A Novel Zernike Application to Differentiate Between Three-dimensional Corneal Thickness of Normal Corneas and Corneas With Keratoconus

被引:17
作者
Shetty, Rohit [1 ]
Matalia, Himanshu [1 ]
Srivatsa, Purnima [1 ]
Ghosh, Arkasubhra [2 ]
Dupps, William J., Jr. [3 ,4 ]
Roy, Abhijit Sinha [2 ]
机构
[1] Narayana Nethralaya, Cornea & Refract Surg Div, Bangalore, Karnataka, India
[2] Narayana Nethralaya, Imaging Biomech & Math Modeling Solut, Bangalore, Karnataka, India
[3] Cleveland Clin, Cole Eye Inst, Cleveland, OH 44106 USA
[4] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
关键词
FREQUENCY DIGITAL ULTRASOUND; OPTICAL COHERENCE TOMOGRAPHY; PHOTOREFRACTIVE KERATECTOMY; CONE LOCATION; BIOMECHANICS; TOPOGRAPHY; EPITHELIUM; ARTEMIS; DISPLAY;
D O I
10.1016/j.ajo.2015.06.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate a novel Zernike algorithm to differentiate 3-dimensional (3-D) corneal thickness distribution of corneas with keratoconus (KC) from normal corneas. DESIGN: A retrospective development and evaluation of a diagnostic approach. METHODS: Corneal tomography with Scheimpflug imaging was performed in normal (43 eyes) and KC (85 eyes) corneas. Axial and tangential cone location magnitude index (axial CLMI and tangential CLMI, respectively) of the anterior and posterior surface were calculated. The aberrations of the anterior corneal surface were analyzed with Zernike polynomials. Pachymetric Zernike analyses (PZA) were used to map the 3-D thickness distribution of the cornea. Logistic regression was performed to develop a diagnostic procedure for KC using CLMI, PZA, and aberrations. A receiver operating characteristic curve was constructed for each regression model. Corneal volume was also compared between normal and KC corneas. Only the central 5 mm zone was used for all analyses. " RESULTS: Among the PZA coefficients, second-and third-order root mean squares of PZA coefficients were the best predictors of KC corneas (P<.0001). Among the CLMI variables, axial CLMI of anterior and tangential CLMI of posterior surface were the best predictors of KC (P<.0001). Among the Zernike corneal aberration coefficients, second-and third-order root mean squares of coefficients were the best predictors of KC (P<.0001). Sensitivity and specificity of Zernike corneal aberrations, CLMI, and PZA logistic regression model were similar (P>.05). CONCLUSIONS: The entire 3-D corneal thickness was mapped with Zernike. The PZA method was comparable to CLMI and anterior corneal wavefront aberrations in detecting KC. (C) 2015 by Elsevier Inc. All rights reserved.
引用
收藏
页码:453 / 462
页数:10
相关论文
共 22 条
[1]   Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconus [J].
Ambrosio, Renato, Jr. ;
Alonso, Ruiz Simonato ;
Luz, Allan ;
Coca Velarde, Luis Guillermo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) :1851-1859
[2]   Scheimpflug imaging for laser refractive surgery [J].
Ambrosio, Renato, Jr. ;
Valbon, Bruno F. ;
Faria-Correia, Fernando ;
Ramos, Isaac ;
Luz, Allan .
CURRENT OPINION IN OPHTHALMOLOGY, 2013, 24 (04) :310-320
[3]   Novel Pachymetric Parameters Based on Corneal Tomography for Diagnosing Keratoconus [J].
Ambrosio, Renato, Jr. ;
Caiado, Ana Laura C. ;
Guerra, Frederico P. ;
Louzada, Ricardo ;
Roy, Abhijit Sinha ;
Luz, Allan ;
Dupps, William J. ;
Belin, Michael W. .
JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (10) :753-758
[4]   Defining subclinical keratoconus using corneal first-surface higher-order aberrations [J].
Buehren, Jens ;
Kuehne, Christoph ;
Kohnen, Thomas .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (03) :381-389
[5]   Detection of Subclinical Keratoconus by Using Corneal Anterior and Posterior Surface Aberrations and Thickness Spatial Profiles [J].
Buehren, Jens ;
Kook, Daniel ;
Yoon, Geunyoung ;
Kohnen, Thomas .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (07) :3424-3432
[6]   Contribution of the corneal epithelium to anterior corneal topography in patients having myopic photorefractive keratectomy [J].
Gatinel, Damien ;
Racine, Louis ;
Hoang-Xuan, Thanh .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (11) :1860-1865
[7]   Automatic Segmentation of the Central Epithelium Imaged With Three Optical Coherence Tomography Devices [J].
Ge, Lili ;
Shen, Meixiao ;
Tao, Aizhu ;
Wang, Jianhua ;
Dou, Guopeng ;
Lu, Fan .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2012, 38 (03) :150-157
[8]   Discriminant Value of Custom Ocular Response Analyzer Waveform Derivatives in Keratoconus [J].
Hallahan, Katie M. ;
Roy, Abhijit Sinha ;
Ambrosio, Renato, Jr. ;
Salomao, Marcella ;
Dupps, William J., Jr. .
OPHTHALMOLOGY, 2014, 121 (02) :459-468
[9]   CLMI - The Cone Location and Magnitude Index [J].
Mahmoud, Ashraf M. ;
Roberts, Cynthia J. ;
Lembach, Richard G. ;
Twa, Michael D. ;
Herderick, Edward E. ;
McMahon, Timothy T. .
CORNEA, 2008, 27 (04) :480-487
[10]   Expanding the Cone Location and Magnitude Index to Include Corneal Thickness and Posterior Surface Information for the Detection of Keratoconus [J].
Mahmoud, Ashraf M. ;
Nunez, Maria X. ;
Blanco, Claudia ;
Koch, Douglas D. ;
Wang, Li ;
Weikert, Mitchell P. ;
Frueh, Beatrice E. ;
Tappeiner, Christoph ;
Twa, Michael D. ;
Roberts, Cynthia J. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (06) :1102-1111