Low-Dose Computed Tomography Reduces Radiation Exposure by 90% Compared With Traditional Computed Tomography Among Patients Undergoing Hip-Preservation Surgery

被引:44
作者
Su, Alvin W. [1 ]
Hillen, Travis J. [2 ]
Eutsler, Eric P. [2 ]
Bedi, Asheesh [3 ]
Ross, James R. [4 ]
Larson, Christopher M. [5 ]
Clohisy, John C. [1 ]
Nepple, Jeffrey J. [1 ]
机构
[1] Washington Univ, Dept Orthopaed Surg, St Louis, MO USA
[2] Washington Univ, Mallinckrodt Inst Radiol, St Louis, MO USA
[3] Univ Michigan, Dept Orthoped Surg, MedSport, Ann Arbor, MI 48109 USA
[4] Florida Atlantic Univ, Coll Med, BocaCare Orthoped, Boca Raton, FL 33431 USA
[5] Twin City Orthoped, Minnesota Orthoped Sports Med Inst, Edina, MN USA
关键词
CT CORONARY-ANGIOGRAPHY; CANCER-MORTALITY; O-ARM; RADIOGRAPHY; MORPHOLOGY; DISEASE; RISK;
D O I
10.1016/j.arthro.2018.11.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To compare the delivered radiation dose between a low-dose hip computed tomography (CT) scan protocol and traditional hip CT scan protocols (i.e., "traditional CT"). Methods: This was a retrospective comparative cohort study. Patients who underwent hip-preservation surgery (including arthroscopy, surgical hip dislocation, or periacetabular osteotomy procedures) at our institution between 2016 and 2017 were identified. Patients were excluded if they had a body mass index (BMI) greater than 35, they underwent previous surgery, or a radiation dose report was absent. The low-dose group included patients who underwent hip CT at our institution using a standardized protocol of 100 kV (peak), 100 milliampere-seconds (mAs), and a limited scanning field. The traditional CT group included patients who had hip CT scans performed at outside institutions. The total effective dose (E-hip), effective dose per millimeter of body length scanned, patients' age, and patients' BMI were compared by univariate analysis. The correlation of E-hip to BMI was assessed. Results: The study included 41 consecutive patients in the low-dose group and 18 consecutive patients in the traditional CT group. Low-dose CT resulted in a 90% reduction in radiation exposure compared with traditional CT (E-hip, 0.97 +/- 0.28 mSv vs 9.68 +/- 6.67 mSv; P < .0001). Age (28 +/- 11 years vs 26 +/- 10 years, P = .42), sex (83% female patients vs 76% female patients, P = .74), and BMI (24 +/- 3 vs 24 +/- 3, P = .75) were not different between the 2 groups. E-hip had a poor but significant correlation to BMI in the low-dose CT group (R-2 = 0.14, slope = 0.03, P = .02) and did not correlate to BMI in the traditional CT group (R-2 = 0.13, P = .14). Conclusions: A low-dose hip CT protocol for the purpose of hip-preservation surgical planning resulted in a 90% reduction in radiation exposure compared with traditional CT. Level of Evidence: Level II, diagnostic study.
引用
收藏
页码:1385 / 1392
页数:8
相关论文
共 41 条
[41]   Low-dose chest CT: Optimizing radiation protection for patients [J].
Zhu, XH ;
Yu, JQ ;
Huang, Z .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (03) :809-816