A water-soluble fluorescent probe for detecting creatinine in totally aqueous media and imaging exogenous creatinine in living cells

被引:10
作者
Du, Fangkai [1 ]
Li, Mengru [1 ]
Wei, Yanye [1 ]
Huang, Donglian [1 ]
Zhou, Yan [1 ]
Yang, Lifang [1 ]
Chen, Jian [2 ]
Liu, Shaogang [1 ]
Tan, Xuecai [1 ]
机构
[1] Guangxi Univ Nationalitics, Key Lab Guangxi Coll & Univ Food Safety & Pharmac, Guangxi Key Lab Chem & Engn Forest Prod, Sch Chem & Chem Engn, Nanning 530008, Peoples R China
[2] Hunan Univ Sci & Technol, Hunan Prov Key Lab Controllable Preparat & Funct, Key Lab Theoret Organ Chem & Funct Mol,Inst Funct, Hunan Prov Coll Key Lab QSAR QSPR,Minist Educ, Xiangtan 411201, Hunan, Peoples R China
关键词
Fluorescent probe; Creatinine; Blood; Living cells; Imaging; QUANTITATIVE-DETERMINATION; LIQUID-CHROMATOGRAPHY; SELECTIVE DETECTION; BIOMARKERS; SAMPLES; SENSOR; IONS;
D O I
10.1007/s00216-019-01695-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The design of vigorous tools for creatinine determination is extremely important in the diagnosis and treatment of kidney diseases. In the study, we examine a robust fluorescent turn-on probe (NCP-Pd) for creatinine detection in a completely aqueous solution based on the metal palladium-catalyzed reaction. In the presence of creatinine, the NCP-Pd dissociates and subsequently restores the fluorescence due to elimination of the heavy atom quenching effect and prevention of the photoinduced electron transfer effect. The probe NCP-Pd displays excellent detecting performance with respect to creatinine such as good water solubility, high selectivity, and a low detection limit (0.16M). Additionally, in order to ensure its clinical application, this probe is operated in blood serum samples for detecting creatinine and compared with a commercial clinical method. The results indicate an extremely high agreement with the commercial clinical method. Furthermore, the results confirm that the probe NCP-Pd exhibits satisfactory cell permeability and low cytotoxicity and can detect creatinine in L929 and HCT116 cells. The study provides a potential application for detecting creatinine and conducting pathological research on creatinine-involved diseases.
引用
收藏
页码:2545 / 2553
页数:9
相关论文
共 41 条
[1]   Cyclam-functionalized carbon dots sensor for sensitive and selective detection of copper(II) ion and sulfide anion in aqueous media and its imaging in live cells [J].
Chen, Jian ;
Li, Ya ;
Lv, Kun ;
Zhong, Weibang ;
Wang, Hong ;
Wu, Zhan ;
Yi, Pinggui ;
Jiang, Jianhui .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 224 :298-306
[2]   Amphiphilic BODIPY-Based Photoswitchable Fluorescent Polymeric Nanoparticles for Rewritable Patterning and Dual-Color Cell Imaging [J].
Chen, Jian ;
Zhong, Weibang ;
Tang, Ying ;
Wu, Zhan ;
Li, Ya ;
Yi, Pinggui ;
Jiang, Jianhui .
MACROMOLECULES, 2015, 48 (11) :3500-3508
[3]   Probing Cellular Molecules with PolyA-Based Engineered Aptamer Nanobeacon [J].
Chen, Lizhen ;
Chao, Jie ;
Qu, Xiangmeng ;
Zhang, Hongbo ;
Zhu, Dan ;
Su, Shao ;
Aldalbahi, Ali ;
Wang, Lianhui ;
Pei, Hao .
ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (09) :8014-8020
[4]   Recent progress in the development of fluorescent, luminescent and colorimetric probes for detection of reactive oxygen and nitrogen species [J].
Chen, Xiaoqiang ;
Wang, Fang ;
Hyun, Ji Young ;
Wei, Tingwen ;
Qiang, Jian ;
Ren, Xintong ;
Shin, Injae ;
Yoon, Juyoung .
CHEMICAL SOCIETY REVIEWS, 2016, 45 (10) :2976-3016
[5]   Creatinine determination according to Jaffe-what does it stand for? [J].
Delanghe, Joris R. ;
Speeckaert, Marijn M. .
CLINICAL KIDNEY JOURNAL, 2011, 4 (01) :83-86
[6]   Ultrasensitive Fluorescent Biosensor for Creatinine Determination in Human Biofluids Based on Water Soluble Rhodamine B Dye-Au3+ ions Conjugate [J].
Ellairaja, S. ;
Shenbagavalli, K. ;
Vasantha, V. S. .
CHEMISTRYSELECT, 2017, 2 (03) :1025-1031
[7]   Special Issue of "DNA Nanotechnology" [J].
Fan, Chunai ;
Pei, Hao .
CHINESE JOURNAL OF CHEMISTRY, 2016, 34 (03) :251-251
[8]   Quantitative determination of taurine and related biomarkers in urine by liquid chromatography-tandem mass spectrometry [J].
Gamagedara, Sanjeewa ;
Shi, Honglan ;
Ma, Yinfa .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (02) :763-770
[9]   A highly selective and sensitive fluorescent chemosensor for Hg2+ in neutral buffer aqueous solution [J].
Guo, XF ;
Qian, XH ;
Jia, LH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (08) :2272-2273
[10]   Ratiometric detection and imaging of endogenous hypochlorite in live cells and in vivo achieved by using an aggregation induced emission (AIE)-based nanoprobe [J].
Huang, Yong ;
Zhang, Peisheng ;
Gao, Meng ;
Zeng, Fang ;
Qin, Anjun ;
Wu, Shuizhu ;
Tang, Ben Zhong .
CHEMICAL COMMUNICATIONS, 2016, 52 (45) :7288-7291