Low-Dose Computed Tomography Reduces Radiation Exposure by 90% Compared With Traditional Computed Tomography Among Patients Undergoing Hip-Preservation Surgery

被引:44
作者
Su, Alvin W. [1 ]
Hillen, Travis J. [2 ]
Eutsler, Eric P. [2 ]
Bedi, Asheesh [3 ]
Ross, James R. [4 ]
Larson, Christopher M. [5 ]
Clohisy, John C. [1 ]
Nepple, Jeffrey J. [1 ]
机构
[1] Washington Univ, Dept Orthopaed Surg, St Louis, MO USA
[2] Washington Univ, Mallinckrodt Inst Radiol, St Louis, MO USA
[3] Univ Michigan, Dept Orthoped Surg, MedSport, Ann Arbor, MI 48109 USA
[4] Florida Atlantic Univ, Coll Med, BocaCare Orthoped, Boca Raton, FL 33431 USA
[5] Twin City Orthoped, Minnesota Orthoped Sports Med Inst, Edina, MN USA
关键词
CT CORONARY-ANGIOGRAPHY; CANCER-MORTALITY; O-ARM; RADIOGRAPHY; MORPHOLOGY; DISEASE; RISK;
D O I
10.1016/j.arthro.2018.11.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To compare the delivered radiation dose between a low-dose hip computed tomography (CT) scan protocol and traditional hip CT scan protocols (i.e., "traditional CT"). Methods: This was a retrospective comparative cohort study. Patients who underwent hip-preservation surgery (including arthroscopy, surgical hip dislocation, or periacetabular osteotomy procedures) at our institution between 2016 and 2017 were identified. Patients were excluded if they had a body mass index (BMI) greater than 35, they underwent previous surgery, or a radiation dose report was absent. The low-dose group included patients who underwent hip CT at our institution using a standardized protocol of 100 kV (peak), 100 milliampere-seconds (mAs), and a limited scanning field. The traditional CT group included patients who had hip CT scans performed at outside institutions. The total effective dose (E-hip), effective dose per millimeter of body length scanned, patients' age, and patients' BMI were compared by univariate analysis. The correlation of E-hip to BMI was assessed. Results: The study included 41 consecutive patients in the low-dose group and 18 consecutive patients in the traditional CT group. Low-dose CT resulted in a 90% reduction in radiation exposure compared with traditional CT (E-hip, 0.97 +/- 0.28 mSv vs 9.68 +/- 6.67 mSv; P < .0001). Age (28 +/- 11 years vs 26 +/- 10 years, P = .42), sex (83% female patients vs 76% female patients, P = .74), and BMI (24 +/- 3 vs 24 +/- 3, P = .75) were not different between the 2 groups. E-hip had a poor but significant correlation to BMI in the low-dose CT group (R-2 = 0.14, slope = 0.03, P = .02) and did not correlate to BMI in the traditional CT group (R-2 = 0.13, P = .14). Conclusions: A low-dose hip CT protocol for the purpose of hip-preservation surgical planning resulted in a 90% reduction in radiation exposure compared with traditional CT. Level of Evidence: Level II, diagnostic study.
引用
收藏
页码:1385 / 1392
页数:8
相关论文
共 41 条
[1]   Why Do Hip Arthroscopy Procedures Fail? [J].
Bogunovic, Ljiljana ;
Gottlieb, Meghan ;
Pashos, Gail ;
Baca, Geneva ;
Clohisy, John C. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (08) :2523-2529
[2]  
Bottollier-Depois JF, 2000, RADIAT RES, V153, P526, DOI 10.1667/0033-7587(2000)153[0526:AETCRD]2.0.CO
[3]  
2
[4]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[5]   Cumulative Radiation Exposure to Patients Undergoing Arthroscopic Hip Preservation Surgery and Occupational Radiation Exposure to the Surgical Team [J].
Canham, Colin D. ;
Williams, Richard B. ;
Schiffman, Scott ;
Weinberg, Eric P. ;
Giordano, Brian D. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2015, 31 (07) :1261-1268
[6]   Persistent Structural Disease Is the Most Common Cause of Repeat Hip Preservation Surgery [J].
Clohisy, John C. ;
Nepple, Jeffrey J. ;
Larson, Christopher M. ;
Zaltz, Ira ;
Millis, Michael .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (12) :3788-3794
[7]   Radiographic Evaluation of the Hip has Limited Reliability [J].
Clohisy, John C. ;
Carlisle, John C. ;
Trousdale, Robert ;
Kim, Young-Jo ;
Beaule, Paul E. ;
Morgan, Patrick ;
Steger-May, Karen ;
Schoenecker, Perry L. ;
Millis, Michael .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (03) :666-675
[8]   Contemporary Concepts in the Young Adult Hip Patient: Periacetabular Osteotomy for Hip Dysplasia [J].
Coobs, Benjamin R. ;
Xiong, Ao ;
Clohisy, John C. .
JOURNAL OF ARTHROPLASTY, 2015, 30 (07) :1105-1108
[9]   Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007 [J].
de Gonzalez, Amy Berrington ;
Mahesh, Mahadevappa ;
Kim, Kwang-Pyo ;
Bhargavan, Mythreyi ;
Lewis, Rebecca ;
Mettler, Fred ;
Land, Charles .
ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) :2071-2077
[10]   Low-dose abdominal computed tomography for detection of urinary stone disease - Impact of additional spectral shaping of the X-ray beam on image quality and dose parameters [J].
Dewes, Patricia ;
Frellesen, Claudia ;
Scholtz, Jan-Erik ;
Fischer, Sebastian ;
Vogl, Thomas J. ;
Bauer, Ralf W. ;
Schulz, Boris .
EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (06) :1058-1062