Optical Coherence Tomography Findings in Bioresorbable Vascular Scaffolds Thrombosis

被引:52
作者
Cuculi, Florim [1 ]
Puricel, Serban [2 ]
Jamshidi, Peiman [1 ]
Valentin, Jeremy [2 ]
Kallinikou, Zacharenia [2 ]
Toggweiler, Stefan [1 ]
Weissner, Melissa [3 ]
Muenzel, Thomas [3 ]
Cook, Stephane [2 ]
Gori, Tommaso [3 ]
机构
[1] Luzerner Kantonsspital, Dept Cardiol, Luzern, Switzerland
[2] Hosp & Univ Fribourg, Fribourg, Switzerland
[3] Univ Med Ctr Mainz & German Ctr Cardiovascular Re, Dept Med 2, Partner Site Rhine Main, Mainz, Germany
基金
瑞士国家科学基金会;
关键词
bioresorbable vascular scaffold; optical coherence tomography; percutaneous coronary intervention; peristrut low intensity area; scaffold thrombosis; stent thrombosis; INTRAVASCULAR ULTRASOUND FINDINGS; SIROLIMUS-ELUTING STENT; VIVO ACUTE STENT; CORONARY STENT; ABSORB EXTEND; COVERAGE; RECOIL;
D O I
10.1161/CIRCINTERVENTIONS.114.002518
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Everolimus-eluting bioresorbable vascular scaffolds have been developed to improve late outcomes after coronary interventions. However, recent registries raised concerns regarding an increased incidence of scaffold thrombosis (ScT). The mechanism of ScT remains unknown. Methods and Results-The present study investigated angiographic and optical coherence tomography findings in patients experiencing ScT. Fifteen ScT (14 patients, 79% male, age 59 +/- 10 years) occurred at a median of 16 days (25%-75% interquartile range: 1-263 days) after implantation. Early ScT (< 30 days) occurred in 8 cases (53%). Possible causal factors in these patients included insufficient platelet inhibition in 2 cases and procedural factors (scaffold underexpansion, undersizing, or geographical miss) in 4 cases. No obvious cause could be found in 2 early ScT. In late (>1 month) and very late (>1 year) ScT (respectively, 5 and 2 cases), 5 scaffolds showed intimal neovessels or marked peristrut low-intensity areas. Scaffold fractures were additionally found in 2 patients, and scaffold collapse was found in 1 patient with very late ScT. Extensive strut malapposition was the presumed cause for ScT in 1 case. One scaffold did not show any morphological abnormality. Thrombectomy specimens were analyzed in 3 patients and did not demonstrate increased numbers of inflammatory cells. Conclusions-The mechanisms of early ScT seem to be similar to metallic stents (mechanical and inadequate antiplatelet therapy). The predominant finding in late and very late ScT is peristrut low-intensity area.
引用
收藏
页数:9
相关论文
共 34 条
[1]   The ABSORB EXTEND study: preliminary report of the twelve-month clinical outcomes in the first 512 patients enrolled [J].
Abizaid, Alexandre ;
Ribamar Costa, J., Jr. ;
Bartorelli, Antonio L. ;
Whitbourn, Robert ;
van Geuns, Robert Jan ;
Chevalier, Bernard ;
Patel, Tejas ;
Seth, Ashok ;
Stuteville, Marrianne ;
Dorange, Cecile ;
Cheong, Wai-Fung ;
Sudhir, Krishnankutty ;
Serruys, Patrick W. .
EUROINTERVENTION, 2015, 10 (12) :1396-1401
[2]   Intravascular ultrasound findings during episodes of drug-eluting Stent thrombosis [J].
Alfonso, Fernando ;
Suarez, Alfonso ;
Perez-Vizcayno, Maria J. ;
Moreno, Raul ;
Escaned, Javier ;
Banuelos, Camino ;
Jimenez, Pilar ;
Bernardo, Esther ;
Angiolillo, Dominick J. ;
Hernandez, Rosana ;
Macaya, Carlos .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (21) :2095-2097
[3]  
[Anonymous], EUROINTERVENTION
[4]   Serial angioscopic evidence of incomplete neointimal coverage after sirolimus-eluting stent implantation [J].
Awata, Masaki ;
Kotani, Jun-ichi ;
Uematsu, Masaaki ;
Morozumi, Takakazu ;
Watanabe, Tetsuya ;
Onishi, Toshinari ;
Iida, Osamu ;
Sera, Fusako ;
Nanto, Shinsuke ;
Hori, Masatsugu ;
Nagata, Seiki .
CIRCULATION, 2007, 116 (08) :910-916
[5]   Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation [J].
Cook, Stephane ;
Wenaweser, Peter ;
Togni, Mario ;
Billinger, Michael ;
Morger, Cyrill ;
Seiler, Christian ;
Vogel, Rolf ;
Hess, Otto ;
Meier, Bernhard ;
Windecker, Stephan .
CIRCULATION, 2007, 115 (18) :2426-2434
[6]   Correlation of Intravascular Ultrasound Findings With Histopathological Analysis of Thrombus Aspirates in Patients With Very Late Drug-Eluting Stent Thrombosis [J].
Cook, Stephane ;
Ladich, Elena ;
Nakazawa, Gaku ;
Eshtehardi, Parham ;
Neidhart, Michel ;
Vogel, Rolf ;
Togni, Mario ;
Wenaweser, Peter ;
Billinger, Michael ;
Seiler, Christian ;
Gay, Steffen ;
Meier, Bernhard ;
Pichler, Werner J. ;
Jueni, Peter ;
Virmani, Renu ;
Windecker, Stephan .
CIRCULATION, 2009, 120 (05) :391-399
[7]   Early Stent Thrombosis Past, Present, and Future [J].
Cook, Stephane ;
Windecker, Stephan .
CIRCULATION, 2009, 119 (05) :657-659
[8]   Early change in invasive measures of microvascular function can predict myocardial recovery following PCI for ST-elevation myocardial infarction [J].
Cuculi, Florim ;
Dall'Armellina, Erica ;
Manlhiot, Cedric ;
De Caterina, Alberto R. ;
Colyer, Sharon ;
Ferreira, Vanessa ;
Morovat, Alireza ;
Prendergast, Bernard D. ;
Forfar, J. Colin ;
Alp, Nicholas J. ;
Choudhury, Robin P. ;
Neubauer, Stefan ;
Channon, Keith M. ;
Banning, Adrian P. ;
Kharbanda, Rajesh K. .
EUROPEAN HEART JOURNAL, 2014, 35 (29) :1971-1980
[9]   Relationship of plasma neuropeptide Y with angiographic, electrocardiographic and coronary physiology indices of reperfusion during ST elevation myocardial infarction [J].
Cuculi, Florim ;
Herring, Neil ;
De Caterina, Alberto R. ;
Banning, Adrian P. ;
Prendergast, Bernard D. ;
Forfar, John C. ;
Choudhury, Robin P. ;
Channon, Keith M. ;
Kharbanda, Rajesh K. .
HEART, 2013, 99 (16) :1198-1203
[10]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351