Total respiratory impedance measured by means of the forced oscillation technique in subjects with and without respiratory complaints

被引:56
作者
Pasker, HG [1 ]
Schepers, R [1 ]
Clement, J [1 ]
VandeWoestijne, KP [1 ]
机构
[1] UZ GASTHUISBERG, LAB PNEUMOL, B-3000 LOUVAIN, BELGIUM
关键词
forced oscillation; respiratory complaints; respiratory impedance; respiratory reactance; respiratory resistance;
D O I
10.1183/09031936.96.09010132
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The purpose of this study was to determine whether the forced oscillation technique is more sensitive than spirometry to detect lung Function alterations in subjects with respiratory complaints, The input impedance of the respiratory system (between 2 and 24 Hz) and maximal expiratory flows and volumes were measured in 1,255 subjects referred for routine spirometry, A questionnaire concerning respiratory complaints was administered, A discriminant analysis was performed between subgroups of subjects without (137 males and 140 females), with moderate (115 males and 109 females) and with marked respiratory complaints (149 males and 132 females), A clear-cut separation was achieved by this analysis only between those subjects without and with marked complaints, Both lung volumes and flows as well as impedance parameters (mean value and frequency dependence of resistance in females, mean resistance in males) contributed to the discrimination of subjects without and with marked respiratory complaints, although there was only a moderate decrease of discriminative power when the impedance parameters were excluded. The contribution of the forced oscillation parameters to discriminative power was larger in females than in males (40 vs 19%), which may be related to the higher prevalence of asthma in our population of females, Excluding the subjects with marked functional impairment improved the share of forced oscillation parameters only slightly with respect to lung volumes and flows (females 54 vs males 23%), Considered separately, however, the sensitivity of spirometry and forced oscillation technique to detect symptomatic people appeared to be similar, We conclude that impedance measurements by forced oscillation technique and routine spirometry are both associated with respiratory complaints, Our results indicate that the information provided by impedance measurements can be complimentary to that obtained by spirometric indices.
引用
收藏
页码:131 / 139
页数:9
相关论文
共 26 条
[1]  
[Anonymous], 1987, Am Rev Respir Dis, V136, P1285
[2]  
BROCHARD L, 1987, AM REV RESPIR DIS, V135, P579
[3]   EFFECT OF UPPER AIRWAY SHUNT AND SERIES PROPERTIES ON RESPIRATORY IMPEDANCE MEASUREMENTS [J].
CAUBERGHS, M ;
VANDEWOESTIJNE, KP .
JOURNAL OF APPLIED PHYSIOLOGY, 1989, 66 (05) :2274-2279
[4]   TOTAL RESISTANCE AND REACTANCE IN PATIENTS WITH RESPIRATORY COMPLAINTS WITH AND WITHOUT AIRWAYS OBSTRUCTION [J].
CLEMENT, J ;
LANDSER, FJ ;
VANDEWOESTIJNE, KP .
CHEST, 1983, 83 (02) :215-220
[5]   OSCILLATION MECHANICS OF LUNGS AND CHEST IN MAN [J].
DUBOIS, AB ;
BRODY, AW ;
LEWIS, DH ;
BURGESS, BF .
JOURNAL OF APPLIED PHYSIOLOGY, 1956, 8 (06) :587-594
[6]   FORCED OSCILLATION TECHNIQUE - COMPARISON OF 2 DEVICES [J].
FRANKEN, H ;
CAUBERGHS, M ;
RINGELHANN, A ;
CLEMENT, J ;
VANDEWOESTIJNE, KP .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 59 (05) :1654-1659
[7]  
GIBSON GJ, 1993, EUR RESPIR J, V6, P155
[8]  
GOVAERTS E, 1993, EUR RESPIR J, V6, P1181
[9]  
HAYES DA, 1979, AM REV RESPIR DIS, V120, P1095
[10]  
JORNA THJ, 1994, EUR RESPIR REV, V4, P155