EFFECT OF THERMAL STORAGE ON THE COOLING CAPACITY OF AMBIENT SOURCES
被引:0
|
作者:
Robinson, Brian S.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Louisville, Louisville, KY 40292 USAUniv Louisville, Louisville, KY 40292 USA
Robinson, Brian S.
[1
]
Sharp, M. Keith
论文数: 0引用数: 0
h-index: 0
机构:
Univ Louisville, Louisville, KY 40292 USAUniv Louisville, Louisville, KY 40292 USA
Sharp, M. Keith
[1
]
机构:
[1] Univ Louisville, Louisville, KY 40292 USA
来源:
PROCEEDINGS OF THE ASME 8TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2014, VOL 2
|
2014年
关键词:
VENTILATION;
BUILDINGS;
D O I:
暂无
中图分类号:
TU [建筑科学];
学科分类号:
0813 ;
摘要:
Ambient sources, including ambient air at dry-bulb and wet-bulb temperature, ground temperature and night sky temperature, were evaluated for their potential to provide space cooling in locations across the U.S. While ground temperature is constant beyond a certain depth, the other sources have fluctuating temperatures, which present intermittent potentials for cooling. Simultaneously, cooling demands also fluctuate with outdoor temperature. Thermal storage can bridge intervals of time during which cooling is needed in the building, but ambient source temperature is too high to provide cooling. The duration of these intervals and the thermal storage capacity required to meet cooling needs based on ambient source potential prior to the interval were quantified for all eleven climate zones across the continental U.S using TMY3 weather data. The thermal storage capacity required to meet the entire annual cooling load is dictated by the span of time without ambient source cooling potential that has the greatest ratio of cooling load to ambient source cooling potential prior to the interval. This maximum thermal storage capacity, normalized by building overall loss coefficient, (this ratio has units of time) was one day or less for night sky temperature for all but the three warmest climates. This ratio was one day or less for wet-bulb temperature for four locations, and for dry-bulb temperature for only two locations. Ground temperature provided continuous cooling potential in all but the three warmest climates, where ground temperature was warmer than the indoor comfort temperature. Because the maximum thermal storage capacity was determined in most climates by uncommon and infrequent coincidence of high cooling demand and low ambient source cooling potential, smaller thermal storage provided substantial cooling capacity in most cases. For instance, ten percent of the maximum supplied 99% of the cooling load for the dry-bulb ambient air source in Albuquerque, and 0.1% of the maximum served over 90% of the cooling load with night sky radiation in New Orleans and Phoenix. While considerable development of hardware and control algorithms to utilize ambient sources for space cooling has occurred, this study shows the potential of these sources to further reduce demands for conventional energy for space cooling across a wide range of climates.
机构:
Ryerson Univ, Dept Mech & Ind Engn, 350 Victoria St, Toronto, ON M5B 2K3, CanadaRyerson Univ, Dept Mech & Ind Engn, 350 Victoria St, Toronto, ON M5B 2K3, Canada
Rad, Farzin M.
Fung, Alan S.
论文数: 0引用数: 0
h-index: 0
机构:
Ryerson Univ, Dept Mech & Ind Engn, 350 Victoria St, Toronto, ON M5B 2K3, CanadaRyerson Univ, Dept Mech & Ind Engn, 350 Victoria St, Toronto, ON M5B 2K3, Canada
机构:
Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R ChinaHong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
Fang, Yuhang
Niu, Jianlei
论文数: 0引用数: 0
h-index: 0
机构:
Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
Univ Sydney, Sch Architecture Design & Planning, Sydney, NSW, Australia
Univ Sydney, Sch Civil Engn, Sydney, NSW, AustraliaHong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
Niu, Jianlei
Deng, Shiming
论文数: 0引用数: 0
h-index: 0
机构:
Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R ChinaHong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
机构:
Soongsil Univ, Dept Architectural Engn, Seoul 06978, South KoreaSoongsil Univ, Dept Architectural Engn, Seoul 06978, South Korea
Jeong, Su-Gwang
Lee, Taemin
论文数: 0引用数: 0
h-index: 0
机构:
Soongsil Univ, Dept Architectural Engn, Seoul 06978, South KoreaSoongsil Univ, Dept Architectural Engn, Seoul 06978, South Korea
Lee, Taemin
Lee, Jeonghun
论文数: 0引用数: 0
h-index: 0
机构:
Pass House Inst Korea, Dept Urban & Architectural Environm Design, Seoul 05520, South KoreaSoongsil Univ, Dept Architectural Engn, Seoul 06978, South Korea