Mitigation of Current Distortion in a Three-Phase Microinverter With Phase Skipping Using a Synchronous Sampling DC-Link Voltage Control

被引:15
作者
Tayebi, S. Milad [1 ]
Batarseh, Issa [1 ]
机构
[1] Univ Cent Florida, Dept Elect Engn & Comp Sci, Orlando, FL 32826 USA
关键词
DC bus; dc-link capacitor optimization; dc-link voltage control; film capacitors; minimizing dc-link capacitance; three-phase microinverters; INVERTERS; DESIGN; OPTIMIZATION; TOPOLOGIES; ENERGY; MODULE;
D O I
10.1109/TIE.2017.2760864
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
To improve light load efficiency, a three-phase photovoltaic (PV)-based microinverter may operate in single-phase, two-phase or three-phase mode depending on the available input power. Therefore, its dc-link capacitor may be subjected to large peak-to-peak voltage ripple when operating in phase skipping mode. This paper determines the minimum value of the dc-link capacitor by allowing the maximum acceptable voltage ripple on the dc link. This allows for the use of film capacitors instead of electrolytic capacitors in order to improve the microinverter reliability. Unfortunately, higher dc-link voltage ripple introduces harmonic distortion on the inverter output current waveform if it is not compensated for by the dc-link voltage controller. This paper proposes a simple synchronous control method to regulate the dc-link voltage with the presence of large voltage ripple. The dc-link voltage controller is synchronized with the phase-locked loop and samples the average value of dc-link voltage without introducing unwanted harmonics into the voltage sense path. Experimental results were obtained from a 300-W three-phase half-bridge microinverter prototype to verify the proposed dc-link voltage control performance. Inverter output current total harmonic distortion of 1.6% was achieved even though the dc-link peak-to-peak voltage ripple reached as high as 87 V with 219-V split dc-link voltage. Dynamic response is fast enough to easily track the most extreme ramp change in input PV power.
引用
收藏
页码:3910 / 3920
页数:11
相关论文
共 20 条
  • [1] [Anonymous], 2003, P IEEE POW TECH C BO
  • [2] Design and Analysis of a Higher Order Power Filter for Grid-Connected Renewable Energy Systems
    Anzalchi, Arash
    Moghaddami, Masood
    Moghadasi, Amir
    Pour, Maneli Malek
    Sarwat, Arif I.
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (05) : 4149 - 4161
  • [3] A New Topology of Higher Order Power Filter for Single-Phase Grid-Tied Voltage-Source Inverters
    Anzalchi, Arash
    Moghaddami, Masood
    Moghaddasi, Amir
    Sarwat, Arif I.
    Rathore, Akshay K.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (12) : 7511 - 7522
  • [4] Balog R, 2002, IEEE POWER ELECTRON, P591, DOI 10.1109/PSEC.2002.1022517
  • [5] Bower W., 2004, Performance test protocol for evaluating inverters used in grid-connected photovoltaic systems
  • [6] 20 years of life and more: Where is the end of life of a PV module?
    Dunlop, ED
    Halton, D
    Ossenbrink, HA
    [J]. CONFERENCE RECORD OF THE THIRTY-FIRST IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE - 2005, 2005, : 1593 - 1596
  • [7] Erickson R.W., 2001, FUNDAMENTALS POWER E, V2nd, P637
  • [8] Reliability of Candidate Photovoltaic Module-Integrated-Inverter (PV-MII) Topologies-A Usage Model Approach
    Harb, Souhib
    Balog, Robert S.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (06) : 3019 - 3027
  • [9] A Systematic Approach to DC-Bus Control Design in Single-Phase Grid-Connected Renewable Converters
    Karimi-Ghartemani, Masoud
    Khajehoddin, Sayed Ali
    Jain, Praveen
    Bakhshai, Alireza
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (07) : 3158 - 3166
  • [10] DC-Bus Design and Control for a Single-Phase Grid-Connected Renewable Converter With a Small Energy Storage Component
    Khajehoddin, Sayed Ali
    Karimi-Ghartemani, Masoud
    Jain, Praveen K.
    Bakhshai, Alireza
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (07) : 3245 - 3254