Primary Stability Determination of Implants Inserted in Sinus Augmented Sites: 1-Step Versus 2-Step Procedure

被引:12
作者
Degidi, Marco [1 ]
Daprile, Giuseppe [1 ]
Piattelli, Adriano [1 ]
机构
[1] Univ G dAnnunzio, Dept Med Oral & Biotechnol Sci, I-66100 Chieti, Italy
关键词
primary stability; sinus lift; insertion torque; resonance frequency analysis; ALVEOLAR BONE HEIGHT; FLOOR AUGMENTATION; MAXILLARY SINUS; FOLLOW-UP; RESONANCE FREQUENCY; SURGICAL TECHNIQUE; AUTOGENOUS BONE; DENTAL IMPLANTS; PLACEMENT; SUCCESS;
D O I
10.1097/ID.0b013e31829f1ef2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives:The aim of this study was to evaluate the primary stability of implants placed immediately after a sinus lift, compared with implants placed in the area treated with a sinus lift 6 months before.Material and Methods:Patients with a residual bone height of at least 4 mm were treated with a 1-stage procedure (group A) and patients with a residual bone height < 4 mm with a 2-stage approach (group B). Sinus lift was always performed with 50% autogenous bone and 50% deproteinized bovine bone mineral. Data recorded included maximum insertion torque (IT), resonance frequency analysis (RFA) values, and bone density, length, and diameter. It was recorded whether an implant was removed within 6 months after insertion.Results:Fourteen patients were included in group A and 16 patients in group B; 96 implants were inserted. Mean IT was 23.77 12.63 Ncm in group A and 26.48 +/- 20.80 Ncm in group B. Mean RFA was 65.25 +/- 4.45 implant stability quotient (ISQ) in group A and 67.92 +/- 10.99 ISQ in group B. No statistically significant differences were found. All implants were osseointegrated.Conclusions:The results show that the implants studied can obtain a sufficient primary stability in both clinical situations without statistically significant differences.
引用
收藏
页码:530 / 533
页数:4
相关论文
共 28 条
[1]   Undersized Implant Site Preparation to Enhance Primary Implant Stability in Poor Bone Density: A Prospective Clinical Study [J].
Alghamdi, Hamdan ;
Anand, Pradeep S. ;
Anil, Sukumaran .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 69 (12) :E506-E512
[2]   Implant stability measurement of delayed and immediately loaded implants during healing. A clinical resonance-frequency analysis study with sandblasted-and-etched ITI implants [J].
Bischof, M ;
Nedir, R ;
Szmukler-Moncler, S ;
Bernard, JP ;
Samson, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (05) :529-539
[3]   Long-Term Success of Sinus Augmentation Using A Synthetic Alloplast: A 20 Patients, 7 Years Clinical Report [J].
Butz, Stan J. ;
Huys, Luc W. J. .
IMPLANT DENTISTRY, 2005, 14 (01) :36-42
[4]  
Chiapasco M, 2009, INT J ORAL MAX IMPL, V24, P237
[5]   Biomechanical evaluation of macro and micro designed screw-type implants: an insertion torque and removal torque study in rabbits [J].
Chowdhary, Ramesh ;
Jimbo, Ryo ;
Thomsen, Christian ;
Carlsson, Lennart ;
Wennerberg, Ann .
CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (03) :342-346
[6]  
da Cunha HA, 2004, INT J ORAL MAX IMPL, V19, P578
[7]  
DEGIDI M, 2012, CLIN IMPLANT DENT R, V40, P521
[8]  
DEGIDI M, CLIN IMPLANT DENT R, DOI DOI 10.1111/J.1708-8208.2011.00392.X
[9]  
Degidi M, 2010, INT J ORAL MAX IMPL, V25, P558
[10]  
Esposito M., 2010, COCHRANE DB SYST REV, V17