Experimental analysis of R22 and R407c flow through electronic expansion valve

被引:34
作者
Zhang, C [1 ]
Ma, SW [1 ]
Chen, JP [1 ]
Chen, ZJ [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200030, Peoples R China
关键词
electronic expansion valve; refrigerant; correlation; mass flow rate;
D O I
10.1016/j.enconman.2005.05.005
中图分类号
O414.1 [热力学];
学科分类号
摘要
The objective of this study is to present test results and to develop a dimensionless correlation on the basis of experimental data to predict the mass flow rate of R22 and its alternative refrigerant R407c through an electronic expansion valve (EEV). The mass flow rate was measured at a series of condensing temperatures, evaporating temperatures and degrees of subcooling at the EEV inlet with five opening setting degrees of the EEV. The experimental results were analyzed, and it was found that the operation condition, flow area and the thermophysical properties of the refrigerant would affect the mass flow rate through the EEV. A new correlation based on the Buckingham pi theorem was developed to predict the mass flow rate of refrigerants through the EEV. The relative deviations of the predicted value by using this correlation are from -10.74% to 9.26% for R22 and from -14.20% to 22.10% for R407c. The average deviations and standard deviations are -0.79% and 5.02% for R22 and 0.67% and 8.08% for R407c, respectively. The relative deviation was analyzed in terms of the operation condition and flow area of the EEV. This correlation can be used to predict the mass flow rate through EEVs whose largest flow area is less than 2.544 mm(2) (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:529 / 544
页数:16
相关论文
共 16 条
  • [1] AARON AA, 1990, ASHRAE T, V96, P729
  • [2] [Anonymous], ASHRAE T
  • [3] BOLSTAD MM, 1948, REFRIGERATING ENG, V56, P519
  • [4] On physically similar systems, illustrations of the use of dimensional equations
    Buckingham, E
    [J]. PHYSICAL REVIEW, 1914, 4 (04): : 345 - 376
  • [5] CHEN ZH, 1990, ASHRAE TRAN, V96, P550
  • [6] A generalized correlation for two-phase flow of alternative refrigerants through short tube orifices
    Choi, J
    Chung, J
    Kim, Y
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (04): : 393 - 400
  • [7] Cooper L., 1957, REF ENG, V65, P37
  • [8] Davies A., 1973, ASHRAE T, V79, P112
  • [9] Designing towards emotional usability in customer interfaces - trustworthiness of cyber-banking system interfaces
    Kim, J
    Moon, JY
    [J]. INTERACTING WITH COMPUTERS, 1998, 10 (01) : 1 - 29
  • [10] Experimental investigation of the performance of R22, R407C and R410A in several capillary tubes for air-conditioners
    Kim, SG
    Kim, MS
    Ro, ST
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2002, 25 (05): : 521 - 531