Coronary computed tomography angiography using ultra-low-dose contrast media: radiation dose and image quality

被引:34
|
作者
Komatsu, Sei [1 ]
Kamata, Teruaki [2 ]
Imai, Atsuko [1 ,3 ]
Ohara, Tomoki [1 ]
Takewa, Mitsuhiko [1 ]
Ohe, Ryoko [1 ]
Miyaji, Kazuaki [2 ]
Yoshida, Junichi [1 ]
Kodama, Kazuhisa [1 ]
机构
[1] Amagasaki Cent Hosp, Ctr Cardiovasc, Amagasaki, Hyogo 6610976, Japan
[2] Amagasaki Cent Hosp, Dept Diagnost Imaging, Amagasaki, Hyogo 6610976, Japan
[3] Osaka Univ, Sch Med, Dept Cardiol, Osaka, Japan
来源
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING | 2013年 / 29卷 / 06期
关键词
Coronary computed tomography angiography; Contrast media; Tube potential; CT; PHANTOM; SINGLE;
D O I
10.1007/s10554-013-0201-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To analyze the invasiveness and image quality of coronary CT angiography (CCTA) with 80 kV. We enrolled 181 patients with low body weight and low calcium level. Of these, 154 patients were randomly assigned to 1 of 3 groups: 280 HU/80 kV (n = 51); 350 HU/80 kV (n = 51); or 350 HU/120 kV (n = 52). The amount of contrast media (CM) was decided with a CT number-controlling system. Twenty-seven patients were excluded because of an invalid time density curve by timing bolus. The predicted amount of CM, volume CT dose index, dose-length product, effective dose, image noise, and 5-point image quality were measured. The amounts of CM for the 80 kV/280 HU, 80 kV/350 HU, and 120 kV/350 HU groups were 10 +/- A 4 mL, 15 +/- A 7 mL, and 30 +/- A 6 mL, respectively. Although image noise was greater at 80 than 120 kV, there was no significant difference in image quality between 80 kV/350 HU and 120 kV/350 HU (p = 0.390). There was no significant difference in image quality between 80 kV/280 HU and 80 kV/350 HU (4.4 +/- A 0.7 vs. 4.7 +/- A 0.4, p = 0.056). The amount of CM and effective dose was lower for 80 kV CCTA than for 120 kV CCTA. CCTA at 80 kV/280 HU may decrease the amount of CM and radiation dose necessary while maintaining image quality.
引用
收藏
页码:1335 / 1340
页数:6
相关论文
共 50 条
  • [21] Radiation Dose and Image Quality of a High-Pitch Prospective Spiral First Approach in Coronary Computed Tomography Angiography (CCTA)
    Finck, Tom
    Klambauer, Konstantin
    Hendrich, Eva
    Will, Albrecht
    Martinoff, Stefan
    Hadamitzky, Martin
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2021, 8 (10)
  • [22] Usefulness of Ag Additional Filter on Image Quality and Radiation Dose for Low-Dose Chest Computed Tomography
    Kawamoto, Keishin
    Sato, Hideyuki
    Kogure, Yosuke
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (02) : 236 - 243
  • [23] Low-dose abdominopelvic computed tomography in patients with lymphoma: An image quality and radiation dose reduction study
    Yoon, Sungjin
    Yoo, Kwai Han
    Park, So Hyun
    Kim, Hawk
    Lee, Jae Hoon
    Park, Jinny
    Park, Seong Ho
    Kim, Hwa Jung
    PLOS ONE, 2022, 17 (08):
  • [24] Ultra-low-dose emergency chest computed tomography protocols in three vendors: A technical note
    Mussmann, Bo
    Skov, Peter Marshall
    Lorentzen, Morten H.
    Skjot-Arkil, Helene
    Graumann, Ole
    Andersen, Michael B.
    Jensen, Janni
    ACTA RADIOLOGICA OPEN, 2023, 12 (03)
  • [25] What future for chest x-ray against ultra-low-dose computed tomography?
    Ohana, M.
    Ludes, C.
    Schaal, M.
    Meyer, E.
    Jeung, M. -Y.
    Labani, A.
    Roy, C.
    REVUE DE PNEUMOLOGIE CLINIQUE, 2017, 73 (01) : 3 - 12
  • [26] Ultra-low-dose chest computed tomography without anesthesia in the assessment of pediatric pulmonary diseases
    Dorneles, Cristina Manera
    Pacini, Gabriel Sartori
    Zanon, Matheus
    Altmayer, Stephan
    Watte, Guilherme
    Barros, Marcelo C.
    Marchiori, Edson
    Baldisserotto, Matteo
    Hochhegger, Bruno
    JORNAL DE PEDIATRIA, 2020, 96 (01) : 92 - 99
  • [27] Development of a computed tomography phantom to evaluate radiation dose and image quality
    Gomez Cardona, Daniel
    Estrada Leon, Edgar Santiago
    Zuluaga Santamaria, Alejandro
    Benitez, Luis
    Ramirez Giraldo, Juan Carlos
    2013 PAN AMERICAN HEALTH CARE EXCHANGES (PAHCE), 2013,
  • [28] Individualized Scan Protocols in Abdominal Computed Tomography Radiation Versus Contrast Media Dose Optimization
    Martens, Bibi
    Jost, Gregor
    Mihl, Casper
    Nijssen, Estelle C.
    Wildberger, Joachim E.
    Schmidt, Bernhard
    Flohr, Thomas
    Pietsch, Hubertus
    INVESTIGATIVE RADIOLOGY, 2022, 57 (06) : 353 - 358
  • [29] The optimal monoenergetic spectral image level of coronary computed tomography (CT) angiography on a dual-layer spectral detector CT with half-dose contrast media
    Huang, Xin
    Gao, Sizhe
    Ma, Yue
    Lu, Xiaomei
    Jia, Zheng
    Hou, Yang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (03) : 592 - 603
  • [30] Radiation dose optimization in pediatric temporal bone computed tomography: influence of tube tension on image contrast and image quality
    Nauer, Claude Bertrand
    Zubler, Christoph
    Weisstanner, Christian
    Stieger, Christof
    Senn, Pascal
    Arnold, Andreas
    NEURORADIOLOGY, 2012, 54 (03) : 247 - 254