Application of modified Kitagawa-Takahashi diagram for fatigue strength assessment of cast Al-Si-Cu alloys

被引:40
|
作者
Garb, Christian [1 ]
Leitner, Martin [1 ]
Stauder, Bernhard [2 ]
Schnubel, Dirk [3 ]
Gruen, Florian [1 ]
机构
[1] Univ Leoben, Dept Prod Engn, Chair Mech Engn, Franz Josef Str 18, A-8700 Leoben, Austria
[2] Nemak Linz Gmbh, Zeppelinstr 24, A-4030 Linz, Austria
[3] Nemak Dillingen GmbH, Marie Curie Str, D-66763 Dillingen, Saar, Germany
关键词
Fatigue strength; Micropore size; Fractographic analyses; Kitagawa-Takahashi diagram; CRACK-GROWTH; CLOSURE MECHANISMS; ALUMINUM ALLOY; THRESHOLD; BEHAVIOR; A356-T6; COMPRESSION; PROPAGATION; STRESS; MICROSTRUCTURE;
D O I
10.1016/j.ijfatigue.2018.01.030
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper presents comprehensive fatigue test results utilizing small-scale specimens extracted from AlSi8Cu3 and AlSi7Cu0.5Mg aluminium-cast crankcases and cylinder heads. The experimental results act as basis to set-up a defect size-based material model applying the Kitagawa-Takahashi approach and the modification by El-Haddad and Chapetti. The round samples were manufactured from three different component locations to achieve a variation in microstructure and micropore sizes. Fractographical analyses were executed to examine the size and shape of the crack-initiating micropores. Mostly shrinkage pores were detected within the investigated alloy specifications, except the Na-modified alloy, where a significant occurrence of gas pores was observed. Elaborated crack propagation tests were performed to determine the long crack threshold Delta K-eff,K-th and analyse the short crack region. Kitagawa-Takahashi, El-Haddad and Chapetti models were worked out combining fatigue strength, fractographical as well as fracture mechanics characteristics. The Kitagawa-Takahashi and El-Haddad approach mostly revealed non-conservative results over all data sets including several alloy specifications. The application of the Chapetti model, which additionally considers short crack growth, led to an improvement of the practicability of the defect-based model compared to the fatigue test results. Finally it is shown that the Chapetti approach was well appropriate to set-up a generalized, local microstructure-dependent fatigue assessment, especially for the investigated AlSi7Cu0.5Mg cylinder head samples. It can be concluded that the main influence on the fatigue strength was the micropore size, as well as the heat treatment and eutectic modifier, whereas the micropore shape seemed to have less significance. Hence, an application of defect-based models, such as the Kitagawa-Takahashi, El-Haddad and Chapetti approach using simplified pore size parameters such as an equivalent diameter, enables a proper local fatigue assessment of light weight cast aluminium components.
引用
收藏
页码:256 / 268
页数:13
相关论文
共 50 条
  • [1] A probabilistic Kitagawa-Takahashi diagram for fatigue strength assessment of cast aluminium alloys
    Aigner, R.
    Pusterhofer, S.
    Pomberger, S.
    Leitner, M.
    Stoschka, M.
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2019, 745 : 326 - 334
  • [2] Simulation of the Kitagawa-Takahashi diagram using a probabilistic approach for cast Al-Si alloys under different multiaxial loads
    Viet-Duc Le
    Morel, Franck
    Bellett, Daniel
    Saintier, Nicolas
    Osmond, Pierre
    INTERNATIONAL JOURNAL OF FATIGUE, 2016, 93 : 109 - 121
  • [3] Analysis of pit to crack transition under corrosion fatigue & the safe-life approach using the modified Kitagawa-Takahashi diagram
    Sadananda, K.
    Vasudevan, A. K.
    INTERNATIONAL JOURNAL OF FATIGUE, 2020, 134
  • [4] Modification of a Defect-Based Fatigue Assessment Model for Al-Si-Cu Cast Alloys
    Aigner, Roman
    Leitner, Martin
    Stoschka, Michael
    Hannesschlaeger, Christian
    Wabro, Thomas
    Ehart, Robert
    MATERIALS, 2018, 11 (12)
  • [5] Effect of carbon nanotubes on the mechanical properties of cast Al-Si-Cu alloys
    Okayasu, Mitsuhiro
    Wu, Shauha
    Hasanah, Indah Uswatun
    MATERIALS SCIENCE AND TECHNOLOGY, 2022, 38 (04) : 237 - 245
  • [6] The fatigue damage development in a cast Al-Si-Cu alloy
    Dietrich, Lech
    Radziejewska, Joanna
    MATERIALS & DESIGN, 2011, 32 (01) : 322 - 329
  • [7] Optimisation of solution treatment of cast Al-Si-Cu alloys
    Sjolander, E.
    Seifeddine, S.
    MATERIALS & DESIGN, 2010, 31 : S44 - S49
  • [8] Assessment of the Effect of Mg Addition on the Solidification Behavior of Al-Si-Cu Cast Alloys
    Mohamed, A. M. A.
    Samuel, F. H.
    Alkahtani, S.
    TRANSACTIONS OF THE AMERICAN FOUNDRY SOCIETY, VOL 120, 2012, 120 : 85 - 96
  • [9] Defect-correlated fatigue assessment of A356-T6 aluminum cast alloy using computed tomography based Kitagawa-Takahashi diagrams
    Tenkamp, Jochen
    Koch, Alexander
    Knorre, Stephan
    Krupp, Ulrich
    Michels, Wilhelm
    Walther, Frank
    INTERNATIONAL JOURNAL OF FATIGUE, 2018, 108 : 25 - 34
  • [10] Microstructure evolution of cast Al-Si-Cu alloys in solution treatment
    Dingfei Zhang
    Jian Peng
    Guangjie Huang
    Dingding Zeng
    Journal of Wuhan University of Technology-Mater. Sci. Ed., 2008, 23