During 1988-1999 39 unstable fractures of the distal clavicle (Neer 2) were operated on in Oulu University Hospital. Kirschner wire (K-wire) fixation was used in 22 cases and a clavicular hook plate in 17. Shoulder symptoms and function were assessed using self-administered questionnaires devised by L'Insalata et al. (1997), and Constant scoring. Mean follow-up was 6.2 years in the K-wire fixation group and 2.0 years in the clavicular hook plate one. The mean L'Insalata scores were 91 in both groups (92% and 93% of the contralateral side) and the mean Constant scores 84 (95%) and 90 (96%) for K-wire fixation and the clavicular hook plate, respectively. Complications commonly occurred with K-wires, which migrated in 12 cases, resulting in loss of reduction in 7 and infection in 3, and 2 cases of non-union. In the clavicular hook plate group, there was 1 complication, a fracture of the clavicle, and 2 cases of non-union. We conclude that shoulder symptoms were reduced and function restored to an adequate level by both methods, but complications were unacceptably frequent when K-wires were used. The clavicular hook plate was better in this respect and it is therefore recommended.
引用
收藏
页码:50 / 53
页数:4
相关论文
共 22 条
  • [1] CORACOCLAVICULAR SCREW FIXATION FOR UNSTABLE FRACTURES OF THE DISTAL CLAVICLE - A REPORT OF 5 CASES
    BALLMER, FT
    GERBER, C
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02): : 291 - 294
  • [2] CONSTANT CR, 1987, CLIN ORTHOP RELAT R, P160
  • [3] Eberle C, 1992, Z Unfallchir Versicherungsmed, V85, P134
  • [4] FRACTURES OF THE DISTAL CLAVICLE - A CASE FOR FIXATION
    EDWARDS, DJ
    KAVANAGH, TG
    FLANNERY, MC
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1992, 23 (01): : 44 - 46
  • [5] ESKOLA A, 1987, ANN CHIR GYNAECOL FE, V76, P167
  • [6] Type 2 fractures of the distal clavicle: A new surgical technique
    Goldberg, JA
    Bruce, WM
    Sonnabend, DH
    Walsh, WR
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 1997, 6 (04) : 380 - 382
  • [7] Hackenbruch W, 1994, Z Unfallchir Versicherungsmed, V87, P145
  • [8] THE STABILIZING EFFECT OF VARIOUS IMPLANTS ON THE TORN ACROMIOCLAVICULAR JOINT - A BIOMECHANICAL STUDY
    KIEFER, H
    CLAES, L
    BURRI, C
    HOLZWARTH, J
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1986, 106 (01) : 42 - 46
  • [9] Kona J, 1990, J Orthop Trauma, V4, P115
  • [10] Migration of Kirschner wires following fixation of the clavicle - a report of 2 cases
    Leppilahti, J
    Jalovaara, P
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (05): : 517 - 519