In vivo evaluation of the kinematics of the long head of the biceps tendon within the pulley: A 3 T MRI motion analysis

被引:2
|
作者
Beitzel, K. [1 ,2 ]
Kirchhoff, C. [3 ]
Beitzel, K. I. [4 ]
Reiser, M. F. [4 ]
Kirchhoff, S. [4 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Orthoped & Sports Orthoped, D-80290 Munich, Germany
[2] Trauma Ctr Murnau, Dept Trauma & Orthoped Surg, Murnau, Germany
[3] Tech Univ Munich, Klinikum Rechts Isar, Dept Trauma Surg, D-80290 Munich, Germany
[4] Klinikum Ludwig Maximilians Univ Munchen, Inst Clin Radiol, D-81377 Munich, Germany
关键词
Pulley system; Rotator interval; Dislocation; Long head biceps tendon; MRI; Functional studies; ROTATOR INTERVAL; SUBSCAPULARIS TENDON; SHOULDER; IMPINGEMENT; ANATOMY; LESIONS;
D O I
10.1007/s00402-013-1865-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To evaluate the kinetic amplitude and direction of the long head of the biceps tendon (LHB) within the pulley and the proximal bicipital groove, we performed a 3T-magnetic resonance-throwing motion analysis. This prospective study was performed on a 3T-MRI scanner. A T2-weighted-3D sequence in three specific positions of throwing motion of the dominant shoulder was performed under isometric 5 N loading conditions or without loading, respectively. Measurements were performed in high (140A degrees) abduction/external rotation, medium (110A degrees) abduction/external rotation and low (45A degrees) adduction-flexion/internal rotation. Multiplanar rotational reconstructions along the LHB in the bicipital groove allowed for the localization of the LHB including the degree of motion in the three most proximal slices. 12 healthy volunteers (age 22-34 years) were enrolled. Adduction led to an anterior deviation of the LHB within the bicipital groove. Loading conditions in medium (110A degrees) elevation/external rotation furthermore led to a significant anterior deviation of the LHB. Our findings support the thesis that pulley lesions result from movements of the LHB especially in extreme positions during throwing/overhead activities. Load application in the medium (110A degrees) elevation/external rotation position might enable a better evaluation of patients with dedicated pulley lesions. These results need further evaluation in larger study cohorts and in patients with dedicated rotator cuff lesions, which will be the focus of ongoing studies.
引用
收藏
页码:1719 / 1725
页数:7
相关论文
共 46 条
  • [41] 3D imaging has good specificity but poor sensitivity for the diagnosis of pathologies of the long head of the biceps: a systematic review and meta-analysis
    Matthieu Lalevée
    Floris van Rooij
    Luca Nover
    Ankitha Kumble
    Mo Saffarini
    Olivier Courage
    Knee Surgery, Sports Traumatology, Arthroscopy, 2022, 30 : 2510 - 2520
  • [42] A Comparative Study on Arthroscopic Superior Capsular Reconstruction Using Fascia Lata Autograft With and Without Long Head of the Biceps Tendon Augmentation: Two-Year Patient-Reported Outcomes and Radiographic Analysis
    Cheng, You-Hung
    Wu, Chun-Te
    Chiu, Chih-Hao
    Hsu, Kuo-Yao
    Chang, Shih-Sheng
    Chan, Yi-Sheng
    Chen, Alvin Chao-Yu
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2024, 12 (10)
  • [43] Lipofibromatous hamartoma of the median nerve: 3T MRI evaluation by constrained spherical deconvolution analysis
    Arrigo, Alessandro
    Gaeta, Michele
    Calamuneri, Alessandro
    Mormina, Enricomaria
    Marino, Silvia
    d'Alcontres, Francesco Stagno
    Longo, Marcello
    Granata, Francesca
    NEURORADIOLOGY JOURNAL, 2018, 31 (04) : 445 - 448
  • [44] Comparative evaluation of non-contrast CAIPIRINHA-VIBE 3T-MRI and multidetector CT for detection of pulmonary nodules: In vivo evaluation of diagnostic accuracy and image quality
    Dewes, Patricia
    Frellesen, Claudia
    Al-Butmeh, Firas
    Albrecht, Moritz H.
    Scholtz, Jan-Erik
    Metzger, Sarah C.
    Lehnert, Thomas
    Vogl, Thomas J.
    Wichmann, Julian L.
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (01) : 193 - 198
  • [45] Performance Evaluation of Vanilla, Residual, and Dense 2D U-Net Architectures for Skull Stripping of Augmented 3D T1-Weighted MRI Head Scans
    Pimpalkar, Anway S.
    Patole, Rashmika K.
    Kamble, Ketaki D.
    Shindikar, Mahesh H.
    BIOMEDICAL ENGINEERING SCIENCE AND TECHNOLOGY, ICBEST 2023, 2024, 2003 : 131 - 142
  • [46] 3T non-injected phase-contrast MRI sequences for the mapping of the external carotid branches: In vivo radio-anatomical pilot study for feasibility analysis
    Bettoni, Jeremie
    Page, Gwenael
    Salsac, Anne-Virginie
    Constans, Jean-Marc
    Testelin, Sylvie
    Devauchelle, Bernard
    Baledent, Olivier
    Dakpe, Stephanie
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (01) : 98 - 106