Three-dimensional printed millifluidic devices for zebrafish embryo tests

被引:50
作者
Zhu, Feng [1 ]
Skommer, Joanna [1 ]
Macdonald, Niall P. [2 ]
Friedrich, Timo [3 ]
Kaslin, Jan [3 ]
Wlodkowic, Donald [1 ,4 ,5 ]
机构
[1] RMIT Univ, Sch Appl Sci, BioMEMS Res Grp, Melbourne, Vic 3083, Australia
[2] Univ Glasgow, Sch Engn, Glasgow G12 8QQ, Lanark, Scotland
[3] Monash Univ, Australian Regenerat Med Inst, Clayton, Vic 3800, Australia
[4] RMIT Univ, Ctr Addit Mfg, Melbourne, Vic 3083, Australia
[5] RMIT Univ, Ctr Environm Sustainabil & Remediat EnSuRe, Melbourne, Vic 3083, Australia
来源
BIOMICROFLUIDICS | 2015年 / 9卷 / 04期
基金
澳大利亚国家健康与医学研究理事会; 澳大利亚研究理事会;
关键词
MICROFLUIDIC DEVICES; CHIP; FUTURE; LAB;
D O I
10.1063/1.4927379
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Implementations of Lab-on-a-Chip technologies for in-situ analysis of small model organisms and embryos (both invertebrate and vertebrate) are attracting an increasing interest. A significant hurdle to widespread applications of microfluidic and millifluidic devices for in-situ analysis of small model organisms is the access to expensive clean room facilities and complex microfabrication technologies. Furthermore, these resources require significant investments and engineering know-how. For example, poly(dimethylsiloxane) soft lithography is still largely unattainable to the gross majority of biomedical laboratories willing to pursue development of chip-based platforms. They often turn instead to readily available but inferior classical solutions. We refer to this phenomenon as workshop-to-bench gap of bioengineering science. To tackle the above issues, we examined the capabilities of commercially available Multi-Jet Modelling (MJM) and Stereolithography (SLA) systems for low volume fabrication of optical-grade millifluidic devices designed for culture and biotests performed on millimetre-sized specimens such as zebrafish embryos. The selected 3D printing technologies spanned a range from affordable personal desktop systems to high-end professional printers. The main motivation of our work was to pave the way for off-the-shelf and user-friendly 3D printing methods in order to rapidly and inexpensively build optical-grade millifluidic devices for customized studies on small model organisms. Compared with other rapid prototyping technologies such as soft lithography and infrared laser micromachining in poly(methyl methacrylate), we demonstrate that selected SLA technologies can achieve user-friendly and rapid production of prototypes, superior feature reproduction quality, and comparable levels of optical transparency. A caution need to be, however, exercised as majority of tested SLA and MJM resins were found toxic and caused significant developmental abnormalities in zebrafish embryos. Taken together, our data demonstrate that SLA technologies can be used for rapid and accurate production of devices for biomedical research. However, polymer biotoxicity needs to be carefully evaluated. (C) 2015 AIP Publishing LLC.
引用
收藏
页数:10
相关论文
共 30 条
  • [1] Integrated chip-based physiometer for automated fish embryo toxicity biotests in pharmaceutical screening and ecotoxicology
    Akagi, Jin
    Zhu, Feng
    Hall, Chris J.
    Crosier, Kathryn E.
    Crosier, Philip S.
    Wlodkowic, Donald
    [J]. CYTOMETRY PART A, 2014, 85A (06) : 537 - 547
  • [2] Miniaturized Embryo Array for Automated Trapping, Immobilization and Microperfusion of Zebrafish Embryos
    Akagi, Jin
    Khoshmanesh, Khashayar
    Evans, Barbara
    Hall, Chris J.
    Crosier, Kathryn E.
    Cooper, Jonathan M.
    Crosier, Philip S.
    Wlodkowic, Donald
    [J]. PLOS ONE, 2012, 7 (05):
  • [3] [Anonymous], 2013, OECD Guidelines No. 236: Fish Embryo Acute Toxicity (FET) Test, DOI DOI 10.3109/9781841848570-66
  • [4] Mail-order microfluidics: evaluation of stereolithography for the production of microfluidic devices
    Au, Anthony K.
    Lee, Wonjae
    Folch, Albert
    [J]. LAB ON A CHIP, 2014, 14 (07) : 1294 - 1301
  • [5] Open Labware: 3-D Printing Your Own Lab Equipment
    Baden, Tom
    Chagas, Andre Maia
    Gage, Greg
    Marzullo, Timothy
    Prieto-Godino, Lucia L.
    Euler, Thomas
    [J]. PLOS BIOLOGY, 2015, 13 (03):
  • [6] Immunology on chip: Promises and opportunities
    Baratchi, Sara
    Khoshmanesh, Khashayar
    Sacristan, Catarina
    Depoil, David
    Wlodkowic, Donald
    McIntyre, Peter
    Mitchell, Arnan
    [J]. BIOTECHNOLOGY ADVANCES, 2014, 32 (02) : 333 - 346
  • [7] Hype, hope and hubris: the quest for the killer application in microfluidics
    Becker, Holger
    [J]. LAB ON A CHIP, 2009, 9 (15) : 2119 - 2122
  • [8] Discrete elements for 3D microfluidics
    Bhargava, Krisna C.
    Thompson, Bryant
    Malmstadt, Noah
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2014, 111 (42) : 15013 - 15018
  • [9] Making sense of 3-D printing: Creating a map of additive manufacturing products and services
    Conner, Brett P.
    Manogharan, Guha P.
    Martof, Ashley N.
    Rodomsky, Lauren M.
    Rodomsky, Caitlyn M.
    Jordan, Dakesha C.
    Limperos, James W.
    [J]. Additive Manufacturing, 2014, 1 : 64 - 76
  • [10] Lantada AD, 2012, ANNU REV BIOMED ENG, V14, P73, DOI [10.1146/annurev.bioeng-071811-150112, 10.1146/annurev-bioeng-071811-150112]