Management of brain AVM procedural hemorrhagic complication by the "security" catheter technique

被引:13
作者
Abud, Daniel Giansante [1 ]
Abud, Thiago Giansante [1 ]
Nakiri, Guilherme Seizem [1 ]
机构
[1] Univ Sao Paulo, Med Sch Ribeirao Preto, Dept Internal Med, Div Intervent Neuroradiol, BR-14049 Ribeirao Preto, SP, Brazil
关键词
Brain arteriovenous malformations; Endovascular treatment; Complications; CEREBRAL ARTERIOVENOUS-MALFORMATIONS; BUTYL CYANOACRYLATE EMBOLIZATION; ONYX; MULTICENTER; TRIAL;
D O I
10.1016/j.neurad.2012.03.010
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Since the introduction of Onyx as a liquid embolic agent for the treatment of brain arteriovenous malformation (AVM), higher endovascular cure rates have been achieved. This may be partially attributed to its non-adhesive property, which allows longer intranidal progression of the embolic agent before solidification. However, Onyx reflux around the microcatheter can form a highly viscous plug, thereby constraining the microcatheter during its retrieval. Also, during the maneuver, arterial stretching can lead to vascular rupture and result in acute bleeding, a potentially fatal complication that demands immediate treatment. This report describes a new treatment strategy for the rapid management of such a complication. The technique consists of the placement of a second microcatheter about 2 cm proximal to the AVM nidus in the same artery containing the intranidal microcatheter. After conclusion of embolization, if rupture occurs during intranidal microcatheter retrieval, the second microcatheter that is already in place can promptly be used to control the bleeding. (C) 2012 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:45 / 49
页数:5
相关论文
共 10 条
[1]   Treatment of Brain Arteriovenous Malformations by Double Arterial Catheterization with Simultaneous Injection of Onyx: Retrospective Series of 17 Patients [J].
Abud, D. G. ;
Riva, R. ;
Nakiri, G. S. ;
Padovani, F. ;
Khawaldeh, M. ;
Mounayer, C. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) :152-158
[2]   A prospective, multicenter, randomized trial of the Onyx liquid embolic system and N-butyl cyanoacrylate embolization of cerebral arteriovenous malformations [J].
Loh, Yince ;
Duckwiler, Gary R. .
JOURNAL OF NEUROSURGERY, 2010, 113 (04) :733-741
[3]   Brain Arteriovenous Malformation Treatment Using a Combination of Onyx and a New Detachable Tip Microcatheter, SONIC: Short-Term Results [J].
Maimon, S. ;
Strauss, I. ;
Frolov, V. ;
Margalit, N. ;
Ram, Z. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (05) :947-954
[4]   Effect of liquid embolic agents on Gamma Knife surgery dosimetry for arteriovenous malformations Clinical article [J].
Mamalui-Hunter, Maria ;
Jiang, Thomas ;
Rich, Keith M. ;
Derdeyn, Colin P. ;
Drzymala, Robert E. .
JOURNAL OF NEUROSURGERY, 2011, 115 (02) :364-370
[5]  
Mounayer C, 2007, AM J NEURORADIOL, V28, P518
[6]  
PELZ DM, 1988, AM J NEURORADIOL, V9, P757
[7]  
Purdy P, 2002, AM J NEURORADIOL, V23, P748
[8]  
Richling Bernd, 2006, Neurosurgery, V59, pS148
[9]   Endovascular treatment of brain arteriovenous malformations with prolonged intranidal Onyx injection technique: long-term results in 350 consecutive patients with completed endovascular treatment course [J].
Saatci, Isil ;
Geyik, Serdar ;
Yavuz, Kivilcim ;
Cekirge, H. Saruhan .
JOURNAL OF NEUROSURGERY, 2011, 115 (01) :78-88
[10]  
Weber W, 2007, AM J NEURORADIOL, V28, P371