In vivo evaluation of the kinematics of the long head of the biceps tendon within the pulley: A 3 T MRI motion analysis

被引:2
|
作者
Beitzel, K. [1 ,2 ]
Kirchhoff, C. [3 ]
Beitzel, K. I. [4 ]
Reiser, M. F. [4 ]
Kirchhoff, S. [4 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Orthoped & Sports Orthoped, D-80290 Munich, Germany
[2] Trauma Ctr Murnau, Dept Trauma & Orthoped Surg, Murnau, Germany
[3] Tech Univ Munich, Klinikum Rechts Isar, Dept Trauma Surg, D-80290 Munich, Germany
[4] Klinikum Ludwig Maximilians Univ Munchen, Inst Clin Radiol, D-81377 Munich, Germany
关键词
Pulley system; Rotator interval; Dislocation; Long head biceps tendon; MRI; Functional studies; ROTATOR INTERVAL; SUBSCAPULARIS TENDON; SHOULDER; IMPINGEMENT; ANATOMY; LESIONS;
D O I
10.1007/s00402-013-1865-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To evaluate the kinetic amplitude and direction of the long head of the biceps tendon (LHB) within the pulley and the proximal bicipital groove, we performed a 3T-magnetic resonance-throwing motion analysis. This prospective study was performed on a 3T-MRI scanner. A T2-weighted-3D sequence in three specific positions of throwing motion of the dominant shoulder was performed under isometric 5 N loading conditions or without loading, respectively. Measurements were performed in high (140A degrees) abduction/external rotation, medium (110A degrees) abduction/external rotation and low (45A degrees) adduction-flexion/internal rotation. Multiplanar rotational reconstructions along the LHB in the bicipital groove allowed for the localization of the LHB including the degree of motion in the three most proximal slices. 12 healthy volunteers (age 22-34 years) were enrolled. Adduction led to an anterior deviation of the LHB within the bicipital groove. Loading conditions in medium (110A degrees) elevation/external rotation furthermore led to a significant anterior deviation of the LHB. Our findings support the thesis that pulley lesions result from movements of the LHB especially in extreme positions during throwing/overhead activities. Load application in the medium (110A degrees) elevation/external rotation position might enable a better evaluation of patients with dedicated pulley lesions. These results need further evaluation in larger study cohorts and in patients with dedicated rotator cuff lesions, which will be the focus of ongoing studies.
引用
收藏
页码:1719 / 1725
页数:7
相关论文
共 46 条
  • [1] In vivo evaluation of the kinematics of the long head of the biceps tendon within the pulley: A 3 T MRI motion analysis
    K. Beitzel
    C. Kirchhoff
    K. I. Beitzel
    M. F. Reiser
    S. Kirchhoff
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 1719 - 1725
  • [2] Subpectoral tenodesis of the long head of the biceps tendon for pathologies of the long head of the biceps tendon and the biceps pulley
    Braun, S.
    Minzlaff, P.
    Imhoff, A. B.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2012, 24 (06): : 479 - 485
  • [3] Correlation between the morphological features of the biceps groove and injuries to the biceps pulley and the long head tendon of the biceps
    Tang, Xiaoye
    Zhang, Jialu
    Zhang, Jiechao
    He, Yong
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [4] MRI morphological evaluation of humeral head bone profile inside region of the biceps pulley reflection
    Fischetti, Michele
    Stoppino, Luca Pio
    Petrera, Miriana Rosaria
    Francavilla, Alessia
    Vinci, Roberta
    Zappia, Marcello
    Macarini, Luca
    SKELETAL RADIOLOGY, 2022, 51 (10) : 2017 - 2025
  • [5] Assessment of instability of the long head of the biceps tendon by MRI
    Charles E. Spritzer
    Andrew J. Collins
    Andrew Cooperman
    Kevin P. Speer
    Skeletal Radiology, 2001, 30 : 199 - 207
  • [6] Assessment of instability of the long head of the biceps tendon by MRI
    Spritzer, CE
    Collins, AJ
    Cooperman, A
    Speer, KP
    SKELETAL RADIOLOGY, 2001, 30 (04) : 199 - 207
  • [7] Diagnostic accuracy of 3T conventional shoulder MRI in the detection of the long head of the biceps tendon tears associated with rotator cuff tendon tears
    Lee, Ro Woon
    Choi, Soo-Jung
    Lee, Man Ho
    Ahn, Jae Hong
    Shin, Dong Rock
    Kang, Chae Hoon
    Lee, Ki Won
    SKELETAL RADIOLOGY, 2016, 45 (12) : 1705 - 1715
  • [8] Arthroscopic diagnosis of long head of biceps tendon instability in refractory anterior shoulder pain: A comparison study between pulley tear and non-tear lesions
    Kao, Jo-Ting
    Chiu, Chih-Hao
    Hsu, Kuo-Yau
    Chang, Shih-Sheng
    Chan, Yi-Sheng
    Chen, Alvin Chao-Yu
    BIOMEDICAL JOURNAL, 2023, 46 (01) : 163 - 169
  • [9] The Long Head of the Biceps Tendon Has Minimal Effect on In Vivo Glenohumeral Kinematics A Biplane Fluoroscopy Study
    Giphart, J. Erik
    Elser, Florian
    Dewing, Christopher B.
    Torry, Michael R.
    Millett, Peter J.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2012, 40 (01) : 202 - 212
  • [10] Long head biceps tendon instability: diagnostic performance of known and new MRI diagnostic signs
    Zappia, Marcello
    Ascione, Francesco
    Di Pietto, Francesco
    Fischetti, Michele
    Romano, Alfonso M.
    Castagna, Alessandro
    Brunese, Luca
    SKELETAL RADIOLOGY, 2021, 50 (09) : 1863 - 1871