The meson target stations and the high power spallation neutron source SINQ at PSI

被引:6
|
作者
Kiselev, D. [1 ]
Baumann, P. [1 ]
Blau, B. [1 ]
Geissmann, K. [1 ]
Laube, D. [1 ]
Reiss, T. [1 ]
Sobbia, R. [1 ]
Strinning, A. [1 ]
Talanov, V. [1 ]
Wohlmuther, M. [1 ]
机构
[1] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
关键词
High power target; Meson production; Spallation neutron source;
D O I
10.1007/s10967-015-3999-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The Paul Scherrer Institut operates two meson graphite targets, Target M and Target E, for creating the world's most intense pion and muon beams by using 590 MeV protons and c.w. beam currents of up to 2.4 mA (=1.4 MW). The energy deposit on Target E is 20 kW mA(-1). The proton beam feeds also the spallation neutron source SINQ, which operates in DC mode and produces thermal and cold neutrons. The SINQ target consists of a bundle of lead filled Zircaloy tubes. In this report the continuous developments of both target facilities and their operation are presented.
引用
收藏
页码:769 / 775
页数:7
相关论文
共 50 条
  • [1] The meson target stations and the high power spallation neutron source SINQ at PSI
    D. Kiselev
    P. Baumann
    B. Blau
    K. Geissmann
    D. Laube
    T. Reiss
    R. Sobbia
    A. Strinning
    V. Talanov
    M. Wohlmuther
    Journal of Radioanalytical and Nuclear Chemistry, 2015, 305 : 769 - 775
  • [2] Target development for the SINQ high-power neutron spallation source
    Wagner, W
    HIGH INTENSITY AND HIGH BRIGHTNESS HADRON BEAMS, 2002, 642 : 119 - 121
  • [3] SINQ - The spallation neutron source, a new research facility at PSI
    Fischer, WE
    PHYSICA B, 1997, 234 : 1202 - 1208
  • [4] SINQ - the spallation neutron source, a new research facility at PSI
    Fischer, W.E.
    Physica B: Condensed Matter, 1997, 234-236 : 1202 - 1208
  • [5] SINQ - The spallation neutron source, a new research facility at PSI
    Fischer, WE
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY - PROCEEDINGS OF THE FOURTEENTH INTERNATIONAL CONFERENCE, PTS 1 AND 2, 1997, (392): : 1119 - 1122
  • [6] Target operation at the high-power neutron spallation source SINQ - Safety and reliability issues
    Wagner, W
    WORKSHOP ON RADIATION PROTECTION ISSUES RELATED TO RADIOACTIVE ION-BEAM FACILITIES (SAFERIB), PROCEEDINGS, 2003, 2003 (04): : 15 - 25
  • [7] ON THE NEUTRONICS OF SINQ, A CONTINUOUS SPALLATION NEUTRON SOURCE
    FISCHER, WE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 249 (01): : 116 - 122
  • [8] Radiochemical separation of 7Be from the cooling water of the neutron spallation source SINQ at PSI
    Schumann, D.
    Ayranov, M.
    Stowasser, T.
    Gialanella, L.
    di Leva, A.
    Romano, M.
    Schuermann, D.
    RADIOCHIMICA ACTA, 2013, 101 (08) : 509 - 514
  • [9] THE SPALLATION-NEUTRON-SOURCE PROJECT SINQ
    ATCHISON, F
    FISCHER, WE
    PEPIN, M
    TAKEDA, Y
    TSCHALAER, C
    FURRER, A
    PHYSICA B & C, 1986, 136 (1-3): : 97 - 99
  • [10] Materials issues of the SINQ high-power spallation target
    Wagner, Werner
    Vontobel, Peter
    Dai, Yong
    INTERNATIONAL JOURNAL OF MATERIALS RESEARCH, 2011, 102 (09) : 1101 - 1105