Electrochemical immunosensor with Cu(I)/Cu(II)-chitosan-graphene nanocomposite-based signal amplification for the detection of newcastle disease virus

被引:15
作者
Huang, Jiaoling [1 ]
Xie, Zhixun [1 ]
Huang, Yihong [2 ]
Xie, Liji [1 ]
Luo, Sisi [1 ]
Fan, Qing [1 ]
Zeng, Tingting [1 ]
Zhang, Yanfang [1 ]
Wang, Sheng [1 ]
Zhang, Minxiu [1 ]
Xie, Zhiqin [1 ]
Deng, Xianwen [1 ]
机构
[1] Guangxi Vet Res Inst, Guangxi Key Lab Vet Biotechnol, 51 You Ai North Rd, Nanning 530001, Guangxi, Peoples R China
[2] Liuzhou Ctr Anim Dis Control & Prevent, Beijing, Peoples R China
关键词
CHITOSAN; BIOSENSOR; BIENZYME; SORPTION; SERUM; IONS;
D O I
10.1038/s41598-020-70877-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
An electrochemical immunoassay for the ultrasensitive detection of Newcastle disease virus (NDV) was developed using graphene and chitosan-conjugated Cu(I)/Cu(II) (Cu(I)/Cu(II)-Chi-Gra) for signal amplification. Graphene (Gra) was used for both the conjugation of an anti-Newcastle disease virus monoclonal antibody (MAb/NDV) and the immobilization of anti-Newcastle disease virus polyclonal antibodies (PAb/NDV). Cu(I)/Cu(II) was selected as an electroactive probe, immobilized on a chitosan-graphene (Chi-Gra) hybrid material, and detected by differential pulse voltammetry (DPV) after a sandwich-type immune response. Because Gra had a large surface area, many antibodies were loaded onto the electrochemical immunosensor to effectively increase the electrical signal. Additionally, the introduction of Gra significantly increased the loading amount of electroactive probes (Cu(I)/Cu(II)), and the electrical signal was further amplified. Cu(I)/Cu(II) and Cu(I)/Cu(II)-Chi-Gra were compared in detail to characterize the signal amplification ability of this platform. The results showed that this immunosensor exhibited excellent analytical performance in the detection of NDV in the concentration range of 10(0.13) to 10(5.13) EID50/0.1 mL, and it had a detection limit of 10(0.68) EID50/0.1 mL, which was calculated based on a signal-to-noise (S/N) ratio of 3. The resulting immunosensor also exhibited high sensitivity, good reproducibility and acceptable stability.
引用
收藏
页数:12
相关论文
共 35 条
[1]   A multiplex reverse transcription-polymerase chain reaction assay for Newcastle disease virus and avian pneumovirus (Colorado strain) [J].
Ali, A ;
Reynolds, DL .
AVIAN DISEASES, 2000, 44 (04) :938-943
[2]   Electrochemical immunosensor based on chitosan/conductive carbon black composite modified disposable ITO electrode: An analytical platform for p53 detection [J].
Aydin, Elif Burcu ;
Aydin, Muhammet ;
Sezginturk, Mustafa Kemal .
BIOSENSORS & BIOELECTRONICS, 2018, 121 :80-89
[3]   A highly selective electrochemical immunosensor based on conductive carbon black and star PGMA polymer composite material for IL-8 biomarker detection in human serum and saliva [J].
Aydin, Muhammet ;
Aydin, Elif Burcu ;
Sezginturk, Mustafa Kemal .
BIOSENSORS & BIOELECTRONICS, 2018, 117 :720-728
[4]   Electrochemical Aflatoxin B1 immunosensor based on the use of graphene quantum dots and gold nanoparticles [J].
Bhardwaj, Hema ;
Pandey, Manoj Kumar ;
Rajesh ;
Sumana, Gajjala .
MICROCHIMICA ACTA, 2019, 186 (08)
[5]   Preparation, Modification, Characterization, and Biosensing Application of Nanoporous Gold Using Electrochemical Techniques [J].
Bhattarai, Jay K. ;
Neupane, Dharmendra ;
Nepal, Bishal ;
Mikhaylov, Vasilii ;
Demchenko, Alexei V. ;
Stine, Keith J. .
NANOMATERIALS, 2018, 8 (03)
[6]   A review of virulent Newcastle disease viruses in the United States and the role of wild birds in viral persistence and spread [J].
Brown, Vienna R. ;
Bevins, Sarah N. .
VETERINARY RESEARCH, 2017, 48
[7]   Development of an electrochemical biosensor for the determination of triglycerides in serum samples based on a lipase/magnetite-chitosan/copper oxide nanoparticles/multiwalled carbon nanotubes/pectin composite [J].
Di Tocco, A. ;
Robledo, S. N. ;
Osuna, Y. ;
Sandoval-Cortez, J. ;
Granero, A. M. ;
Vettorazzi, N. R. ;
Martinez, J. L. ;
Segura, E. P. ;
Ilina, A. ;
Zon, M. A. ;
Arevalo, F. J. ;
Fernandez, H. .
TALANTA, 2018, 190 :30-37
[8]   Electrochemical immunosensors - A powerful tool for analytical applications [J].
Felix, Fabiana S. ;
Angnes, Lucio .
BIOSENSORS & BIOELECTRONICS, 2018, 102 :470-478
[9]   Newcastle disease virus: Current status and our understanding [J].
Ganar, Ketan ;
Das, Moushumee ;
Sinha, Sugandha ;
Kumar, Sachin .
VIRUS RESEARCH, 2014, 184 :71-81
[10]   The rise of graphene [J].
Geim, A. K. ;
Novoselov, K. S. .
NATURE MATERIALS, 2007, 6 (03) :183-191