Performance of different preconcentration columns used in sequential injection analysis and inductively coupled plasma-mass spectrometry for multielemental determination in seawater

被引:59
作者
Jiménez, MS [1 ]
Velarte, R [1 ]
Castillo, JR [1 ]
机构
[1] Univ Zaragoza, Analyt Spect & Sensors Grp, Dept Analyt Chem, E-50009 Zaragoza, Spain
关键词
inductively coupled plasma-mass spectrometry (ICP-MS); saline sample analysis; multielemental determination; sequential injection analysis (SIA); on-line column preconcentration;
D O I
10.1016/S0584-8547(01)00401-3
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A simple, versatile and economical method of sequential injection analysis and inductively coupled plasma-mass spectrometry with matrix removal in two different ion-exchange resins for the determination of Al, As, Co, Cu, Mn, Mo, Ni, Pb and V is reported. The resins used, both of which contain the iminodiacetic acid functional group, were Chelex 100 and Metpac CC-1. With both resins, a matrix removal step (alkaline and alkaline-earth metals) with ammonium acetate is required before elution of the analytes with 2 M HNO3. The procedure was validated by analyzing CASS-3 seawater reference material and good agreement was found with the certified values. Precision (n = 8) for the nine elements was in the range 0.8-4.9% for the Chelex 100 column and the recoveries ranged from 87.4 to 107.9%, except for Cu (78.7%) and Pb (74.9%), owing to the formation of hydroxides. For the Metpac CC-1 column, precision for the nine elements was in the range 1.2-7.1% and the recoveries between 91.7 and 109.3% except for Al (127.2%), Co (118.5%) and Ni (127.5%) due to contamination problems. (C) 2002 Elsevier Science B.V All rights reserved.
引用
收藏
页码:391 / 402
页数:12
相关论文
共 39 条
[1]   Semiquantitative elemental analysis of water samples using double focusing inductively coupled plasma mass spectrometry [J].
Bayon, MM ;
Alonso, JIG ;
Sanz-Medel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (09) :1027-1032
[2]   Trace metal analysis of natural waters and biological samples by axial inductively coupled plasma time of flight mass spectrometry (ICP-TOFMS) with flow injection on-line adsorption preconcentration using a knotted reactor [J].
Benkhedda, K ;
Infante, HG ;
Ivanova, E ;
Adams, FC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (10) :1349-1356
[3]   DETERMINATION OF TRACE-ELEMENTS IN SEA-WATER BY ION CHROMATOGRAPHY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
BETTINELLI, M ;
SPEZIA, S .
JOURNAL OF CHROMATOGRAPHY A, 1995, 709 (02) :275-281
[4]   DETERMINATION OF TRACE-METALS IN SEA-WATER AND THE ONLINE REMOVAL OF MATRIX INTERFERENCES BY FLOW-INJECTION WITH INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRIC DETECTION [J].
BLOXHAM, MJ ;
HILL, SJ ;
WORSFOLD, PJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (09) :935-938
[5]   DETERMINATION OF ARSENIC IN SAMPLES WITH HIGH CHLORIDE CONTENT BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BRANCH, S ;
EBDON, L ;
FORD, M ;
FOULKES, M ;
ONEILL, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (02) :151-154
[6]  
da Silva MAM, 2000, SPECTROCHIM ACTA B, V55, P803
[7]   DETERMINATION OF TRACE-METALS IN CONCENTRATED BRINES USING INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY ONLINE PRECONCENTRATION AND MATRIX ELIMINATION WITH FLOW-INJECTION [J].
EBDON, L ;
FISHER, A ;
HANDLEY, H ;
JONES, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (07) :979-981
[8]   Determination of copper, cadmium, manganese and lead in saline water with flow injection and atom trapping atomic absorption spectrometry [J].
Ellis, LA ;
Roberts, DJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (07) :631-634
[10]   AN ONLINE METHOD FOR THE DETERMINATION OF LEAD AND LEAD-ISOTOPE RATIOS IN FRESH AND SALINE WATERS BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
HALICZ, L ;
LAM, JWH ;
MCLAREN, JW .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1994, 49 (07) :637-647