Multicomponent flow injection based analysis with diode array detection and partial least squares multivariate calibration evaluation. Rapid determination of Ca(II) and Mg(II) in waters and dialysis liquids

被引:28
作者
Hernandez, O
Jimenez, F
Jimenez, AI
Arias, JJ
Havel, J
机构
[1] UNIV LA LAGUNA,DEPT ANALYT CHEM FOOD SCI & TOXICOL,E-38204 LA LAGUNA,TENERIFE,SPAIN
[2] MASARYK UNIV,FAC SCI,DEPT ANALYT CHEM,CR-61137 BRNO,MORAVIA,CZECH REPUBLIC
关键词
multicomponent analysis; flow injection; partial least squares multivariate calibration;
D O I
10.1016/0003-2670(95)00528-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow injection analysis (FIA) with multiwavelength scanning of the FIA peaks using a diode array detector (DAD) has been combined with a multivariate calibration approach applying the partial least squares (PLS) method for the data evaluation. In this way, various side effects like dilution of the reagent, high blank absorbance changes due to the pH gradient throughout the peak and/or the other interferences can be accounted for. Thus, even with a simple FIA manifold instrumentation the satisfactory results of multicomponent analysis are obtained. The method described has been checked on analysis of binary (Ca and Mg) and ternary (Ca, Mg and Cu) mixtures with pyridylazo resorcinol (PAR) as reagent and applied for rapid determination of calcium and magnesium in dialysis liquids and waters.
引用
收藏
页码:177 / 183
页数:7
相关论文
共 16 条
[1]   DIODE-ARRAY DETECTORS IN FLOW-INJECTION ANALYSIS - MIXTURE RESOLUTION BY MULTI-WAVELENGTH ANALYSIS [J].
BLANCO, M ;
GENE, J ;
ITURRIAGA, H ;
MASPOCH, S ;
RIBA, J .
TALANTA, 1987, 34 (12) :987-993
[2]   USE OF DIODE-ARRAY DETECTORS FOR THE SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF CALCIUM AND MAGNESIUM BY FLOW-INJECTION [J].
BLANCO, M ;
COELLO, J ;
GENE, J ;
ITURRIAGA, H ;
MASPOCH, S .
ANALYTICA CHIMICA ACTA, 1989, 224 (01) :23-30
[3]   MULTICOMPONENT ANALYSIS OF CONCENTRATED-SOLUTIONS BY FLOW-INJECTION ANALYSIS WITH ZONE SAMPLING AND PARTIAL LEAST-SQUARES RESOLUTION [J].
BLANCO, M ;
COELLO, J ;
ITURRIAGA, H ;
MASPOCH, S ;
REDON, M ;
RIBA, J .
ANALYTICA CHIMICA ACTA, 1992, 259 (02) :219-224
[4]   SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF CALCIUM AND MAGNESIUM IN WATER [J].
GOMEZ, E ;
ESTELA, JM ;
CERDA, V .
ANALYTICA CHIMICA ACTA, 1991, 249 (02) :513-518
[5]   EVALUATION OF MULTICOMPONENT KINETIC-ANALYSIS DATA BY A PARTIAL LEAST-SQUARES CALIBRATION METHOD [J].
HAVEL, J ;
JIMENEZ, F ;
BAUTISTA, RD ;
LEON, JJA .
ANALYST, 1993, 118 (11) :1355-1360
[6]  
HAVEL J, 1991, 2 SCAND S CHEM BERG
[7]   PARTIAL LEAST-SQUARES METHOD FOR SPECTROFLUORIMETRIC ANALYSIS OF MIXTURES OF HUMIC-ACID AND LIGNINSULFONATE [J].
LINDBERG, W ;
PERSSON, JA ;
WOLD, S .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :643-648
[8]   EVALUATION OF POTENTIOMETRIC ACID-BASE TITRATIONS BY PARTIAL-LEAST-SQUARES CALIBRATION [J].
LINDBERG, W ;
KOWALSKI, B .
ANALYTICA CHIMICA ACTA, 1988, 206 (1-2) :125-135
[9]  
Lorber A., 1987, J CHEMOMETR, V1, P19, DOI DOI 10.1002/CEM.1180010105
[10]   MULTICOMPONENT DETERMINATIONS IN FLOW SYSTEMS BY PARTIAL LEAST-SQUARES MODELING [J].
LUKKARI, I ;
LINDBERG, W .
ANALYTICA CHIMICA ACTA, 1988, 211 (1-2) :1-10