Using a multilayer printed circuit board as position sensing electrode in a triple-GEM detector

被引:1
作者
Marinho, PRB [1 ]
Barbosa, AF
Guedes, GP
机构
[1] Ctr Brasileiro Pesquisas Fis, Lab Sistemas Deteccao, BR-22290180 Rio De Janeiro, RJ, Brazil
[2] Univ Estadual Feira de Santana, Dept Mat Condensada, BR-44031460 Feira De Santana, BA, Brazil
关键词
delay line readout; gas electron multiplier; gaseous imaging detector; two-dimensional (2-D) readout;
D O I
10.1109/TNS.2005.862800
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The development of a triple-GEM imaging detector is reported. The triple-GEM detector provides two-dimensional (2-D) localization of ionizing events making use of a multilayer printed circuit board (X&Y anode) for position readout. Two-dimensional localization is achieved by associating one discrete delay line to each spatial coordinate. Results referring to differential nonlinearity (DNL), integral nonlinearity (INL) and spatial resolution are presented. The detector has been operated with Ar/Xe/CO2 (64/16/20) gas mixture at atmospheric pressure. 5.9 keV (Fe-55 source) photons were used to characterize the detector. The feasibility of the imaging technique is demonstrated and the major issues are adressed.