Rigid contact lens fitting relationships in keratoconus

被引:41
作者
Edrington, TB [1 ]
Szczotka, LB [1 ]
Barr, JT [1 ]
Achtenberg, JF [1 ]
Burger, DS [1 ]
Janoff, AM [1 ]
Olafsson, HE [1 ]
Chun, MW [1 ]
Boyle, JW [1 ]
Gordon, MO [1 ]
Zadnik, K [1 ]
机构
[1] So Calif Coll Optometry, Fullerton, CA USA
关键词
keratoconus; contact lenses; FDACL; keratometry; CLEK study;
D O I
10.1097/00006324-199910000-00020
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. Although the influence of flat-fitting contact lenses on corneal scarring in keratoconus is frequently debated, the current standard of care with regard to the apical fitting relationship in keratoconus remains undocumented. Methods. Patients were examined at baseline in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study (N = 1209). Patients wearing a rigid contact lens in one or both eyes (N = 808) had their habitual rigid contact tenses analyzed, and the fluorescein patterns and base curves were compared to the first definite apical clearance lens (FDACL). The FDACL is the flattest lens in the CLEK Study trial lens set that exhibits an apical clearance fluorescein pattern. For patients wearing a rigid contact lens in both eyes, one eye was selected randomly for analysis. Results, Twelve percent of the rigid contact lens-wearing eyes were wearing tenses fitted with apical clearance based upon the clinician's fluorescein pattern interpretation. The remainder (88%) was wearing lenses fitted with apical touch. For mild (steep keratometric reading <45 D) keratoconus corneas, the mean estimate of the base curve to cornea-fitting relationship was 1.18 D flat (SD +/- 1.84 D); moderate (steep keratometric reading: 45 to 52 D) corneas were fitted on average 2.38 D fiat (SD +/- 2.56 D); and severe (steep keratometric reading >52 D) corneas were fitted an average of 4.01 D flat (SD +/- 4.11 D), Conclusions. Despite the potential risk for corneal scarring imposed by flat-fitting rigid contact lenses, most CLEK Study patients wear fiat-fitting lenses. Overall, rigid lenses were fitted an average of 2.86 D (SD +/- 3.31 D) flatter than the FDACL.
引用
收藏
页码:692 / 699
页数:8
相关论文
共 20 条
[1]  
ARIAS VC, 1959, CONTACTO, V3, P393
[2]  
BENNETT ES, 1986, RIGID GAS PERMEABLE, P297
[3]   ACCURACY OF VIDEOKERATOGRAPHY FOR INSTANTANEOUS RADIUS IN KERATOCONUS [J].
CHAN, JS ;
MANDELL, RB ;
BURGER, DS ;
FUSARO, RE .
OPTOMETRY AND VISION SCIENCE, 1995, 72 (11) :793-799
[4]   CORNEAL ECCENTRICITY AS A TOOL FOR THE DIAGNOSIS OF KERATOCONUS [J].
DAO, CL ;
KOK, JHC ;
BRINKMAN, CJJ ;
VANMIL, CJ .
CORNEA, 1994, 13 (04) :339-344
[5]  
DECUNHA DA, 1993, OPHTHAL PHYSL OPT, V13, P377, DOI 10.1111/j.1475-1313.1993.tb00494.x
[6]  
EDMUND C, 1987, ACTA OPHTHALMOL, V65, P545
[7]  
Edrington TB, 1998, CORNEA, V17, P267, DOI 10.1097/00003226-199805000-00006
[8]  
KORB DR, 1982, J AM OPTOM ASSOC, V53, P199
[9]  
MAEDA N, 1994, INVEST OPHTH VIS SCI, V35, P2749
[10]  
Maguen E, 1983, CLAO J, V9, P57