Biosensors in food processing

被引:183
作者
Thakur, M. S. [1 ]
Ragavan, K. V. [1 ]
机构
[1] CSIR Cent Food Technol Res Inst, Fermentat Technol & Bioengn Dept, Mysore 570020, Karnataka, India
来源
JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE | 2013年 / 50卷 / 04期
关键词
Biosensors; Food processing; CFTRI; Nanosensor; Aptamer; Immunosensor; Food safety; AMPEROMETRIC BIOSENSOR; ENZYME ELECTRODE; FISH FRESHNESS; ACRYLAMIDE; HYPOXANTHINE; RECOMMENDATIONS; IMMUNOSENSORS; SUBSTRATE; BENZENE; SYSTEMS;
D O I
10.1007/s13197-012-0783-z
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Optical based sensing systems that measure luminescence, fluorescence, reflectance and absorbance, etc., are some of the areas of applications of optical immunosensors. Immunological methods rely on specific binding of an antibody (monoclonal, polyclonal or engineered) to an antigen. Detection of specific microorganisms and microbial toxins requires immobilization of specific antibodies onto a given transducer that can produce signal upon attachment of typical microbe/microbial toxins. Inherent features of immunosensors such as specificity, sensitivity, speed, ease and on-site analysis can be made use for various applications. Safety of food and environment has been a major concern of food technologists and health scientists in recent years. There exists a strong need for rapid and sensitive detection of different components of foods and beverages along with the food borne and water borne pathogens, toxins and pesticide residues with high specificity. Biosensors present attractive, efficient alternative techniques by providing quick and reliable performances. There is a very good potential for application of biosensors for monitoring food quality and safety in food and bioprocessing industries in India.
引用
收藏
页码:625 / 641
页数:17
相关论文
共 78 条
[1]  
Akshath US, 2012, BIOSENS BIOELECTRON, DOI [10.1016/j.bios.2012.05.003, DOI 10.1016/J.BI0S.2012.05.003]
[2]  
[Anonymous], 2011, GLOB IND AN INC 2011
[3]  
[Anonymous], 2012, CHEM MEAT COOKED HIG
[4]  
Ansell RJ, 1996, CLIN CHEM, V42, P1506
[5]   Development of a biosensor for caffeine [J].
Babu, V. R. Sarath ;
Patra, S. ;
Karanth, N. G. ;
Kumar, M. A. ;
Thakur, M. S. .
ANALYTICA CHIMICA ACTA, 2007, 582 (02) :329-334
[6]  
Belitz H.-D., 2009, Food Chemistry, V4th, DOI [10.1007/978-3-540-69934-7, DOI 10.1007/978-3-540-69934-7]
[7]   Surface IR immunosensors for label-free detection of benzo[a]pyrene [J].
Boujday, Souhir ;
Nasri, Soumaya ;
Salmain, Michele ;
Pradier, Claire-Marie .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (04) :1750-1754
[8]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[9]   BIO-SENSORS BASED ON ION-SELECTIVE ELECTRODES [J].
CAMMANN, K .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1977, 287 (01) :1-9
[10]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671