Digital distance protection of transmission lines in the presence of SSSC

被引:47
作者
Ghorbani, Amir [1 ]
Mozafari, Babak [1 ]
Ranjbar, Ali Mohammad [2 ]
机构
[1] Islamic Azad Univ, Sci & Res Branch, Dept Elect Engn, Tehran, Iran
[2] Sharif Univ Technol, Dept Elect Engn, Tehran, Iran
关键词
Distance relay; Trip boundary; Static Synchronous Series Compensator (SSSC); PERFORMANCE; ALGORITHM; RELAYS; IMPACT;
D O I
10.1016/j.ijepes.2012.05.035
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper the impact of Static Synchronous Series Compensator (SSSC) on the impedance calculated by distance relay is investigated. Analytical results are presented and verified by detailed simulations. Six different phase to phase and phase to ground measuring units of the distance relay are simulated to resemble the behavior of the relay. It is shown in this paper that zero sequence of the injected voltage by 48 pulse SSSC converter has the most impact on the apparent impedance seen by the phase to ground fault measuring unit and cause under reaching of distance relay. It can be concluded from the results that SSSC located in the middle of the transmission line cause to divide trip characteristics of distance relay into two separate parts. It is also shown that the over-reaching operation of distance relay might happen in some cases in the presence of SSSC. All the detailed simulations are carried out in MATLAB/Simulink environment. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:712 / 719
页数:8
相关论文
共 17 条
[1]  
Dash P. K., 2000, P IEEE POW ENG WINT, V3, P1967
[2]   Adaptive relay setting for flexible AC transmission systems (FACTS) [J].
Dash, PK ;
Pradhan, AK ;
Panda, G ;
Liew, AC .
IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (01) :38-43
[3]   Distance protection in the presence of unified power flow controller [J].
Dash, PK ;
Pradhan, AK ;
Panda, G .
ELECTRIC POWER SYSTEMS RESEARCH, 2000, 54 (03) :189-198
[4]   Operation of impedance protection relays with the STATCOM [J].
El-Arroudi, K ;
Joos, G ;
McGillis, DT .
IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (02) :381-387
[5]   Novel controllers for the 48-pulse VSCSTATCOM and SSSC for voltage regulation and reactive power compensation [J].
El-Moursi, MS ;
Sharaf, AM .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (04) :1985-1997
[6]   Impact of SVC on the protection of transmission lines [J].
Ghorbani, Amir ;
Khederzadeh, Mojtaba ;
Mozafari, Babak .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 42 (01) :702-709
[7]   Comparing Impact of STATCOM and SSSC on the Performance of Digital Distance Relay [J].
Ghorbani, Amir .
JOURNAL OF POWER ELECTRONICS, 2011, 11 (06) :890-896
[8]  
Hingorani N. G., 2000, Understanding FACTS Concepts and Technology of Flexible AC Transmission Systems
[9]   Impact of TCSC on the protection of transmission lines [J].
Khederzadeh, M ;
Sidhu, TS .
IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (01) :80-87
[10]  
Khederzadeh M., 2009, IEEE PES GEN M CALG