Identification of independent risk factors for restenosis following bare-metal stent implantation: Role of bare-metal stents in the era of drug-eluting stents

被引:9
作者
Park, Chang-Bum [1 ]
Park, Hoon-Ki [2 ]
机构
[1] Kyung Hee Univ, Kyung Hee Univ Hosp Gangdong, Dept Internal Med, Grad Sch Med, Seoul 134727, South Korea
[2] Seoul Vet Hosp, Dept Internal Med, Seoul 134791, South Korea
关键词
stent; coronary angioplasty; restenosis; PERCUTANEOUS CORONARY INTERVENTION; ANGIOGRAPHIC RESTENOSIS; PREDICTORS; CARDIOLOGY; PLACEMENT;
D O I
10.3892/etm.2013.1212
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
In the era of drug-eluting stents (DESs), the ability of clinicians to predict which patients have a low risk of coronary restenosis following bare-metal stent (BMS) implantion is likely to be of benefit. The study population consisted of 2,711 patients who underwent BMS implantation in 3,770 lesions between 1995 and 2004. With clinical and 6 month follow-up angiographic data, we retrospectively sought to identify the independent risk predictors of restenosis, applied a previously proposed prediction model and assessed the characteristics of patients with a low likelihood of coronary restenosis within 6 months of BMS implantation. A 6-month follow-up coronary angiography was performed in 65.0% of the patients who had undergone the BMS implantation and the rate of restenosis was 26.6%. Using multivariate analysis, diabetes [odds ratio (OR), 1.294; 95% confidence interval (CI), 1.094-1.483; P=0.005], current smoking (OR, 1.294; 95% CI, 1.094-1.483; P=0.002), a reference vessel diameter of <3.25 mm (OR, 1.238; 95% CI, 1.021-1.501; P<0.001), a lesion length of >30 mm (OR, 1.645; 95% CI, 1.336-2.026; P<0.001), ostial lesion (OR, 1.858; 95% CI, 1.437-2.402; P<0.001), post-stenting minimal luminal diameter (OR, 0.576; 95% CI, 0.484-0.685; P<0.001) and bifurcation lesion (OR, 1.353; 95% CI, 1.070-1.711; P=0.012) were identified as significant independent predictors of restenosis. However, the accuracy of the prediction obtained with the current model, which used the clinical and angiographic variables correlated with the risk of restenosis, was poor. Various clinical and angiographic independent risk variables were revealed to be correlated with the risk of restenosis following BMS implantation in the present large dataset. Certain groups of patients with a relatively low risk of restenosis may be considered for BMS implantation as an alternative to DESs. However, the prediction models used at present are incomplete and further studies are required.
引用
收藏
页码:840 / 846
页数:7
相关论文
共 19 条
[1]   Chronic stable angina [J].
Abrams, J .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (24) :2524-2533
[2]  
Andrikopoulos GK, 2002, CIRCULATION, V105, pE55
[3]   Predictors of restenosis after coronary stent implantation [J].
Bauters, C ;
Hubert, E ;
Prat, A ;
Bougrimi, K ;
Van Belle, E ;
McFadden, EP ;
Amouyel, P ;
Lablanche, JM ;
Bertrand, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (06) :1291-1298
[4]   Impact of smoking on clinical and angiographic restenosis after percutaneous coronary intervention - Another smoker's paradox? [J].
Cohen, DJ ;
Doucet, M ;
Cutlip, DE ;
Ho, KKL ;
Popma, JJ ;
Kuntz, RE .
CIRCULATION, 2001, 104 (07) :773-778
[5]   Clinical restenosis after coronary stenting: Perspectives from multicenter clinical trials [J].
Cutlip, DE ;
Chauhan, MS ;
Baim, DS ;
Ho, KKL ;
Popma, JJ ;
Carrozza, JP ;
Cohen, DJ ;
Kuntz, RE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (12) :2082-2089
[6]   Reference chart derived from post-stent-implantation intravascular ultrasound predictors of 6-month expected restenosis on quantitative coronary angiography [J].
de Feyter, PJ ;
Kay, P ;
Disco, C ;
Serruys, PW .
CIRCULATION, 1999, 100 (17) :1777-1783
[7]   Real-world bare metal stenting: Identification of patients at low or very low risk of 9-month coronary revascularization [J].
Ellis, SG ;
Bajzer, CT ;
Bhatt, DL ;
Brener, SJ ;
Whitlow, PL ;
Lincoff, AM ;
Moliterno, DJ ;
Raymond, RE ;
Tuzcu, EM ;
Franco, I ;
Dushman-Ellis, S ;
Lander, KJ ;
Schneider, JP ;
Topol, EJ .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 63 (02) :135-140
[8]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[9]  
Green Conaway D, 2002, CIRCULATION, V106, P11
[10]   Predictive factors for early cardiac events and angiographic restenosis after coronary stent placement in small coronary arteries [J].
Hausleiter, J ;
Kastrati, A ;
Mehilli, J ;
Schühlen, H ;
Pache, J ;
Dotzer, F ;
Dirschinger, J ;
Schömig, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (05) :882-889