X .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (08) :1614-1620
[7]   Methodologic standards for the development of clinical decision rules in emergency medicine [J].
Stiell, IG ;
Wells, GA .
ANNALS OF EMERGENCY MEDICINE, 1999, 33 (04) :437-447
[8]   Noncontact method for sleep stage estimation [J].
Watanabe, T ;
Watanabe, K .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (10) :1735-1748