Pulsatility role in cylinder flow dynamics at low Reynolds number

被引:18
作者
Qamar, Adnan [1 ]
Samtaney, Ravi [1 ]
Bull, Joseph L. [2 ]
机构
[1] King Abdullah Univ Sci & Technol KAUST, Thuwal 239556900, Saudi Arabia
[2] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
ARTIFICIAL-LUNG; CIRCULAR-CYLINDER; MASS-TRANSPORT; BLOOD-FLOW; MODEL;
D O I
10.1063/1.4740504
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
We present dynamics of pulsatile flow past a stationary cylinder characterized by three non-dimensional parameters: the Reynolds number (Re), non-dimensional amplitude (A) of the pulsatile flow velocity, and Keulegan-Carpenter number (KC = U-o/D omega(c)). This work is motivated by the development of total artificial lungs (TAL) device, which is envisioned to provide ambulatory support to patients. Results are presented for 0.2 <= A <= 0.6 and 0.57 <= KC <= 2 at Re = 5 and 10, which correspond to the operating range of TAL. Two distinct fluid regimes are identified. In both regimes, the size of the separated zone is much greater than the uniform flow case, the onset of separation is function of KC, and the separation vortex collapses rapidly during the last fraction of the pulsatile cycle. The vortex size is independent of KC, but with an exponential dependency on A. In regime I, the separation point remains attached to the cylinder surface. In regime II, the separation point migrates upstream of the cylinder. Two distinct vortex collapse mechanisms are observed. For A < 0.4 and all KC and Re values, collapse occurs on the cylinder surface, whereas for A > 0.4 the separation vortex detaches from the cylinder surface and collapses at a certain distance downstream of the cylinder. The average drag coefficient is found to be independent of A and KC, and depends only on Re. However, for A > 0.4, for a fraction of the pulsatile cycle, the instantaneous drag coefficient is negative indicating a thrust production. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4740504]
引用
收藏
页数:7
相关论文
共 18 条
  • [1] VISCOUS OSCILLATORY FLOW ABOUT A CIRCULAR-CYLINDER AT SMALL TO MODERATE STROUHAL NUMBER
    BADR, HM
    DENNIS, SCR
    KOCABIYIK, S
    NGUYEN, P
    [J]. JOURNAL OF FLUID MECHANICS, 1995, 303 : 215 - 232
  • [2] Pulsatile flow and mass transport over an array of cylinders: Gas transfer in a cardiac-driven artificial lung
    Chan, KY
    Fujioka, H
    Bartlett, RH
    Hirschl, RB
    Grotberg, JB
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (01): : 85 - 96
  • [3] Design of an artificial lung compliance chamber for pulmonary replacement
    Haft, JW
    Bull, JL
    Rose, R
    Katsra, J
    Grotberg, JB
    Bartlett, RH
    Hirschl, RB
    [J]. ASAIO JOURNAL, 2003, 49 (01) : 35 - 40
  • [4] Results of an artificial-lung survey to lung transplant program directors
    Haft, JW
    Griffith, BP
    Hirschl, RB
    Bartlett, RH
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2002, 21 (04) : 467 - 473
  • [6] A NUMERICAL STUDY OF OSCILLATING FLOW AROUND A CIRCULAR-CYLINDER
    JUSTESEN, P
    [J]. JOURNAL OF FLUID MECHANICS, 1991, 222 : 157 - 196
  • [7] Pulsatile flow past a cylinder: An experimental-model of flow in an artificial lung
    Lin, Yu-chun
    Brant, David O.
    Bartlett, Robert H.
    Hirschl, Ronald B.
    Bull, Joseph L.
    [J]. ASAIO JOURNAL, 2006, 52 (06) : 614 - 623
  • [8] An investigation of pulsatile flow past two cylinders as a model of blood flow in an artificial lung
    Lin, Yu-chun
    Khanafer, Khalil M.
    Bartlett, Robert H.
    Hirschl, Ronald B.
    Bull, Joseph L.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (15-16) : 3191 - 3200
  • [9] Obstructive lung disease and low lung function in adults in the United States -: Data from the National Health and Nutrition Examination Survey, 1988-1994
    Mannino, DM
    Gagnon, RC
    Petty, TL
    Lydick, E
    [J]. ARCHIVES OF INTERNAL MEDICINE, 2000, 160 (11) : 1683 - 1689
  • [10] Pulmonary arterial resistance: Noninvasive measurement with indexes of pulmonary flow estimated at velocity-encoded MR imaging - Preliminary experience
    Mousseaux, E
    Tasu, JP
    Jolivet, O
    Simonneau, G
    Bittoun, J
    Gaux, JC
    [J]. RADIOLOGY, 1999, 212 (03) : 896 - 902