Coronary computed tomography angiography using ultra-low-dose contrast media: radiation dose and image quality

被引:34
作者
Komatsu, Sei [1 ]
Kamata, Teruaki [2 ]
Imai, Atsuko [1 ,3 ]
Ohara, Tomoki [1 ]
Takewa, Mitsuhiko [1 ]
Ohe, Ryoko [1 ]
Miyaji, Kazuaki [2 ]
Yoshida, Junichi [1 ]
Kodama, Kazuhisa [1 ]
机构
[1] Amagasaki Cent Hosp, Ctr Cardiovasc, Amagasaki, Hyogo 6610976, Japan
[2] Amagasaki Cent Hosp, Dept Diagnost Imaging, Amagasaki, Hyogo 6610976, Japan
[3] Osaka Univ, Sch Med, Dept Cardiol, Osaka, Japan
关键词
Coronary computed tomography angiography; Contrast media; Tube potential; CT; PHANTOM; SINGLE;
D O I
10.1007/s10554-013-0201-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To analyze the invasiveness and image quality of coronary CT angiography (CCTA) with 80 kV. We enrolled 181 patients with low body weight and low calcium level. Of these, 154 patients were randomly assigned to 1 of 3 groups: 280 HU/80 kV (n = 51); 350 HU/80 kV (n = 51); or 350 HU/120 kV (n = 52). The amount of contrast media (CM) was decided with a CT number-controlling system. Twenty-seven patients were excluded because of an invalid time density curve by timing bolus. The predicted amount of CM, volume CT dose index, dose-length product, effective dose, image noise, and 5-point image quality were measured. The amounts of CM for the 80 kV/280 HU, 80 kV/350 HU, and 120 kV/350 HU groups were 10 +/- A 4 mL, 15 +/- A 7 mL, and 30 +/- A 6 mL, respectively. Although image noise was greater at 80 than 120 kV, there was no significant difference in image quality between 80 kV/350 HU and 120 kV/350 HU (p = 0.390). There was no significant difference in image quality between 80 kV/280 HU and 80 kV/350 HU (4.4 +/- A 0.7 vs. 4.7 +/- A 0.4, p = 0.056). The amount of CM and effective dose was lower for 80 kV CCTA than for 120 kV CCTA. CCTA at 80 kV/280 HU may decrease the amount of CM and radiation dose necessary while maintaining image quality.
引用
收藏
页码:1335 / 1340
页数:6
相关论文
共 50 条
  • [31] Radiomics in the evaluation of lung nodules: Intrapatient concordance between full-dose and ultra-low-dose chest computed tomography
    Autrusseau, Pierre-Alexis
    Labani, Aissam
    De Marini, Pierre
    Leyendecker, Pierre
    Hintzpeter, Cedric
    Ortlieb, Anne-Claire
    Calhoun, Michael
    Goldberg, Ilya
    Roy, Catherine
    Ohana, Mickael
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2021, 102 (04) : 233 - 239
  • [32] Ultra-low dose chest computed tomography: Effect of iterative reconstruction levels on image quality
    Afadzi, Mercy
    Lysvik, Elisabeth Kirkeby
    Andersen, Hilde Kjernlie
    Martinsen, Anne Catrine T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 114 : 62 - 68
  • [33] Automated Low-Kilovoltage Selection in Pediatric Computed Tomography Angiography Phantom Study Evaluating Effects on Radiation Dose and Image Quality
    Siegel, Marilyn Joy
    Ramirez-Giraldo, Juan Carlos
    Hildebolt, Charles
    Bradley, David
    Schmidt, Bernhard
    INVESTIGATIVE RADIOLOGY, 2013, 48 (08) : 584 - 589
  • [34] Improving the image quality of pediatric chest CT angiography with low radiation dose and contrast volume using deep learning image reconstruction
    Sun, Jihang
    Li, Haoyan
    Li, Jianying
    Yu, Tong
    Li, Michelle
    Zhou, Zuofu
    Peng, Yun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (07) : 3051 - 3058
  • [35] Comparison of radiation dose and its correlates between coronary computed tomography angiography and invasive coronary angiography in Northeastern Thailand
    Aupongkaroon, Phatraporn
    Makarawate, Pattarapong
    Chaosuwannakit, Narumol
    EGYPTIAN HEART JOURNAL, 2022, 74 (01)
  • [36] Low-dose computed tomography perceptual image quality assessment
    Lee, Wonkyeong
    Wagner, Fabian
    Galdran, Adrian
    Shi, Yongyi
    Xia, Wenjun
    Wang, Ge
    Mou, Xuanqin
    Ahamed, Md. Atik
    Imran, Abdullah Al Zubaer
    Oh, Ji Eun
    Kim, Kyungsang
    Baek, Jong Tak
    Lee, Dongheon
    Hong, Boohwi
    Tempelman, Philip
    Lyu, Donghang
    Kuiper, Adrian
    van Blokland, Lars
    Calisto, Maria Baldeon
    Hsieh, Scott
    Han, Minah
    Baek, Jongduk
    Maier, Andreas
    Wang, Adam
    Gold, Garry Evan
    Choi, Jang-Hwan
    MEDICAL IMAGE ANALYSIS, 2025, 99
  • [37] High-pitch prospective ECG-triggered helical coronary computed tomography angiography in clinical practice: image quality and radiation dose
    Kjell Bogaard
    Friso M. van der Zant
    Remco J. J. Knol
    Sjoerd Reinders
    Marije M. G. Krul
    Albert C. van Rossum
    Paul Knaapen
    Jan H. Cornel
    The International Journal of Cardiovascular Imaging, 2015, 31 : 125 - 133
  • [38] Low Dose versus Standard Single Heartbeat Acquisition Coronary Computed Tomography Angiography
    Di Cesare, Ernesto
    Di Sibio, Alessandra
    Gennarelli, Antonio
    Di Luzio, Margherita
    Casazza, Ines
    Splendiani, Alessandra
    Di Cesare, Annamaria
    Gravina, Giovanni Luca
    Barile, Antonio
    Masciocchi, Carlo
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2018, 8
  • [39] Peristaltic Contrast Media Injection Improved Image Quality and Decreased Radiation and Contrast Dose When Compared With Direct Drive Injection During Liver Computed Tomography
    Saade, Charbel
    Karout, Lina
    Khalife, Sarah
    Mayat, Ahmad
    Pillay, Sugendran
    Chan, Edward
    Maroun, Gilbert
    Alam, Raquelle
    Abu Shattal, Mohammad
    Naffaa, Lena
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (02) : 209 - 216
  • [40] Radiation dose reduction for musculoskeletal computed tomography of the pelvis with preserved image quality
    Zabak, Elaina
    Omar, Hythem
    Boothe, Ethan
    Tenorio, Lulu
    Guild, Jeffrey
    Abbara, Suhny
    Chhabra, Avneesh
    SKELETAL RADIOLOGY, 2019, 48 (03) : 375 - 385