Axiomatic approach for quantification of image resolution

被引:19
作者
Wang, G [1 ]
Li, Y
机构
[1] Univ Iowa, Dept Radiol, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Math, Iowa City, IA 52242 USA
关键词
axiomatic approach; image noise; image resolution; imaging system; point spread function;
D O I
10.1109/97.789603
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Image resolution is the primary parameter for performance characterization of any imaging system. In this work, we present an axiomatic approach for quantification of image resolution, and demonstrate that a good image resolution measure should be proportional to the standard deviation of the point spread function of an imaging system.