A Fully Automated Method for Segmenting Arteries and Quantifying Vessel Radii on Magnetic Resonance Angiography Images of Varying Projection Thickness

被引:11
|
作者
Avadiappan, Sivakami [1 ]
Payabvash, Seyedmehdi [1 ,3 ]
Morrison, Melanie A. [1 ]
Jakary, Angela [1 ]
Hess, Christopher P. [1 ,2 ]
Lupo, Janine M. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Dept Neurol, San Francisco, CA USA
[3] Yale Sch Med, Dept Radiol & Biomed Imaging, New Haven, CT USA
关键词
MRA; segmentation; Frangi; vessels; radii; MAXIMUM INTENSITY PROJECTION; TIME-OF-FLIGHT; MRA; SEGMENTATION; ACCURACY;
D O I
10.3389/fnins.2020.00537
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Purpose Precise quantification of cerebral arteries can help with differentiation and prognostication of cerebrovascular disease. Existing image processing and segmentation algorithms for magnetic resonance angiography (MRA) are limited to the analysis of either 2D maximum intensity projection images or the entire 3D volume. The goal of this study was to develop a fully automated, hybrid 2D-3D method for robust segmentation of arteries and accurate quantification of vessel radii using MRA at varying projection thicknesses. Methods A novel algorithm that employs an adaptive Frangi filter for segmentation of vessels followed by estimation of vessel radii is presented. The method was evaluated on MRA datasets and corresponding manual segmentations from three healthy subjects for various projection thicknesses. In addition, the vessel metrics were computed in four additional subjects. Three synthetically generated angiographic datasets resembling brain vasculature were also evaluated under different noise levels. Dice similarity coefficient, Jaccard Index, F-score, and concordance correlation coefficient were used to measure the segmentation accuracy of manual versus automatic segmentation. Results Our new adaptive filter rendered accurate representations of vessels, maintained accurate vessel radii, and corresponded better to manual segmentation at different projection thicknesses than prior methods. Validation with synthetic datasets under low contrast and noisy conditions revealed accurate quantification of vessels without distortions. Conclusion We have demonstrated a method for automatic segmentation of vascular trees and the subsequent generation of a vessel radii map. This novel technique can be applied to analyze arterial structures in healthy and diseased populations and improve the characterization of vascular integrity.
引用
收藏
页数:14
相关论文
共 2 条
  • [1] Calibration of a semi-automated segmenting method for quantification of adipose tissue compartments from magnetic resonance images of mice
    Garteiser, Philippe
    Doblas, Sabrina
    Towner, Rheal A.
    Griffin, Timothy M.
    METABOLISM-CLINICAL AND EXPERIMENTAL, 2013, 62 (11): : 1686 - 1695
  • [2] An efficient and fast computer-aided method for fully automated diagnosis of meniscal tears from magnetic resonance images
    Saygili, Ahmet
    Albayrak, Songul
    ARTIFICIAL INTELLIGENCE IN MEDICINE, 2019, 97 : 118 - 130