Intercross real-time control strategy in alternating activated sludge process for short-cut biological nitrogen removal treating domestic wastewater

被引:16
作者
Wang Shuying [1 ]
Zhang Shanfeng [1 ,2 ]
Peng Chengyao [1 ]
Takigawa, Akio [3 ]
机构
[1] Beijing Univ Technol, Key Lab Beijing Water Qual Sci & Water Environm R, Beijing 100022, Peoples R China
[2] Beijing Municipal Engn Profess Design Inst Co Ltd, Beijing 100037, Peoples R China
[3] Maebashi Inst Technol, Dept Civil & Environm Engn, Gunma 3710816, Japan
关键词
alternating activated sludge process; continuous-flow; real-time control; nitrification;
D O I
10.1016/S1001-0742(08)62193-2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To develop technically feasible and economically favorable dynamic process control (DPC) strategies for an alternating activated sludge (AAS) system, a bench-scale continuous-flow alternating aerobic and anoxic reactor, performing short-cut nitrogen removal from real domestic wastewater was operated under different control strategies for more than five months. A fixed-time control (FTC) study showed that bending-points on pH and oxidation-reduction potential (ORP) profiles accurately coincided with the major biological activities. "Ammonia valley" on the pH profile represented the end of nitrification, whereas, the "nitrite knee" on the ORP profile and "nitrite apex" on the pH profile both indicated the end of denitrification. Therefore, a new reliable and effective real-time control strategy was developed using pH and ORP as control parameters, to improve the performance of the AAS process. The online control strategy could achieve up to 87% of the total nitrogen (TN) removal efficiency on an average, and saving approximately 20% aeration energy, as compared to the conventional steady-state control systems. Moreover, stable short-cut nitrification and denitrification were successfully achieved with an average nitrite accumulation ratio of above 95%.
引用
收藏
页码:957 / 963
页数:7
相关论文
共 24 条
  • [1] Monitoring and control of biological nutrient removal in a Sequencing Batch Reactor
    Akin, BS
    Ugurlu, A
    [J]. PROCESS BIOCHEMISTRY, 2005, 40 (08) : 2873 - 2878
  • [2] USE OF PH AS CONTROL PARAMETER FOR AEROBIC/ANOXIC SLUDGE-DIGESTION
    ALGHUSAIN, I
    HAO, OJ
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1995, 121 (03): : 225 - 235
  • [3] ALGHUSAIN IA, 1994, WATER SCI TECHNOL, V30, P159
  • [4] [Anonymous], 1995, Standard methods for examination of water and waste water, V19th
  • [5] Chachuat B, 2005, CHEM ENG PROCESS, V44, P593, DOI 10.1016/j.cep.2004.08.002
  • [6] CHAPENTIER J, 1998, WATER SCI TECHNOL, V38, P197
  • [7] Approach for a novel control strategy for simultaneous nitrification/denitrification in activated sludge reactors
    Fuerhacker, M
    Bauer, H
    Ellinger, R
    Sree, U
    Schmid, H
    Zibuschka, F
    Puxbaum, H
    [J]. WATER RESEARCH, 2000, 34 (09) : 2499 - 2506
  • [8] HAO OJ, 1991, J CHEM TECHNOL BIOT, V52, P457
  • [9] HYUNOOK K, 2000, CONTROL ENG PRACT, V8, P279
  • [10] pH and oxidation-reduction potential control strategy for optimization of nitrogen removal in an alternating aerobic-anoxic system
    Kim, H
    Hao, OJ
    [J]. WATER ENVIRONMENT RESEARCH, 2001, 73 (01) : 95 - 102