Real-Time Two-Dimensional Imaging of Microbubble Cavitation

被引:1
|
作者
Vignon, Francois [1 ]
Shi, W. T. [1 ]
Powers, J. E. [2 ]
Liu, J. [3 ,4 ]
Drvol, L. [4 ]
Lof, J. [4 ]
Everbach, C. [5 ]
Gao, S. [4 ]
Xie, F. [4 ]
Porter, T.
机构
[1] Philips Res N Amer, Briarcliff Manor, NY USA
[2] Philips Hlthcare, Bothell, WA USA
[3] Univ Nebraska, Lincoln, NE USA
[4] Univ Nebraska, Med Ctr, Omaha, NE USA
[5] Swarthmore Coll, Swarthmore, PA USA
关键词
Ultrasound contrast agents; Cavitation; Treatment planning; Treatment monitoring; Sonothrombolysis; Stroke; ULTRASOUND;
D O I
10.1063/1.4757369
中图分类号
O59 [应用物理学];
学科分类号
摘要
Ultrasound cavitation of microbubble contrast agents has a potential for therapeutic applications, including sonothrombolysis in acute ischemic stroke. For safety, efficacy, and reproducibility of treatment, it is critical to evaluate the cavitation state (e. g. stable versus inertial forms of cavitation) and intensity in and around a treatment area. Acoustic Passive Cavitation Detectors (PCDs) have been used but do not provide spatial information. This paper presents a prototype of a 2D cavitation imager capable of producing images of the dominant cavitation state and intensity in a region of interest at a frame rate of 0.6Hz. The system is based on a modified ultrasound scanner (iE33, Philips) with a sector imaging probe (S5-1). Cavitation imaging is based on the spectral analysis of the acoustic signal radiated by the cavitating microbubbles: ultraharmonics of the excitation frequency indicate stable cavitation, while noise bands indicate inertial cavitation. The system demonstrates the capability to robustly identify stable and inertial cavitation thresholds of Definity microbubbles (Lantheus) in a vessel phantom through 3 ex-vivo human temporal bones, as well as to spatially map cavitation activities.
引用
收藏
页码:407 / 413
页数:7
相关论文
共 50 条
  • [1] Progress in two-dimensional arrays for real-time volumetric imaging
    Light, ED
    Davidsen, RE
    Fiering, JO
    Hruschka, TA
    Smith, SW
    ULTRASONIC IMAGING, 1998, 20 (01) : 1 - 15
  • [2] Real-time Two-Dimensional Temperature Imaging Using Ultrasound
    Liu, Dalong
    Ebbini, Emad S.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 1971 - +
  • [3] REAL-TIME TWO-DIMENSIONAL ECHOCARDIOGRAPHY
    SAHN, DJ
    JOURNAL OF PEDIATRICS, 1981, 99 (02): : 175 - 185
  • [4] REAL-TIME TWO-DIMENSIONAL IMAGING BASED ON QUANTITATIVE INTEGRATED BACKSCATTER
    THOMAS, LJ
    BARZILAI, B
    WICKLINE, SA
    GESSLER, CJ
    SOBEL, BE
    PEREZ, JE
    MILLER, JG
    ULTRASONIC IMAGING, 1986, 8 (01) : 36 - 36
  • [6] Real-time measurement of two-dimensional birefringence
    Itoh, K
    Ohkawa, T
    Zhu, YC
    Takada, T
    Maeno, T
    INTERNATIONAL SYMPOSIUM ON POLARIZATION ANALYSIS AND APPLICATIONS TO DEVICE TECHNOLOGY, 1996, 2873 : 33 - 36
  • [7] Real-time two-dimensional terahertz tomography
    Yasui, T
    Yasuda, T
    Araki, T
    IRMMW-THz2005: The Joint 30th International Conference on Infrared and Millimeter Waves and 13th International Conference on Terahertz Electronics, Vols 1 and 2, 2005, : 580 - 581
  • [8] REAL-TIME COMPUTERIZATION OF TWO-DIMENSIONAL ECHOCARDIOGRAPHY
    GARCIA, E
    GUERET, P
    BENNETT, M
    CORDAY, E
    ZWEHL, W
    MEERBAUM, S
    CORDAY, S
    SWAN, HJC
    BERMAN, D
    AMERICAN HEART JOURNAL, 1981, 101 (06) : 783 - 792
  • [9] Thromboembolism in real-time two-dimensional echocardiography
    Davis, GK
    Fisk, C
    Talwar, S
    CIRCULATION, 2003, 107 (01) : E1 - E1
  • [10] TWO-DIMENSIONAL, REAL-TIME ECHOCARDIOGRAPHY IN THE HORSE
    CARLSTEN, JC
    VETERINARY RADIOLOGY, 1987, 28 (03): : 76 - 87