EFFECT OF THERMAL STORAGE ON THE COOLING CAPACITY OF AMBIENT SOURCES

被引:0
作者
Robinson, Brian S. [1 ]
Sharp, M. Keith [1 ]
机构
[1] Univ Louisville, Louisville, KY 40292 USA
来源
PROCEEDINGS OF THE ASME 8TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2014, VOL 2 | 2014年
关键词
VENTILATION; BUILDINGS;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ambient sources, including ambient air at dry-bulb and wet-bulb temperature, ground temperature and night sky temperature, were evaluated for their potential to provide space cooling in locations across the U.S. While ground temperature is constant beyond a certain depth, the other sources have fluctuating temperatures, which present intermittent potentials for cooling. Simultaneously, cooling demands also fluctuate with outdoor temperature. Thermal storage can bridge intervals of time during which cooling is needed in the building, but ambient source temperature is too high to provide cooling. The duration of these intervals and the thermal storage capacity required to meet cooling needs based on ambient source potential prior to the interval were quantified for all eleven climate zones across the continental U.S using TMY3 weather data. The thermal storage capacity required to meet the entire annual cooling load is dictated by the span of time without ambient source cooling potential that has the greatest ratio of cooling load to ambient source cooling potential prior to the interval. This maximum thermal storage capacity, normalized by building overall loss coefficient, (this ratio has units of time) was one day or less for night sky temperature for all but the three warmest climates. This ratio was one day or less for wet-bulb temperature for four locations, and for dry-bulb temperature for only two locations. Ground temperature provided continuous cooling potential in all but the three warmest climates, where ground temperature was warmer than the indoor comfort temperature. Because the maximum thermal storage capacity was determined in most climates by uncommon and infrequent coincidence of high cooling demand and low ambient source cooling potential, smaller thermal storage provided substantial cooling capacity in most cases. For instance, ten percent of the maximum supplied 99% of the cooling load for the dry-bulb ambient air source in Albuquerque, and 0.1% of the maximum served over 90% of the cooling load with night sky radiation in New Orleans and Phoenix. While considerable development of hardware and control algorithms to utilize ambient sources for space cooling has occurred, this study shows the potential of these sources to further reduce demands for conventional energy for space cooling across a wide range of climates.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] DYNAMIC SIMULATION OF THERMAL CAPACITY AND CHARGING/DISCHARGING PERFORMANCE FOR SENSIBLE HEAT STORAGE IN BUILDING WALL MASS
    Wolisz, Henryk
    Harb, Hassan
    Matthes, Peter
    Streblow, Rita
    Mueller, Dirk
    BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 2716 - 2723
  • [42] Modified lime-cement plasters with enhanced thermal and hygric storage capacity for moderation of interior climate
    Pavlik, Zbysek
    Fort, Jan
    Pavlikova, Milena
    Pokorny, Jaroslav
    Trnik, Anton
    Cerny, Robert
    ENERGY AND BUILDINGS, 2016, 126 : 113 - 127
  • [43] Thermal performance analysis of a flat slab phase change thermal storage unit with liquid-based heat transfer fluid for cooling applications
    Liu, Ming
    Bruno, Frank
    Saman, Wasim
    SOLAR ENERGY, 2011, 85 (11) : 3017 - 3027
  • [44] Cost estimation and sensitivity analysis of a latent thermal energy storage system for supplementary cooling of air cooled condensers
    Pan, Chunjian
    Vermaak, Natasha
    Romero, Carlos
    Neti, Sudhakar
    Hoenig, Sean
    Chen, Chien-Hua
    Bonner, Richard, III
    APPLIED ENERGY, 2018, 224 : 52 - 68
  • [45] Thermosiphon radiation capacity modelling for the cooling of dwellings
    Porta-Gandara, M. A.
    Fernandez-Zayas, J. L.
    Chargoy-del-Valle, N.
    CASE STUDIES IN THERMAL ENGINEERING, 2020, 21
  • [46] Effect mechanism of wind shields on the thermal performance for mechanical draft wet cooling towers
    Chen, Xuehong
    Sun, Fengzhong
    Yang, Shasha
    Xia, Lijiang
    Zhang, Xiaoyu
    APPLIED THERMAL ENGINEERING, 2023, 219
  • [47] Cooling Thermal Comfort and Efficiency Parameters of Ceiling Panels, Underfloor Cooling, Fan-Assisted Radiators, and Fan Coil
    Vosa, Karl-Villem
    Ferrantelli, Andrea
    Kurnitski, Jarek
    ENERGIES, 2022, 15 (11)
  • [48] 3D numerical model for transient simulations of floor cooling capacity and thermal comfort in a thermally heterogeneous room
    Pawlak, F.
    Koczyk, H.
    Gorka, A.
    BUILDING AND ENVIRONMENT, 2023, 245
  • [49] Application of Thermal Labyrinth System to Reduce Heating and Cooling Energy Consumption
    Rim, Minyeop
    Sung, Uk-Joo
    Kim, Taeyeon
    ENERGIES, 2018, 11 (10)
  • [50] Thermal environment and thermal comfort built by decoupled radiant cooling units with low radiant cooling temperature
    Liang, Yuying
    Zhang, Nan
    Wu, Huijun
    Xu, Xinhua
    Du, Ke
    Yang, Jianming
    Sun, Qin
    Dong, Kaijun
    Huang, Gongsheng
    BUILDING AND ENVIRONMENT, 2021, 206 (206)